background image

WARNING

•  These instructions must be read, understood, and followed: improper use or failure to wear the respirator during all times of exposure 

may result in severe illness, permanent disability or death. 

•  Always be sure both mask and filter selection is: appropriate for the application; worn at all times during exposure; filters are replaced 

when necessary. 

•  Refer to information supplied to check suitability or contact Euromarc 0800 278 600.
•  Do not use in environments at less than 19.5% oxygen.
•  Only use with Euromarc Craftsman filters listed in the table below and only in the stated applications. 
•  The wearer must be trained in the use of all equipment and in respect of relevant workplace health and safety regulations. 
•  Beards and facial hair will inhibit the effective sealing of the mask against the user’s skin. Use an alternative mask if a complete  

and effective seal is not achievable. 

•  Do not use in flammable environments.
•  Do not use if type, toxicity or concentration of contaminants is unknown. Do not enter hazardous area. 
•  Leave work area immediately, check integrity of respirator and replace any parts if: a) damage has occurred or is apparent.  

b) dizziness, illness or irritation occurs. c) breathing resistance increases. Dispose of all used filters. 

•  Never modify or alter this product, doing so could jeopardize your safety. 
•  While materials in this mask do not commonly cause allergic reactions, if you notice any reaction or irritation cease use  

and seek medical advice. 

•  P3 rated protection can only be achieved when using a full-face mask, irrespective of filter choice. 

PREPARATION FOR USE

Check that the mask is complete, undamaged and assembled correctly.  
Damaged or faulty respirators must be replaced - contact Euromarc 0800 278 600.

INSPECTION 

The following points must be checked before use:
1.  The material should be soft and pliable to conform to the face. Check the face-piece, valves and diaphragm for  

any cracks or tears and ensure the shape of the mask is not distorted.

2.  Make sure all seals are correctly positioned. Remove the front plastic piece to check the exhalation diaphragm.
3.  Inspect head-straps, clips and harness to ensure an effective seal. 
4.  Ensure mask is clean. Dust and dirt in the valves or bayonet fittings can impair effective protection.

This product meets the requirements of AS/NZS 1716:2012 and should be used in 
combination with a pair of approved Euromarc Craftsman filters to form a filtering 
apparatus for respiratory protection. 

USER INSTRUCTIONS 

Please read these instructions before using the Euromarc Craftsman 710 series 
masks and filters. 

HALF FACE  

RESPIRATOR

ART.

Pcs.

SIZES

C710-7

S

1

C710-8

M

1

C710-9

L

1

Euromarc 710 Series Filter

710

AS/NZ 1716 : 2012 Lic 40344

SAI Global

Reviews: