background image

 

 

 
 
 
 
 
 
 
 

 

 

 
 

PL6 / PL7  

(115 V) 

 

SERVICE MANUAL 

 

 

 
 
 
 
 
 
 
 
 

 
 
 
 
 

 
 
 

Eurochef srl  Viale delle Nazioni n. 101 

– 41122 Modena (Italy) 

Tel. +39 059-315146- Fax +39 059-3160787 - 

www.eurochef.it

 [email protected] 

Summary of Contents for Pasta Chef PL6

Page 1: ...1 PL6 PL7 115 V SERVICE MANUAL Eurochef srl Viale delle Nazioni n 101 41122 Modena Italy Tel 39 059 315146 Fax 39 059 3160787 www eurochef it eurochef eurochef it ...

Page 2: ...s Eurochef declines all responsibility where improper use of the machine causes personal injury accidents or damages to property 2 SPECIFICATION AND TECHNICAL DATA Baskets working separately with different time scales Basket control with 4 pre set times for each basket PL6 with sauce heater PL7 without sauce heater Reprogramming times Keyboard operated Basin capacity 10 litres approx Water control...

Page 3: ...when the temperature of the water is higher than 90 C Electrical connection Ensure that the plant is well earthed according to IEC regulations and check that the current corresponds with that stated on the registration plate on the machine Finally check that the plant to which the machine is connected has the power shown on the registration plate There must be an automatic fused or thermally prote...

Page 4: ... 16 max basket motion time 25 seconds 17 time for level alarm switch on 10 seconds 18 max time for refill 20 minutes 19 motion time to offload left basket 30 second tenths 20 right basket rising time 46 second tenths 21 right basket descending time 35 second tenths 22 motion time to off load right basket 33 second tenths 23 interval motion baskets 20 seconds 24 part load heating 01 minute 25 off 0...

Page 5: ... the element becomes hot Pressing 2 the display shows U 2 which is the output of the air blower U 3 is the left hand motor when it lifts the basket and U 4 the same motor when it lowers the basket In order to test also the microswitch of the motor it is better to remove the baskets before making the test In this way the motor shaft can turn freely and the lever of the microswitch can enter and exi...

Page 6: ...malfunctioning of the probe A03 Non control of the left motor The signal indicates that the motor does not stop at the preset time which might be because 1 the cam on the motor itself has shifted or 2 the relevant microswitch is broken or 3 a total motion time of the basket was preset which is higher than the limit normally 25 seconds foreseen for programme 16 A04 Non control of the right motor As...

Page 7: ...7 PICTURE A MAIN SWITCH HEATING ELEMENT CONNECTOR KEYBOARD TEMPERATURE LEVEL WATER PROBE PROBE JUNCTION ...

Page 8: ...8 PICTURE B HEATING RELAY TRANSFORMER BLOWER ELECTRONIC BOARD SAUCES MICROSWITCH MOTOR OF THE THERMOSTAT LEFT BASKET ...

Page 9: ...9 PICTURE C SAUCE WARMER WATER TANK MICROSWITCH MOTOR OF THE RIGHT BASKET SOLENOID VALVE ...

Page 10: ...10 ...