LUMINA 47 

LUMINA 47 
LUMINA 47 TOUCH 

MANUAL 

VERSION C1 

 

Summary of Contents for LUMINA 47

Page 1: ...LUMINA 47 LUMINA 47 LUMINA 47 TOUCH MANUAL VERSION C1 g...

Page 2: ...d by Fancom For the latest information about product installation and operation please contact the customer service dept and or the technical service dept of the Fancom company concerned In spite of t...

Page 3: ...3 User 4 3 1 Daily management 4 3 2 Animal management 6 3 3 Settings 11 4 Installer 13 4 1 Installing the control computer 13 4 2 System 13 4 3 Setup 20 4 4 Weighing for service purposes only 20 5 Sy...

Page 4: ...uestions and support please contact the local Fancom Sales Service Center 1 3 F Central FarmManager Virtually all Fancom equipment can be controlled and managed from a central location This requires t...

Page 5: ...installation or before carrying out any maintenance to the control computer Take precautions against electrostatic discharge ESD when working on the control computer Ensure the workplace is clean and...

Page 6: ...one house with two weighing scales The Fancom weighing system consists of a computer and a maximum of two weighing scales The scales are connected to the computer which can be connected to a PC The e...

Page 7: ...rol computer The screen layout is related to the controls built into the control computer The image below is an example of the Overview This image may differ from your screen because the control compu...

Page 8: ...t and accepted weight see Overview on page 4 Nbr Read out of the number of measurements on that day Unif Readout of the uniformity percentage or covariance CV depending on the installer settings The c...

Page 9: ...ds on what has been set Nbr Readout of the number of measurements on that day or week 3 2 Animal management Animal management covers all actions which result in a different number of animals Set up an...

Page 10: ...mortality and delivered The date of the last change is shown behind each piece of information The control computer calculates the data shown as follows Number of animals present Set up Delivered Mort...

Page 11: ...do not control with the curve All control data must be entered manually The day number stays 0 during the lifecycle of the animals Day number 1 or higher control with the curve The control computer i...

Page 12: ...lso be adjusted This can be done as follows If control is manual day number 0 enter the new settings manually If control is based on the curve day number 1 or higher the control computer will automati...

Page 13: ...ll offsets are set to 0 Overview Deliver Enter delivery data as follows 1 Select the menu Animal data 2 Press the key at Deliver 3 Select one of the two options Deliver all animals To deliver all the...

Page 14: ...standard Overview tab page Curve Day Week Setting of a day week number per bending point max 24 bending points Std Setting of the corresponding theoretical weight for each bending point Overview tab...

Page 15: ...aking settings check the system time and date Overview Date Setting of the current date Time Setting of the current time Day Setting of the current day number Measuring time Setting of the measurement...

Page 16: ...nstaller can configure the control computer using the installation menu This menu also contains screens for standard system settings and diagnoses To call up the installation menu log in to the role I...

Page 17: ...number of the control computer in the network Language Setting of the program language S2S MasterSlave Master Slave setting If the control computer is included in a network only one control computer i...

Page 18: ...l request the password again if the controller is not used for a few minutes Change password EditMode Setting of a password so that only authorised users can change the user settings The password must...

Page 19: ...the control computer type FBU Data saved on one control computer can only be loaded into another control computer if both computers are of the same type In addition the set control computer numbers m...

Page 20: ...e data of the control computer SYSTEM APPLICATION 4 2 4 Communication I2 C is a communication bus used to connect printed circuit boards in the control computer e g AI 4 SYSTEM COMMUNICATION tab page...

Page 21: ...ting if the settings of the customer must be run in Simulation Mode If no IO net modules are connected the control computer doesn t give alarms during the Simulation Mode FNet is the Fancom Network Se...

Page 22: ...zero simultaneously 4 2 5 IO Test Use the Input I and Output O test menu to set the control computer to test the communication channels In the IO test menu inputs can be readout and outputs controlled...

Page 23: ...weight Display Setting whether the uniformity percentage or the covariance is to be displayed 4 4 Weighing for service purposes only These settings readouts are for service purposes only 4 4 1 Tab pag...

Page 24: ...elect Span 5 Enter the Calibration weight in the screen that appears Press Ready to calibrate the weigher with this weight Tab page Weighing will appear again In Span the calibration weight will appea...

Page 25: ...ormally afterwards If the Maximum tare is exceeded no more dosing in can take place The control computer stops followed by a loud alarm The control computer automatically determines the Maximum tare w...

Page 26: ...ication with PC Check wiring and connections I O net alarm No communication with I O modules Check wiring and connections I2C alarm No communication between internal circuit boards Check wiring and co...

Page 27: ...ge free max 2A 60Vdc 30Vac Communication I O Net for extra inputs and outputs using I O modules FNet Fancom network for intercommunication of control computers and PC connection LCC Excitation voltage...

Page 28: ...Lumina 47 Technical specifications 25 6 1 The inside of the control computer 6 2 FDP25...

Page 29: ...hnical specifications 26 6 3 IOB 0 Relay 1 Digital output Alarm relay 6 4 LCC A I2C connection to IOB B Dipswitch I2C address select fixed on address 3 dipswitch 1 2 on OFF C Weigh input 1 D Weigh inp...

Page 30: ...cable The standard cable from the load cells to the Lumina 47 is 10 metres This cable can be lengthened by maximum 40 metres When lengthening the cable follow the diagram below The standard 4 core ca...

Page 31: ...terminal resistor Example Setting the I O net terminal resistor 1 One control computer connected to two I 0 network modules using one I O net The control computer is located between the two I O netwo...

Page 32: ...anningen the Netherlands Hereby declares that the Lumina 47 Complies with the provisions of the 1 Low voltage directive 2006 95 EC according to NEN EN IEC 61010 1 2010 2 EMC directive 2004 108 EC Emis...