background image

Operating Guide –airmate– Automatic tyre-filling machine
with a type approval for filling stations

GB

FN330-326GB  01/10

Armaturen- und Autogengeraetefabrik ewo
H. Holzapfel GmbH & Co. KG
Hessbruehlstrasse 45-47
70565 STUTTGART - GERMANY

www.ewo-stuttgart.com  –  [email protected]

– 1 –

Proper Use

The device is intended for the automatic filling of tyres and for checking the
pressure of such vehicle tyres. 
Two design variants with 5.5 and 10.0 bar max. fill pressure for passenger-
car and/or lorry tyres.
National permit by PTB available. Registration number: 18.08 / 08.06.This is
the prerequisite for calibration. The calibration can be performed either by the
manufacturer or by the customer and is valid for two years. For the setup
and operation at public filling stations and service stations in the Federal Re-
public of Germany, only calibrated devices may be used!

Warning symbol

This symbol should alert the user of important operating tips and 
steps involved in preventative maintenance – the compliance with

which is crucial to safe operation.

Caution!

Tyre-filling-machine with 10 bar max. Inflation pressure may only be used for
the filling of truck tires! These devices are marked with the words' for trucks.
The use for car tires only one device at 5.5 bar max. Inflation pressure used!
Excessive tire pressure can lead to the bursting of the tire.

The filling of bicycle tyres and other small tyres is prohibited due to
the risk of over-filling!

Electrical Connection

• The mains voltage may lie within the range of 90 to 240 V / 50-60 Hz
• The electrical connection must be grounded.
• The electrical connection must be safeguarded with a 10 A fuse (depen-

ding on heat output) which is easily accessible - and marked as a current 
interruption for your device.

• Never connect any other electrical consumers such as the cooling unit, the 

compressor or the vacuum cleaner to the same power source.

Let basically make electrical connections by qualified personnel.

Hose Fixture

The device can be equipped with a straight as well as a spiral hose. 
The straight hose can either be coiled around the device between the front
panel and the wall, or on a hose fixture. The spiral hose should be hung onto
the designated fixture. As an option, an automatic hose reel is available. This
accident can be prevented from tipping and to prevent damage to the hose
and the plug.

Installation and Setup

• The device is suitable for assembly inside or outside.
• The device must be attached with four screws to the wall or to a column.
• Connect the hoses for the pressure supply and for filling according to the 

affixed markings (G 

1

/

4

female thread).

• Guide electrical and pressurised-air lines along the wall to prevent acci-

dents.

Setup of the device in explosion-prone areas is prohibited!

Package Contents

The airmate standard model is supplied including the following:

• 3 m electrical cable with contact-safeguard plug
• Operation guide

Air-supply and fill hose both sold separately.

Technische Daten

Electrical  connection:

90  to  240 V / 50-60 Hz

Max. consumption:

16 W

Protection class:

IP54

Operating temperature:

-40 °C to +70 °C (built-in heater)

Fill pressure:

0,2 bis 5,5 / 10,0 bar (see nameplate!)

Max. compressor pressure:

16,0 bar

Pressure connector:

1

/

4

Medium:

Pressurised air, nitrogen (dry)

Weight:

approx. 3 kg

Dimensions (diameter x depth):

240 x 100 mm

Caution!

• Ensure that the pressure on the air-supply hose is no higher than 6.0 bar!

If necessary, install a pressure regulator!

• Notwithstanding the plastic filter element assembled in the hose connec-

tor, it is advisable to add a pressurised-air filter.

• To ensure safety, install a ball valve in front of the tyre-filling device. Prior 

to its connection, open this valve fir a short time to enable the rinsing of 
any dirt particles from the line.

• It is advisable to install a residual-current-operated device (RCD) with 30 

mA.

Reviews: