background image

 

 

MCN40 

Pneumatic Joist Hanger Nailer 

 

 

 
 
 
 
 
 
 
 
 
 
 

OPERATIONS and MAINTENANCE MANUAL 

CE DECLARATION OF CONFORMITY 

 

 

 

 

 

   

  19’/3/19     

 

   

Everwin Pneumatic Corp. 

BEFORE OPERATING THIS TOOL, ALL OPERATORS SHOULD READ AND STUDY 

THIS MANUAL  TO UNDERSTAND AND FOLLOW THE SAFETY WARNINGS AND 

INSTRUCTIONS.  KEEP  THESE  INSTRUCTIONS  WITH  THE  TOOL  FOR  FUTURE 

REFERENCE. 

Summary of Contents for MCN40

Page 1: ... MANUAL CE DECLARATION OF CONFORMITY 19 3 19 Everwin Pneumatic Corp BEFORE OPERATING THIS TOOL ALL OPERATORS SHOULD READ AND STUDY THIS MANUAL TO UNDERSTAND AND FOLLOW THE SAFETY WARNINGS AND INSTRUCTIONS KEEP THESE INSTRUCTIONS WITH THE TOOL FOR FUTURE REFERENCE ...

Page 2: ...safety measures may be required because of your particular application of the tool Contact your EVERWIN representative or distributor with any questions concerning the tool and its use Everwin Pneumatic Corp Taichung City Taiwan 41353 INDEX 1 Year Limited Warranty 3 CE Declaration of Conformity 4 Safety Instructions 5 Specifications and Technical Data 6 Operating Pressure Setting Correct Pressure ...

Page 3: ...seals driver blades bumpers pistons and piston rings b Failure due to normal wear neglect abuse misuse misapplication accidents over pressure usage improper storage shipping damages improper maintenance operation not within the operation manual s specification etc are not covered by this warranty c Labor charges loss repairs from improper maintenance and or usage of non EVERWIN parts are not cover...

Page 4: ...idad ESPAGNOL EVERWIN PNEUMATIC CORP declaramos bajo nuestra sola responsabilidad que este producto esta en conformidad con las Directivas Europeas 2006 42 EC y con la normativa EN 792 13 Overensstemmelseserklæring CE Deklaration DANSK EVERWIN PNEUMATIC CORP erklærer herved at produktet er i overenstemmelse med nedenstående normer eller normative dokumenter 2006 42 EC i henhold til bestemmelserne ...

Page 5: ...sed the tool can remain charged with air after disconnecting and thus will be able to drive a fastener even after the air line is disconnected possibly causing injury Do not pull trigger or depress contact arm while connected to the air supply as the tool may cycle possibly causing injury Always disconnect air supply 1 Before making adjustments 2 When servicing the tool 3 When clearing a jam 4 Whe...

Page 6: ...SUMPTION Tool air consumption 3 8 cfm 1 8 liter sec of free air to operate at the rate of 100 nails per minute at 90 PSI 6 0 kg cm2 Take the actual rate at which the tool will be run to determine the amount of air required For instance if your fastener usage averages 50 nails per minute you need 50 of the tool air consumption in running at 100 nails per minute NOISE A weighted single event sound p...

Page 7: ...ailing without the possibility of driving a second unwanted fastener on recoil If trigger system is not operating as described do not use the tool and contact your nearest service center The operator must NOT hold the trigger pulled except during fastening operation as serious injury could result if the contact trip accidentally contacted someone or something causing the tool to cycle Keep hands a...

Page 8: ...n pneumatic tools A filter will help to get the best performance and minimum wear from the tool The filter must have adequate flow capacity for the specific installation The filter has to be kept clean to be effective in providing clean compressed air to the tool Consult the manufacturer s instructions on proper maintenance of your filter A dirty and or clogged filter will cause a pressure drop wh...

Page 9: ...cles and face shields alone do not provide adequate protection TO PREVENT ACCIDENTAL INJURIES Never place a hand or any other part of the body in nail discharge area of tool while the air supply is connected Never point the tool at anyone else Never engage in horseplay Never pull the trigger unless nose is directed at the work Always handle the tool with care Do not pull the trigger or depress the...

Page 10: ......

Page 11: ......

Page 12: ...mechanism Push and rotate the Trigger Lock Dial to the trigger free position before driving nails DIRECTIONAL EXHAUST COVER ALWAYS disconnect air supply before rotating the exhaust cover by hand Direction of the exhaust air is changed by rotating exhaust cover by hand ...

Page 13: ...ly for the purpose for which it was designed like pallet crating sheathing decking applications Never use this tool in a manner that could cause a fastener to be directed toward the user or others in the work area Do not use the tool as a hammer Always carry the tool by the handle Never carry the tool by the air hose Do not carry this tool with the trigger depressed when not in use Do not alter or...

Page 14: ...uced driving power Before evaluating tool problems for these symptoms trace the air supply from the tool to the supply source for restrictive connectors swivel fittings low points containing water and anything else that would prevent full volume flow of air to the tool DRIVER MAINTENANCE INSTRUCTIONS Worn driver causing poor quality or loss of power Wear or a chip on the driving tip will affect th...

Reviews: