background image

 

1

 

 

 

 
 
 
 
 
 
 
 
 
 

 

 
 

INSTALLATION GUIDE 

 

 

  

 
 
   

 

 

FOR EXTERNAL INSTALLATION ONLY

 

Eternity 

GAS WATER HEATERS 

 

MODELS 16-18-20-24-26

Summary of Contents for 16

Page 1: ...1 INSTALLATION GUIDE FOR EXTERNAL INSTALLATION ONLY Eternity GAS WATER HEATERS MODELS 16 18 20 24 26 ...

Page 2: ...G DIAGRAM OPERATING SAFETY WATER FLOW AND WATER TENPERATURE WARANTY CONDITIONS 17 18 18 18 19 20 20 21 21 22 24 25 26 28 28 IMPORTANT This User Guide has been prepared for Installers and Servicers of the equipment Please keep it in a safe place for future reference FOR THE INSTALLER The installation must be done in accordance with the information supplied in this User Guide All other relevant Nati...

Page 3: ...5 max Inlet Pressure kPa LPG 2 75 min max 2 75 min max 2 75 min max 2 75 min max 2 75 min max Water Supply Pressure kPa 150 min 1200 max 150 min 1200 max 150 min 1200 max 150 min 1200 max 150 min 1200 max Height mm 542 542 542 542 542 Depth mm 170 170 170 215 215 Width mm 350 350 350 350 350 Weight kg 15 7 15 7 15 7 17 2 17 2 Gas Connection mm 20 BSP 20 BSP 20 BSP 20 BSP 20 BSP Water Connections 1...

Page 4: ...e water heater is simple Burner Heat exchanger Exhaust Flow sensor Thermistor Computer board AC240V Gas valve Fan Cold water inlet Gas Hot water outlet 1 A hot water tap is turned on 2 Water enters the heater 3 The water flow sensor detects the water flow 4 The computer automatically ignites the burner 5 Water circulates through the heat exchanger and then gets hot 6 The computer will modulate the...

Page 5: ...LD 86 GAS 114 HOT 124 POWER 34 ACCESSORIES Check that the installation manual and screws are included with the unit Screws 4 Manual DIMENSIONS AND CONNECTION POINTS GAS COLD HOT GAS HOT COLD 1 9 3 7 330 350 4 9 0 124 133 335 4 4 5 G A S 5 2 0 4 1 H O T 4 9 C O L D 198 60 94 215 182 5 4 2 15 7 84 34 POWER 2 5 P O W E R Model24 Model26 Model16 Model18 Model20 ...

Page 6: ...O NOT install the water heater indoors WARNING Water temperatures above 50 can cause severe burns or death from scalding Children the disabled and the elderly are at a high risk of being injured Feel the water temperature before bathing or showering Do not leave children disabled persons or the elderly unsupervised The Australian Standards AS 3498 gives full details of the requirements for supply ...

Page 7: ... AS3500 4 before cutting or uncoupling existing metallic pipework It should be as close as practical to the hot water outlets to minimise heat loss and cost The water heater does not require a fireproof back plate if installed on timber wall Rating Label Position on Cabinet Gas Type Label Position on Cabinet CAUTION This equipment is not suitable for pool or spa heating Water hardness may affect t...

Page 8: ...water heating apparatus only and the final fitness of water delivered is dependent upon the quality of water supplied to this system Although the water heater is designed to operate with minimal sound you should not install the unit on a wall adjacent to a bedroom or a room that is intended for quiet study or meditation etc Locate your heater close to a drain where leakage will not do damage to su...

Page 9: ...RANCES FOR OUTDOOR HEATER LOCATIONS AS5601 Exemption from prescribe statutory requirements referred to in Figure 1 has been granted to allow multiple series of the Water Heaters to be positioned side by side ...

Page 10: ...ect the unit to the gas line Always purge the gas line of any debris before connecting to the water heater Install a manual gas shut off valve between the water heater and the gas supply line The regulator is preset at the factory It is computer controlled and is not to be adjusted by any person other than a qualified Service Provider When the gas connections are completed it is necessary to perfo...

Page 11: ... the water heater shown in the diagram to the right 4 Connect the manometer to the pressure port 5 Re open the manual gas valve Check to see that there are no gas leaks 6 Open some of the fixtures that use the highest flow rate to turn on the water heater 7 Check the inlet gas pressure When the water heater is on a maximum burn the inlet gas pressure within must be within the appropriate range Ple...

Page 12: ...er flush the water line to remove all debris and after installation is complete purge the air from the line Failure to do so may cause damage to the heater There is a wire mesh filter to discourage debris from entering your heater Clean filter after initial installation to ensure no debris from the pipe work has clogged it NOTE This filter must be cleaned as part of regular maintenance HOT WATER O...

Page 13: ... water heater for easy access 4 Install so that the electrical power can be switched off if necessary 5 If the cord supplied with this appliance must be replaced it must be replaced with appliance wiring material supplied by the Manufacturer WARNING When servicing or replacing parts within the water heater label all wires prior to disconnection to facilitate an easy and error free reconnection Wir...

Page 14: ...utput temperature from the water heater to be adjusted within the range of 37ºC to 55ºC The temperature options are 37ºC 38ºC 39ºC 40ºC 41ºC 42ºC 43ºC 44ºC 45ºC 46ºC 47ºC 50ºC 55ºC When BURNER ON lamp is lit the set temperature can not be adjusted to 55ºC If you desire to set it to 55ºC you should close the hot water tap MODEL FC100W AU3 SHOWER CONTROLLER AND SC100 AU3 ENSUITE CONTROLLER FC100W AU...

Page 15: ...ttach the remote control to brittle you should use the anchor plug Connector base WARNING DO NOT locate the remote controls where they may come into contact with water DO NOT position the remote controls in the vicinity of chemicals DO NOT position the remote controls over a cooker grill or toaster DO NOT position the remote controls where materials may spill onto them PLEASE NOTE IF THE CONTROLS ...

Page 16: ... to remote terminals directly There is no polarity in the terminations DO NOT jump or short circuit wires Computer will be damaged 5 Replace the plastic cover and the front cover And connect the power plug REMOTE CONTROL CABLE CONNECTIONS TYPICAL CABLE LAYOUT 1 2 3 4 5 6 7 8 PLASTIC COVER REMOTE CONTROL CABLE REMOTE CONTROL TERMINAL REMOVE THE PLASTIC COVER AND CONNECT TO TERMINALS DIRECTLY BEHIND...

Page 17: ...et Do not use this water heater if any part has been submersed under water Immediately call a qualified service technician to inspect the water heater and to replace any damaged parts CAUTION IF YOU SMELL GAS Do not try to start the water heater Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier ...

Page 18: ...ure on the remote controller 2 Set temperature which you want When adjust the set temperature with MC100 AU3 it allows the output temperature from the water heater to be adjust within the range of 37ºC to 55ºC please refer to P 14 3 Open a hot water tap and ensure the BURNER ON lamp is lit Mix cold water with the hot if you need 4 Close the hot water tap and ensure the BURNER ON lamp is OFF MC100 ...

Page 19: ...ority setting is transferred to FC100W AU3 or SC100 AU3 if the previous temperature setting which stored in FC100W AU3 or SC100 AU3 was 43ºC and above it become to 42ºC 3 Open a hot water tap and ensure the BURNER ON lamp is lit Mix cold water with the hot if you need 4 Close the hot water tap and ensure the BURNER ON lamp is OFF WARNING Water temperatures above 50 can cause severe burns or death ...

Page 20: ...l hot water taps in the house Bathroom kitchen laundry room etc When the water flow has ceased close all hot water taps 5 Have a bucket or pan to catch the water from the unit s drain plugs Unscrew the drain plugs to drain all the water out of the unit 6 Wait a few minutes to ensure all water has completely drained from unit 7 Securely screw the drain plugs back into place Hand tighten only When i...

Page 21: ...ual gas shut off valve 2 Turn off the power supply to the water heater 3 Close the manual water shut off valve 4 Open all hot water taps in the house Bathroom kitchen laundry room etc When the residual water flow has ceased close all hot water taps 5 Have a bucket or pan to catch the water from the unit s drain plugs Unscrew the drain plugs to drain all the water out of the unit 6 Wait a few minut...

Page 22: ...he hot water is not available when a fixture is opened Make sure the unit has 240V 50Hz power supply If you are using the remote controller is the power button turned on p 18 19 Is the gas supply valve fully open p 17 Is the water supply valve fully open p 17 Is the filter on cold water inlet clean p 21 Is the hot water fixture sufficiently open to draw at least 3 0l min through the water heater p...

Page 23: ...stopped the fan motor keeps running for 15 75 seconds in order to re ignite quickly as well as push all exhaust gas out of the flue REMOTE CONTROLLER OPTIONAL PROBLEM POSSIBLE SOLUTIONS Remote controller does not display anything when the power button is turned on Press the ON OFF button If the lamp does not light Make sure the unit has power supply Make sure the connection to the unit is correct ...

Page 24: ...des On the PCB or Temperature Remote Controllers The LED on the PCB Error Code on Remote Controller Symptom Burning LED 1 Time Blink 03 Incorrect Dipswitch Setting Gas 70 Proportional valve computer Burning LED 2 Times Blink 31 Output Thermistor 32 Inlet Thermistor 39 Air fuel Ratio Rod Failure Burning LED 3 Times Blink 11 Ignition Failure 12 Flame Loss 51 Abnormal Main Gas valve or Gas solenoid V...

Page 25: ...BK W Increase button Decrease button MAX button MIN button Dipswitches Ground BK W Fuse 5A PCB Mo del 26 Mo del 24 Heater Thermostat Heater W W BK BK B K W W W 240 VAC Ground BR BL Y G BK W BK W BK W BK W MA IN PCB GS 00W AU W WHITE R RED BK BLACK P PURPLE LB LIGHT BLUE BL BLUE G GREEN Y YELLOW O ORANGE BR BROWN PK PINK 45 40 55 50 error 60 error DEFAULT Temperature Settings OFF ON 5 6 7 8 5 6 7 8...

Page 26: ... technician Force or attempted repair may result in a fire of explosion D Do not use this water heater if any part has been under water Immediately call a qualified service technician to inspect the water heater and to replace any damaged parts OPERATING INSTRUCTIONS 1 STOP Read the safety information above or in the Owners Manual 2 Turn off all electric power to the water heater 3 Do not attempt ...

Page 27: ...ducts will be stored Read and follow water heater warnings and instructions If owner s manual is missing contact the retailer or manufacturer WARNING The outlet hot water temperature of the water heater is factory set at 70 C Use this heater at your own risk The set outlet water temperature can cause severe burns instantly or death from scalds Test the water before bathing or showering Do not leav...

Page 28: ...t Put Hot Water l min 5 10 15 20 5 20 1 19 5 19 0 18 4 17 9 17 4 17 0 16 5 16 1 15 7 15 3 14 3 12 9 11 7 9 2 10 23 9 23 0 22 2 21 5 20 8 20 1 19 5 19 0 18 4 17 9 17 4 16 1 14 3 12 9 9 9 15 26 0 26 0 26 0 25 8 24 8 23 9 23 0 22 2 21 5 20 8 20 1 18 4 16 1 14 3 10 7 20 26 0 26 0 26 0 26 0 26 0 26 0 26 0 26 0 25 8 24 8 23 9 21 5 18 4 16 1 11 7 37 38 39 40 41 42 43 44 45 46 47 50 55 60 75 Model26 Out P...

Reviews: