RETICULAR BACKLIGHTING SYSTEM | SCW

ITEM #: TX1-24-SCW SERIES (SINGLE COLOR WHITE)

CONTENTS

PROFILES 

(SEE SPEC SHEET FOR MORE DETAILS)

SAFETY INFORMATION

BEST PRACTICES

Each TRAX Single Color White package includes one TRAX Array (A) and 

two Wago connectors (B).

Read all instructions before beginning.

//  To reduce the risk of fire, electric shock, or injury to persons, pay close attention to this manual and stay within its guidelines when using this product. 

Save these instructions for future reference.

 READ AND FOLLOW THE PRODUCT HANDLING, INSTALLATION, & INTEGRATION ADVISORY ON PAGE 4.

// 

 WARNING: RISK OF ELECTRIC SHOCK. DISCONNECT POWER AT THE SOURCE BEFORE SNAPPING, CUTTING, OR ALTERING PRODUCT IN ANY WAY. DO 

NOT CONNECT TRAX TO AC CURRENT. USE ONLY WITH 24V DC INPUT POWER.

// Products should be installed in accordance with these instructions, local/regional electrical codes, and the current National Electric Code (NEC).

//  Use only with UL Listed or UL Recognized Class 2, Limited Power Source (LPS) or Low Voltage Limited Energy (LVLE) power supplies. Provide the appropriate 

number of 24V Class 2 circuits for your layout. Do not exceed the maximum load limit of any power supply per the manufacturer’s recommendations.

//  To retain Class 2 compliance per UL regulations, do not interconnect more than one full 24” x 96” (609.6mm x 2438.4mm) TRAX Array (86W). Use one 96W 

24V Class 2 LPS or LVLE power supply / channel per TRAX Array. Best practices include allowing headroom for power supply longevity. The TRAX system’s 

integrated wire clips have a 4A capacity. Do not exceed the load capacity of these in any configuration.

// This product is rated IP65 and can be used in wet locations, but not where water may accumulate.

//  Do not penetrate the TRAX LED bar with any type of mechanical fastener. Only use mechanical fasteners in the established, marked locations. See page 

3 - MOUNTING TRAX for more details.

// LEDs are bright. Do not look directly at lighted product.

//  Dry fit TRAX Array and power connections before permanently installing 

to a substrate. Always test operation before installing the translucent 

(forward-facing) material.

//  When not working with curved applications, the Rail Mounting Kit (sold 

separately: TX1-M-RMK) is strongly recommended. The Rail Mounting Kit 

will reduce installation time and labor while improving accuracy. 

//  Never slide heavy materials over product as this may cause damage to the 

lighting product or material.

// Avoid installing where subject to continuous flexing.

// For detailed, application specific installation guidance, please contact us.

PART

PRODUCT DESCRIPTION 

QTY

A

TRAX Array (24” x 96” / 609.6mm x 2438.4mm) with 64 LED bars each pre-
wired and pre-mounted to wire mounting clips

1

B

Wago same polarity, two port splicing connectors

2

ELECTRICAL

Input Voltage

24 Volt DC – Constant Voltage

Input Power

86W per TRAX Array, 1.34W per bar, 0.084W per LED

Connectivity

One TRAX Array to retain Class 2 compliance per UL regulations

Certification

IP65, cULus Listed (E495221), CE Compliant (EMC and LVD), and RoHS Certified

PHYSICAL

Cut Line Spacing

Snappable segments every 0.83” / 0.67” (21mm / 17mm)

Coverage

Up to 16ft

2

 (1.486m

2

) per Class 2 guidelines, 0,065ft

2

 (0.006m

2

) per bar

Operating Temp.

-22°F ~ +158° F (-30C ~ +70C)

POWER & CONTROLS

Compatible with full range (100% – 0%), flicker-free power and control components.

Please contact Evo-Lite for optimal solutions to fit your requirements.

B

TRAX ARRAY

WAGO CONNECTORS

24V

IP65

RoHS

 C O M P L I A N T

DIMMABLE

+

A

0.0625” 

(1.6mm)

0.313” 

(8mm)

Wire Clip

Wire Clip

LED Bar

24” (609.6mm)

HANDLING ADVISORY & PRE-INSTALL TESTING

Do not set anything on top of the product (i.e. tools, mugs, etc.). 

Avoid placing product on floor or anywhere it could be stepped 

on. The product may be damaged with improper handling.

Due to possible unforeseen issues with shipping and handling, 

we advise that all products be inspected at time of delivery and 

dry-fit  tested  for  proper  illumination  prior  to  mounting  and 

again before the forward-facing material is installed.

For troubleshooting guidance, please visit www.evo-lite.com

Summary of Contents for TRAX TX1-24-SCW Series

Page 1: ...an be used in wet locations but not where water may accumulate Do not penetrate the TRAX LED bar with any type of mechanical fastener Only use mechanical fasteners in the established marked locations See page 3 MOUNTING TRAX for more details LEDs are bright Do not look directly at lighted product Dry fit TRAX Array and power connections before permanently installing to a substrate Always test oper...

Page 2: ...lude allowing headroom for power supply longevity The TRAX system s integrated bar to wire connectors have a 4A capacity Do not exceed the load capacity of these connection blocks in any configuration The TRAX Array may be powered from any of the four wire leads Choose the best wire lead according to power supply location Do not exceed the 4A maximum load capacity in any configuration Use the incl...

Page 3: ...rd Bar Retention Clips sold separately TX1 BRC STD 10 to provide additional LED Bar support Step 1 Assemble The Rails Assemble the Rail Mounting Kit Rails A using the kit s included Rail To Rail Connectors B and End Mounting Clips D These pieces slide and click into place no tools required Rails may be cut to size Step 2 Prepare Mounting Location Mark the desired location for Rails A The correct d...

Page 4: ...can lose input power if snap lines are not followed Avoid cut edge contact with any conductive material s including other cut edges of TRAX Arrays See also Wet Location Use below SOLDERING DISCONNECT POWER AT THE SOURCE BEFORE ALTERING THE PRODUCT IN ANY WAY The unique power grid of TRAX prevents the need for soldering in most cases The LED bar s copper pads are engineered to handle 4A of load and...

Reviews: