background image

 

User manual 

Symax (Mertik) ENG 

 

 

 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

40011927-1939 

 

Summary of Contents for Symax

Page 1: ...User manual Symax Mertik ENG 40011927 1939 ...

Page 2: ...al number This user manual is intended for the following gas fires MatriX 450 500 I II III MatriX 450 650 I II III MatriX 800 500 I II III MatriX 800 650 I II III MatriX 1050 500 I II III MatriX 1050 650 I II III Blokhus Respect Premium OC ...

Page 3: ...User manual Symax 2 1 1 1 2 1 3 1 4 1 5 1 6 2 0 ...

Page 4: ...ced around the fireplace As a fire is a source of heat hot air circulation is created As a result of natural air circulation moisture and not yet cured volatile components from paint building materials and carpeted floors are included in this air circulation These parts can settle as soot on cold surfaces The moment using the fire for the first time depends on various circumstances Consult your in...

Page 5: ...pair them again Remote control The battery indication in top right corner of the display screen indicates the status of the batteries fig 2 0 After replacing the batteries the settings of the Thermostatic and Program mode have been reset to the factory settings Section 6 2 and 6 3 Placing batteries in the remote control Slide the battery cover of the remote control fig 1 2 Place 2 AA 1 5 Volt Alka...

Page 6: ...wo key operation Standard is one key operation To set this immediately press the key for 10 seconds after placing the batteries and wait until 1 or 2 flashes Release the key when the desired number of flashes appear Basic functions Switching ON One key operation Press the key until two short beeps and blinking series of lines appears The fire automatically starts on high setting Fires equipped wit...

Page 7: ...onfirm press the key or wait Now the light effect is adjusted Extended functions Countdown timer Please note The countdown timer works in Manual and Thermostatic mode only Max countdown time is 9 hours and 50 minutes At the end of the countdown time the fire turns automatically off Set and turn on Press the key until appears in the display screen and the hour indication will blink Press the or key...

Page 8: ...he key until OFF appears and the temperature flashes Press the or key to set the switch off temperature To confirm press the key Set day ALL flashes Press the or key to set the right day or period To confirm press the key Set ON time Program 1 1 and ON appears in the display screen and the hour flashes Press the or key to set the switch on hour Press the key to confirm and the minutes flashes Pres...

Page 9: ...past the ON position fig 1 6 This causes a rattling sound Please note When step burner you can t switch between narrow and wide manually Fault codes remote control Fault code Duration time fault code on display Symptom Possible cause F04 4 sec No pilot flame within 30 sec Attention After 3 failed ignition attempts error code F06 appears No gas supply Air in burner pipe pilot flame No spark Reverse...

Page 10: ...User manual Symax 9 ...

Page 11: ...User manual Symax 10 ...

Page 12: ......

Reviews: