background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bath Lift User Manual 

 

     

Model # CH2100 

 
 
                                           
CH2100 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for CH2100

Page 1: ...1 Bath Lift User Manual Model CH2100 CH2100 ...

Page 2: ... 3 Components and parts 4 Pre Operation 4 Don ts 5 Charger 5 The charging process 5 Operation 6 Preparations before use 6 Before use 7 Set up and use 7 Emergency stop 8 Maintenance 8 Technical Data bath lift 9 Warranty 11 Troubleshooting 11 ...

Page 3: ... float in the water The drive motor and control electronics are comp3letely watertight so you can use it even when showering The sturdy frame dismantles enabling the seat to be raised or lowered from 8 cm to 48 cm 3 1 to 18 9 in height The lifting rod lifts and lowers the seat surface when the user pushes the up and down buttons The drive unit with integrated backrest can be folded down for remova...

Page 4: ... to ensure sure that the lift is suitable for them including user s weight size cognitive ability joint range of motion Please do not use the lift if there are any safety concerns and ensure there is a caregiver accompanying the user if there is any chance of them requiring assistance 5 Designed for use in standard bathtubs and check with a professional to ensure the product is suitable 6 Before e...

Page 5: ...s into the slider support area during use or maintenance 9 Don t modify equipment 10 Don t place objects in the scissors fork near such as toothbrush razor and so on 11 Don t allow the handset to be near high heat sources Charger 1 Please use dedicated charger 2 The best battery capacity will be reached after several charging cycles 3 When charging Please keep away water source heat source and so ...

Page 6: ...vent the bath chair from lifting up and lowering normally 3 Confirm the bathtub meets the relevant standard 4 Put the bath lift into the bathtub If difficult please get assistance 5 Please ensure the ground is dry and no obstacles to prevent some accidents while moving the bath lift 6 Please ensure there is enough space at the back of the bath chair in the bathtub 7 Ensure six suction feet are wel...

Page 7: ...st reclines to 45 by pressing the down button 8 When finished raise the bath lift up until the two side plates are supported on the edges of the bathtub then move your feet out of the tub and stand 9 Remove the bath lift from the tub if required 1 Before each use ensure that bath lift is operating normally and is safe for up down use 2 If the handset indicator lights please charge it first 3 Pleas...

Page 8: ...gents or disinfectants if needed use a damp cloth dipped in a small amount of cleaner on the handset and actuator Don t submerge in water Make sure that the battery is fully charged before use The voltage rating on the charging unit has to be compatible with the voltage of your power supply e g 220V 240V in Europe and 110V in Canada USA 3 Attention should be paid to lift scissors to avoid pinching...

Page 9: ... 360mm 13 8in 14 2in Backrest adjustment 5 max 45 Width of base plate 310mm 12 2in Length of base plate 612mm 24 1 Load capacity max 140kg 308 6 lb Total weight excl hand control 9 6kg 21 2 lb Total weight incl hand control 10 1kg 22 3 lb Weight of hand control incl battery 0 5kg 1 1 lb Weight of drive unit 3 6kg 7 9 lb Weight of seat unit 6 0kg 13 3 lb Duration of lifting lowering movement 105 kg...

Page 10: ...10 Initial position Highest height Folded size ...

Page 11: ...cturer will not accept responsibility for any damages or injury caused by misuse negligence or non observance of the instructions supplied Troubleshooting Error Possible cause Remedy Lift does not move Battery is flat Contacts on hand control are contaminated Hand control is not connected properly Charge battery Unplug hand control wipe contacts with a dry cloth and plug hand control in again Chec...

Page 12: ...ator to picture 2 by manually Picture1 Picture 2 4 If it is not possible to operate the bath lift despite observing all the above mentioned information please contact the specialist dealer who sold the device Imported and Distributed by HPU Medical Wholesale 34 Futurity Gate Unit 15 Vaughan Ontario L4K 1S6 Phone 416 739 1267 Toll Free 888 634 5808 Fax 416 739 7171 ...