background image

 

MARQUE : FAGOR

REFERENCE : 2MF-2VX

CODIC : 2437953

Summary of Contents for 2MF-2VX

Page 1: ...MARQUE FAGOR REFERENCE 2MF 2VX CODIC 2437953 ...

Page 2: ...t les instructions simples portées sur cette notice qui vous permettront d obtenir d excellents résultats dès la première utilisation Nous vous souhaitons une entière et pleine satisfaction quant à l utilisation de cet appareil moderne LE CONSTRUCTEUR Indice Istruzioni per l utente installazione 4 uso 4 8 manutenzione 10 Istruzioni per l installatore installazione 16 posizionamento 16 collegamento...

Page 3: ...connections Use Heating elements manual control Fig 1 2 2a 3 Rotate the knob concerned to the position correspondant to the needs of cooking taking into conside ration that to a higher number a higher heat supply corresponds see table use of heating elements Double circuit elements To switch on the second element turn the cooking control to maximum 11 then turn it again in the same direction as fa...

Page 4: ...ymbol the 0 zero figure of each heating element will start to flash and led A will switch on Immediately press the symbol corresponding to the selected heating element to adjust the cooking level from 1 to 9 Please bear in mind that higher the figure you select the greater will heating output see table How to use heating elements To decrease the cooking level press symbol 2 Switching off Press sym...

Page 5: ...ymbol In any case whenever two keys of the same heating element are accidentally touched at the same time or whenever liquids are split over the two keys at the same time the programmed selection will deactivate the heating elements will switch off and the writing INIT will appear which can be turned off by pressing symbol Double circuit elements To switch on the second element press the key until...

Page 6: ...es on the top or with void pots and pans At the end of cooking take again the knob to position 0 In the event of even a slight fracture on the cooking surface disconnect the electric power supply immediately Maintenance Fig 4 First of all remove stray food bits and grease drops from the cooking surface with the special scraper fig 4 Then clean the hot area as best as possible with SIDOL STAHLFIX o...

Page 7: ...regulador de energía touch control intensidade do calor 1 1 2 1 tenue weak faible schwach tenue zwak fraco 2 3 4 2 3 dolce gentle doux mild moderada zeer laag ligeire 3 5 6 4 lento slow lent mässig lenta laag lento 4 7 8 5 6 medio medium moyen mittel media medium médio 5 9 10 7 8 forte strong fort stark fuerte hoog forte 6 10 11 9 vivo bright vif sehr stark viva zeer hoog vivo no no non nein no ne...

Page 8: ...12 I GB F Fig 3 Abb 3 Afb 3 doppio circuito double circuit double circuit Doppelkreis doble circuito dubbele stroomkring duplo circuito GRILL GRILL OVALE OVAL ...

Page 9: ...left side Posterieur gauche Hinterlink Posterior izquierdo Linkse achterkant Posterior esquerdo 9 Anteriore sinistro Front left side Anterieur gauche Vorderlink Anterior izquierdo Linkse voorkant Anterior esquerdo 10 Anteriore destro Front right side Anterieur droit Vorderrecht Anterior derecho Rechtse voorkant Anterior direito doppio circuito double circuit double circuit Doppelkreis doble circui...

Page 10: ...ando en cuenta el factor de simultaneidad 0 75 In aanmerking van de Geleijktijdigheidsfactor 0 75 Tomando en consideração o factor de simultaneidade 0 75 H05RR F3x2 5 H05RR F4x1 5 H05RR F4x1 5 H05RR F5x1 5 Fig 4 Abb 4 Afb 4 Fig 6 Abb 6 Afb 6 Fig 5 Abb 5 Afb 5 H05RR F3x1 5 H05RR F4x0 75 CLASSE I TIPO Y CLASS I TYPE Y CLASSE I TYPE Y KLASSE I TYP Y CLASE I TIPOY KLAS I TYPE Y CLASSE I TIPOY ...

Page 11: ...ted from the electric system Positioning Fig 5 The appliance can be fitted into a work ing area as illustrated on the figure Apply the seal supplied over the whole perimeter of the working area Electrical connection Fig 6 Prior to carrying out the electrical connec tion please ensure that the plant characteris tics are such as to fol low what is indicated on the matrix plate placed at the bottom o...

Page 12: ...ch with minimum aperture between the 3 mm contacts dimensioned to bear the plate load and it must follow the standards in force the yellow green earth cable must not be interrupted by the switch The plug or omnipolar switch must be easily reached on the installed equipment The manufacturers decline any responsibility in the event of non compliance with what is described above and the accident prev...

Page 13: ... 11 monocircuit radiant Ø 210 2100 doseur d energie 0 11 misto alogeno radiante Ø 145 1200 regolatore d energia 0 11 mixed circuit radiant halogen Ø 145 1200 energy regulator 0 11 mixte halogène radiant Ø 145 1200 doseur d energie 0 11 misto alogeno radiante Ø 180 1800 regolatore d energia 0 11 mixed circuit radiant halogen Ø 180 1800 energy regulator 0 11 mixte halogène radiant Ø 180 1800 doseur ...

Page 14: ...ircuito radiante Ø 210 2100 regulador de energía 0 11 gemischter Halogen Strahlungskreis Ø 145 1200 Energieregler 0 11 Mixto halógeno radiante Ø 145 1200 regulador de energía 0 11 Gemengd halogeen uitstraaling Ø 145 1200 energieregelaar 0 11 Misto halogéneo radiante Ø 145 1200 regulador de energía 0 11 gemischter Halogen Strahlungskreis Ø 180 1800 Energieregler 0 11 Mixto halógeno radiante Ø 180 1...

Page 15: ...a ogni responsabilità per le possibili inesattezze contenute nel presente opuscolo imputabili ad errori di stampa o di trascrizione Si riserva il diritto di apportare ai propri prodotti quelle modifiche che ritiene necessarie o utili senza pregiudicare le caratteristiche essenziali The manufacturer declines all responsibility for possible inaccuracies contained in this pamphlet due to printing or ...

Reviews: