Page 3: ...any electronic medium or machine readable form without prior consent in writing from Faroudja Laboratories Inc The Faroudja name logo and Picture Plus are registered trademarks of Faroudja Inc Specifications subject to change without notice All Rights Reserved The Faroudja Laboratories NR Series is covered by the following United States patents 4 030 121 4 179 705 4 240 105 4 262 304 4 847 681 4 8...

Page 4: ...ot needed As hot air raises out of the top vent cool air is drawn in from the bottom These vents must not be blocked When rack mounted a minimum of 1 75 1 rack unit height of free space is required above and below the unit to allow for proper cooling A forced air fan should be added to the rack installation if power amps are located in the same air space REAR PANEL I O Inputs 1 S Video 4 Pin DIN 2...

Page 5: ... and professional cameras Will not accept progressive or HDTV signals 4 High scan rate sources such as HDTV signals or computers as a pass through to the projector YPrPb from HDTV sources can be transcoded to RGBHV on the output OUTPUTS 15 D15F connector for use with computer moni tors or to a second display device 16 BNC connectors for main output to display devices For YPrPb outputs use Red Pr G...

Page 6: ...te on power up and the current Function or Value selected 17 Function Up Down Cycles up or down through the available control Functions 18 Value Up Down Adjusts the levels or changes settings of the Function selected 19 Custom Presets Four presets per input 10 Enter Press to store presets or to enter menus 11 Factory Preset Recalls all settings to Factory levels Pressing once while adjusting a set...

Page 7: ...e angle screen Wide 4 3 choose this when the projector is 4 3 only and the screen is Widescreen Not available on units scanning at rates below 720p Example A digital projector that is 4 3 only with a wide angle screen Storing the Screen Shape Note The Factory Default screen shape for all NRS units is 4 3 If that is the desired screen shape to be used the following steps are not required Select an ...

Page 8: ...g Use posi tioning controls in the display first if available Pass RGB Input Sync Sync on Green Ext Sync High Low Low sync is used with PAL sources where com posite video is applied as sync with RGB Composite Sync on H On Off Sync on Green On Off Default Comp Sync on H and Sync on Green Functions are only available if RGB output is selected Output Format RGB Default YCrCb YPrPb Note On 540p and 16...

Page 9: ...to select an adjustment Use Value to adjust The main menu drops away and a single line menu appears Use the Function keys return to the drop down menu Press Menu to recall the main index Press Menu again to remove OSD The OSD consists of four index tabs The Functions available for each index are listed below Formats Input Select Video S Video YCrCb RGB PassThru Aspect Ratio 4 3 Letterbox Anamorphi...

Page 10: ... to adjust the image position and edge blanking It is recommended to adjust sizing and blanking in the display device first This should be done by a qualified technician Position Horizontal Vertical Blanking Left Right Top Bottom These patterns are used to setup and align the image This should be done by a qualified techni cian only Pattern On Off Select Off Cr Ramp PLUGE Cb Ramp 100IRE Window Lum...

Page 11: ...ction 11 Red Out 12 Green Out 13 Blue Out 17 Red Gnd 18 Green Gnd 19 Blue Gnd 10 Sync Gnd 11 Sync Gnd 13 H Sync Out 14 V Sync Out Horizontal Sync NTSC 31 5KHz 37 7KHz 45KHz or 48KHz depending on model NTSC 63KHz Native Rate Series Plus only PAL 31 2KHz 37KHz 40KHz depending on model PAL 53KHz Native Rate Series Plus only 4 0 vpp TTL Vertical Sync 60Hz 50Hz 4 0 vpp TTL Composite Sync 4 0 vpp TTL Di...

Page 12: ...SDT OSD Timer 4 255 Factory 128 Default 10 C Contrast 0 255 P Pass Thru Factory 128 R Pass Thru Y Transcode T Tint 0 255 TP Internal test Pattern Factory 128 0 Off 1 100 Color Bars 2 Reverse Color Bars 3 10 step Grayscale 4 Luma Ramp 5 Cb Ramp 6 Cr Ramp 7 Green 8 Red 9 Blue 10 Convergence 11 Active Boarder 12 SMPTE Color Bars 13 100 Window 14 PLUGE K Color 0 255 IR IR Receiver Factory 128 0 Off 1 ...

Page 13: ...To turn On the unit a sequence must be used Press Power 1 On 0 Off Note The timing of the digits 1 0 must be under 25 seconds after the Power command is issued Note all sequence commands listed below should have approximately a 25 second delay between commands Input Control Input 1 Composite 2 S Video 3 YPrPb YCrCb 4 RGB 5 Pass through Aspect Ratio Control Aspect 1 4 3 2 Letterbox 3 Anamorphic IR ...

Page 14: ...repaid Faroudja s only liability with respect to products that do not meet the foregoing warranty and for which appropriate transportation arrangements have been made will be to repair or at Faroudja s option replace defective products or portions thereof THE FOREGOING WARRANTY IS IN LIEU OF ALL WARRANTIES EXPRESSED IMPLIED OR STATUTORY REGARDING THE PRODUCTS AND ALL IMPLIED WARRANTIES INCLUDING W...