EG V1(BL) 

Self-Monitoring Blood Glucose System 

 

 

Quick Reference Guide 

 

 

 
 
 

 

Summary of Contents for EG V1(BL)

Page 1: ...1 EG V1 BL Self Monitoring Blood Glucose System Quick Reference Guide...

Page 2: ...emory 1 Press X until turning the meter on Press W once again and release to enter the setting mode 2 The last 2 digits of the year flash at the center of the display Press X to adjust the year and Pr...

Page 3: ...W to confirm the setting 5 Press X to adjust value of hype and Press W to confirm the setting 6 When setting is finished the display will be back to the testing mode of flashing strip Hypo setting are...

Page 4: ...display will show no CODE the first time batteries are installed 2 Insert the code card into the slot The screen displays OK 3 The code number will be shown on the display Make sure the code number o...

Page 5: ...ueeze the bottle until a tiny drop forms at the tip of the bottle Touch the drop to the Blood collection area at the end of the test strip Do not put control solution on top of the test strip When you...

Page 6: ...y Don t remove the test strip yet Check if the reading falls within the range printed on the test strip bottle 7 Remove the test strip and throw it away after you have compared the reading to the rang...

Page 7: ...Lancet Into The Lancing Device You must first load the lancet into the lancing device to get it ready for use 1 Unscrew the Cap 2 Insert the lancet into the lancing device firmly then twist off the pr...

Page 8: ...8 Select 1 3 for soft or thin skin 4 5 for average and 6 8 for thick or calloused skin 3 Recap the front cap 4 Select the desired penetration depth...

Page 9: ...ding barrel of the lancing device until it clicks and then release Now the lancing device is ready Do not prick your finger until your meter and strip are prepared 6 Set the lancing device aside until...

Page 10: ...The meter turns on 3 Swab the blood collection area on your finger with an alcohol swab Please wait at least 5 seconds until the intended area is dry and clean before sampling the blood 4 Place the l...

Page 11: ...ip Do not put blood on top of the strip Be sure to get enough blood on the strip s reaction zone Otherwise an inaccurate reading may result 7 The meter will beep when enough blood has entered the stri...

Page 12: ...clear adjustable tip against the forearm 1 This graphic shows where the meter cleared for alternative site testing Running A Blood Glucose Test With Blood From Your Forearm Check with your healthcare...

Page 13: ...a drop of blood sample 5 Press the trigger button to activate the lancing device 6 Hold the device against forearm or palm and increase pressure until the blood sample size is sufficient Running A Blo...

Page 14: ...le lancets according to the recommendations of your healthcare professional 1 Unscrew and remove the adjustable cap Without touching the used lancet stick the lancet tip into its protective cover Grip...

Page 15: ...Press W to view the previous results in order from the latest to the earliest 3 Press X once again to view averages of 7 day test result 4 Press W to review averages of 14 day 30 day and 90 day test r...

Page 16: ...of alarm 2 Press W to set On for the first alarm 3 Press W to adjust time and press X to confirm the setting 24 hour clock 4 Press X to confirm the first setting and then get into the second one 5 Re...

Page 17: ...n error message If you have any concerns please contact your local dealer System fault Action Replace the batteries first If 001 ERROR appears again please contact your local dealer Humidified Used st...

Page 18: ...tion with temperature between 10 C 40 C 50 F 104 F The Lt and thermometer icon appears Temperature is too low outside the required range of 10 C 40 C 50 F 104 F This alerts users that an incorrect res...