background image

E T C

®

  I n s t a l l a t i o n   G u i d e

Unison Paradigm Wall Mount Touchscreen

.

c

n

,

sl

o

rt

n

o

C

 

e

rt

a

e

h

T

 

ci

n

o

rt

c

el

E

4

 f

o

 

1

 

e

g

a

P

n

e

e

r

c

s

h

c

u

o

T

 t

n

u

o

M

 l

la

W

 

m

gi

d

a

r

a

P

 

n

o

si

n

U

Corporate Headquarters   3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA   Tel +608 831 4116   Fax +608 836 1736

London, UK   Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK   Tel +44 (0)20 8896 1000   Fax +44 (0)20 8896 2000

Rome, IT   Via Ennio Quirino Visconti, 11, 00193 Rome, Italy   Tel +39 (06) 32 111 683   Fax +44 (0)20 8896 2000

Holzkirchen, DE   Ohmstrasse 3, 83607 Holzkirchen, Germany   Tel +49 (80 24) 47 00-0   Fax +49 (80 24) 47 00-3 00

Hong Kong   Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong   Tel +852 2799 1220   Fax +852 2799 9325

Service: (Americas)

 [email protected]

   (UK)

 [email protected]

   (DE)

 [email protected]

   (Asia)

 [email protected]

Web:

 www.etcconnect.com

   Copyright © 2008 ETC. All Rights Reserved.   Product information and specifications subject to change.

7184M2100   Rev A   Released 11/2008

  

ETC intends this document to be provided in its entirety.

Overview

The Unison

®

 Paradigm™ Wall Mount Touchscreen uses a high-resolution, 7”-wide screen, color 

liquid-crystal display (LCD) that is bright and easy to read, with controllable back lights. The 

Touchscreen is installed in a flush mount backbox or a surface backbox, which is shipped separately. 

The Touchscreen is also available in rack mount and locking cover configurations. The Touchscreen is 

powered by either LinkPower and Auxiliary power or PoE (Power over Ethernet 802.3af).

Echelon

®

 LinkPower

®

 (LinkConnect) control network utilizing Belden 8471 (or approved equal) 

and 24 Vdc Auxiliary power (two 16 AWG 1.5mm

2

) wires.

PoE (Power Over Ethernet 802.3af) utilizing Category 5 cable (or approved equal).

All control wiring should be installed and terminated by a qualified installer and should follow standard 

wiring installation practices. Leave approximately 10 inches (254mm) of wiring in the backbox for 

connection and to allow slack for future service needs. For more information about terminating Cat5 

cable, refer to the 

ETC Ethernet Cat5 Termination Kit Setup Guide

.

Installing the Backbox

Installation should follow local codes and standard practices. Ensure that the backbox is clean and free 

of obstructions. Ensure that all wiring is installed correctly. The touchscreen is supplied with an 

installation kit which includes hardware and electrical supplies for most applications. 

Flush Mount Backbox

The hole in the wall should be cut carefully so there are no gaps around the box. The installation kit 

includes two lengths of screws for depth adjustment and screws for securing the collar.

Surface Mount Backbox

Do not use the depth adjustment screws in the surface mount backbox. Use the M4 mounting pan head 

screws to attach the collar to the surface mount backbox. Refer to the instructions for the flush mount 

backbox above.

Paradigm Wall Mount Backboxes

n

o

it

p

ir

c

s

e

D

l

e

d

o

M

P-LCD-FBB

Paradigm Touchscreen flush mount backbox

P-LCD-SBB

Paradigm Touchscreen surface mount backbox

N o t e :

A special trim ring is available to cover any excess rough-in gap. Contact ETC or 

your ETC Dealer for availability.

M3 depth 

adjustment 

screw

M4 

mounting 

screw

Summary of Contents for Unison Paradigm P-LCD-FBB

Page 1: ...r LinkPower and Auxiliary power or PoE Power over Ethernet 802 3af Echelon LinkPower LinkConnect control network utilizing Belden 8471 or approved equal and 24 Vdc Auxiliary power two 16 AWG 1 5mm2 wires PoE Power Over Ethernet 802 3af utilizing Category 5 cable or approved equal All control wiring should be installed and terminated by a qualified installer and should follow standard wiring instal...

Page 2: ...essary wiring The PCB consists of three parts PCB with female RJ11 LinkPower connector 24 VDC Aux connector and ground spade RJ45 with punch down wire termination Mounting bracket and screws CAUTION Only one network type may be connected to the touchscreen not both Damage may occur if both power types Auxiliary Power and PoE are connected to the touchscreen ETC requires that all back boxes be grou...

Page 3: ...he red and black Auxiliary power pigtail wires Using two Wago connectors connect the typically red installed wire s with red pigtail wire and connect the typically black installed wire s with black pigtail wire as shown above Step 4 Plug the Auxiliary power connector into the Aux power receptacle on the termination PCB Step 5 A ground connection is required for all Touchscreen assemblies If the ba...

Page 4: ...rvice position to the operation position lift up at the bottom and rotate the bottom inward Step 5 Push firmly in and down on the bottom corners of the bezel until it audibly snaps onto the collar When properly installed the Touchscreen should not easily unsnap from the collar Step 6 To remove the Touchscreen insert a flat bladed screwdriver into the pry slot and unsnap the Touchscreen from the co...

Reviews:

Related manuals for Unison Paradigm P-LCD-FBB