8x J2K Encoders and SMPTE ST2110 Encapsulation paths driven by 

 2x UHD or 8x 3G SDI Inputs, 6x 10GbE SFP Cages 

 

 

User Manual 

 

 

 

 
 
 
 
 
 
 
 
© Copyright 2018 
 

EVERTZ MICROSYSTEMS LTD. 

5292 John Lucas Drive 
Burlington, Ontario  
Canada L7L 5Z9 
 
Phone: 

+1 905-335-3700 

Sales: 

[email protected] 

Fax: +1 905-335-3573 

Tech Support:  [email protected]  

Fax: +1 905-335-7571 

Web Page: 

http://www.evertz.com

     Twitter:      

@EvertzTV

 

 
Version 1.0, December 2018 
 

The material contained in this manual consists of information that is the property of Evertz Microsystems and is intended solely for the use of 
purchasers of the 570REM-TX8-10GE. Evertz Microsystems expressly prohibits the use of this manual for any purpose other than the operation of 
the 570REM-TX8-10GE. 
 
All rights reserved.  No part of this publication may be reproduced without the express written permission of Evertz Microsystems Ltd.  Copies of 
this manual can be ordered from your Evertz dealer or from Evertz Microsystems. 

 

 

Summary of Contents for 570REM-TX8-10GE

Page 1: ...com Twitter EvertzTV Version 1 0 December 2018 The material contained in this manual consists of information that is the property of Evertz Microsystems and is intended solely for the use of purchasers of the 570REM TX8 10GE Evertz Microsystems expressly prohibits the use of this manual for any purpose other than the operation of the 570REM TX8 10GE All rights reserved No part of this publication ...

Page 2: ...This page left intentionally blank ...

Page 3: ...rd grounding prong The wide blade or the third prong is provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manufa...

Page 4: ...ly to cause harmful interference in which case the user will be required to correct the interference at his own expense INFORMATION TO USERS IN THE U S A NOTE FCC CLASS A DIGITAL DEVICE OR PERIPHERAL This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against ...

Page 5: ...ffered by Evertz in relation to this product is the Evertz standard limited warranty stated in the sales contract or order confirmation form Although every attempt has been made to accurately describe the features installation and operation of this product in this manual no warranty is granted nor liability assumed in relation to any errors or omissions unless specifically undertaken in the Evertz...

Page 6: ...570REM TX8 10GE User Manual Revision 1 0 This page left intentionally blank ...

Page 7: ...R OF SLOTS 8 3 8 ENCLOSURES 8 4 WEB INTERFACE 9 4 1 SYSTEM 11 4 1 1 Control Port Configuration 11 4 1 2 Data Port Configuration 12 4 1 3 Data Port Monitor 12 4 1 4 SFP Monitor 13 4 1 5 Temperature Monitor 13 4 1 6 Configuration Management 14 4 1 7 Time Management 14 4 1 8 Card Control 14 4 1 9 Genlock 14 4 2 PRODUCT FEATURES 15 4 2 1 License Control 15 4 2 2 Product Features Supported 15 4 3 SDI I...

Page 8: ...URES Figure 1 1 570REM TX8 10GE Block Diagram 1 Figure 2 1 570REM Rear Plate 3 Figure 2 2 570FC Proxy Address 4 Figure 4 1 WebEASY Login Menu 9 Figure 4 2 WebEASY 570REM TX8 10GE Main Menu 10 Figure 4 3 WebEASY System Part 1 11 Figure 4 4 WebEASY System Part 2 13 Figure 4 5 WebEASY Product Features 15 Figure 4 6 WebEASY SDI Input Control 16 Figure 4 7 WebEASY IP Output Control 17 Figure 4 8 WebEAS...

Page 9: ...EM TX8 10GE can be managed via integrated HTTP web interface as well as SNMP management via Frame controller Features Benefits 8x 3G HD SD or 2x UHD JPEG2000 and 2x Mosaic JPEG2000 encodes 8x 3G HD SD SDI loop outputs Standards supported 3840x2160p 59 94 50 Quad Division or 2SI 1080p 59 94 50 Level A 1080i 59 94 50 720p 59 94 50 625i 50 and 525i 59 94 Support VSF TR 01 v2 Mezzanine Encode Processi...

Page 10: ...570REM TX8 10GE User manual Page 2 Revision 1 0 This page left intentionally blank ...

Page 11: ... with a companion rear plate and occupy two slots in 570FR 2 1 REAR AND FRONT PLATE The rear plate of 570REM TX8 10GE is equipped with 20 Mini Din connectors Figure 2 1 570REM Rear Plate The front plate of 570REM TX8 10GE has 12 available SFP slots These SFP slots can be populated with SFP10G TR13 A ...

Page 12: ...s of the fiber are dependent on the shape of the optical core and therefore care must be taken to prevent fiber damage due to heavy objects or abrupt fiber bending Evertz recommends that the user maintains a minimum bending radius of 5 cm to avoid fiber bending loss that will decrease the maximum attainable distance of the fiber cable The Evertz fiber optic modules come with cable lockout devices ...

Page 13: ...ocate on the rear of the rack the two slots and remove the blanking panels Insert the rear panel into the back of the chassis and secure using the four screws provided Now insert the 570REM TX8 10GE card into the corresponding front slots ensuring the card lines up with the slot runners on the bottom and the top of the chassis Push the card firmly into the slot ensuring that when it mates with the...

Page 14: ...570REM TX8 10GE User manual Page 6 Revision 1 0 This page left intentionally blank ...

Page 15: ... 5 Gb s and 350 270Mb s Return Loss 15dB up to 5 GHz 10dB up to 3 GHz 3 3 SERIAL VIDEO OUTPUT Number of Outputs 8 Connector DIN 3 4 IP INPUT Ethernet Interface 6 x 10GE SFP SFP Encapsulation MPEG 2 TS over IP Uncompressed SMPTE ST 2110 Ethernet IP Signaling Multicast 3 5 EMBEDDING OF HANC VANC 4x Groups Audio Pass through per encoder All type of VANC data pass through 3 6 ELECTRICAL Power 90W Volt...

Page 16: ... 2 3 8 ENCLOSURES 570FR 3RU Chassis 1RU Chassis Ordering Information 570REM TX8 10GE 8x J2K Encoders and SMPTE ST 2110 Encapsulation Paths driven by 2x UHD or 8x 3G SDI Inputs 6x 10GbE SFP Cages SFP Modules SFP10G TR13 A 10GbE Optical SFP SFP10G TR85 A SFP Optical Transceiver 10Gbs 850nm MMF ...

Page 17: ... the required network addresses it can be completely configured using the web interface For doing this simply type the IP address of the control port of the 570REM TX8 10GE module in the web browser Note Computer must be on the same Subnet in order to have communication with the module Figure 4 1 WebEASY Login Menu Login and password is root and evertz respectively On the web interface there are s...

Page 18: ...570REM TX8 10GE User manual Page 10 Revision 1 0 Figure 4 2 WebEASY 570REM TX8 10GE Main Menu ...

Page 19: ...ias This parameter indicates the card alias string 4 1 1 Control Port Configuration IP Address This parameter allows the user to set IP address for control port Netmask This parameter allows the user to set Netmask for control port Gateway This parameter allows the user to set Gateway for control port ...

Page 20: ...cates bitrate received on this output Ethernet port unit is kbps Transmitted Data Ethernet Total Bitrate This field indicates bitrate transmitted on this output Ethernet port unit is kbps Rx Frame Count This parameter indicates received Rx frames on this Ethernet port Rx CRC Error Frame Count This field indicates received Rx frames with CRC errors on this Ethernet port Rx Undersized Frame Count Th...

Page 21: ... This parameter indicates the part number of SFP SFP Type This field indicates the type of SFP SFP Rx Power Level This field indicates the received power level of SFP SFP Tx Power Level This field indicates the transmitted power level of SFP 4 1 5 Temperature Monitor Temperature This field shows the FPGA temperature ...

Page 22: ...ine timezone offset Day Light Savings This dropdown allows the user to select whether to apply Day Light savings or not External NTP Server This control allows the user to define an external NTP server 4 1 8 Card Control Load Factory Config This control is used to load factory configuration Reboot Card This button allows the user to perform a soft reboot on the card 4 1 9 Genlock Genlock Reference...

Page 23: ...s parameter displays the card MAC address Export Product License File The download button allows the user to download and export a product license file Import Product License File By clicking Choose File button a product license file can be uploaded to the module 4 2 2 Product Features Supported Product feature Name This parameter indicates the product features supported on this card Product featu...

Page 24: ...s Input Alias This control allows the user to set an alias name for input Video Standard Detected This parameter displays the detected video standard of SDI input It s not available if input is ASI SDI Loss Count This parameter indicates the number of SDI loss Clear Count This button allows the user to clear all input status ...

Page 25: ... disable output IP Output Source IP Address This parameter allows the user to define source IP address IP Output Source UDP Port This parameter allows the user to define source UDP port number IP Output Destination IP Address This parameter allows the user to define destination IP address IP Output Destination UDP Port This parameter allows the user to define destination UDP port IP Output Time To...

Page 26: ...ds on the number of J2K enabled User configurable latency settings are Standard Medium low and Ultra low Color Specification This control allows the user to set the color specification of the encoding process it should be displayed if any product feature support J2K encoder is enabled and the number of index to be displayed depends on the number of J2K encoder enabled Total TS Bit Rate This parame...

Page 27: ... on the number of J2k encoder enabled Transport Stream ID This parameter allows the user to set the transport stream ID of the stream It should be displayed if any product feature which support J2k encoder is enabled The number of index to be displayed depends on the number of J2k encoder enabled Program Name This parameter allows the user to set the title of the program It should be displayed if ...

Page 28: ...et the jitter tolerance for the master PCR time reference 4 5 6 Encoder Reference PCR Control For encoder 1 10 PCR Synchronization Source This dropdown allows the user to select a source from which to synchronize PCR Jam Counter This parameter is a counter for the amount of times that the threshold has been exceeded forcing a jam Force Jam This button allows the user to force a jam 4 5 7 Encoder C...

Page 29: ... to select the main data port Backup Data Port Select This dropdown allows the user to select the backup data port Fail Over Mode Selection This dropdown allows the user to select the failover mode for the received master PCR stream Fail Over Status This parameter displays the current status of the master PCR fail over PTP or Master PCR Presence This parameter indicates whether a valid Master PCR ...

Page 30: ...allows the user to set the UDP port number from which to obtain the Master PCR time reference PCR PID This parameter allows the user to set the expected PCR PID PCR Presence This field indicates whether PCR presence is detected on this data port or not Input IGMPv3 Mode This field allows the user to select the Master PCR IGMP V3 mode IGMPv3 SSM Src 1 6 IP Address This parameter allows the user to ...

Page 31: ...This field allows the user to enable disable sending audio groups to separate IP and port destinations 4 7 2 Breakaway Audio Group For Audio Group 1 4 Destination IP Address This parameter allows the user to set the destination IP address for breakaway audio group Destination UDP Port This parameter allows the user to set the destination UDP port address for breakaway audio group ...

Page 32: ...wn allows the user to set the output video standard 4 8 2 Mosaic Audio Bar Overly Audio Bar Overly This parameter allows the user to enable disable the Audio Bar Overlay 4 9 SYSTEM NOTIFY Figure 4 13 WebEASY System Notify 4 9 1 System Monitoring Control Temperature Warning Threshold This parameter allows the user to set the threshold for the temperature overheat ...

Page 33: ...eived Bandwidth Threshold This parameter allows the user to set the received bandwidth threshold 4 9 2 System Notify System Traps This dropdown is used to turn traps on and off System Faults This control checks whether a fault is currently present or not ...

Page 34: ...labeled Upgrade The Upgrade tab is used to check current firmware version and upload the latest firmware Figure 5 1 Figure 5 1 WebEASY Upgrade Button on Top Menu Bar Selecting the Upgrade tab will take the user to Figure 5 2 where the current firmware version is shown The user needs to download the firmware image file if the firmware version is outdated Figure 5 2 WebEASY Firmware Upgrade Menu Cli...

Page 35: ...ision 1 0 Page 27 Figure 5 3 WebEASY Firmware Upgrade Menu Selecting Firmware File Once selected click open to advance to next step Click upgrade and watch progress bar for status Once completed the device will automatically restart ...

Page 36: ...570REM TX8 10GE User manual Page 28 Revision 1 0 The End ...