1.

Air Quality Components 

2.

Component Function

3.

Programming

4.

Data Logging

5.

Transferring data to a PC or MAC

6.

Wiring & Technical Data

7.

History of Air Quality

8.

Comparison with CO2

9.

Portable class room application

1.

AIR QUALITY COMPONENTS

 
a)

Order number AQT-S-2000.  A cream coloured

instrument resembling a thermostat called the air
quality monitor or AQT. 
This instrument can be ordered factory programmed
or programmed in the field with a hand-held module.

b)

Order number HHM-AQ.  A black instrument

with keypad and alpha-numeric display, called a
hand-held module or HHM.  
If you wish to log data or modify the program of
AQT-2000’s you will need one of these.  Only one
of these will be required per site or per service
representative.

c)

Order number AQT-DEMO-KIT.  A black

sample case containing a pre-wired power module
and analogue meter connected to a hand held module
and air quality monitor.  
This is a convenient way to test drive the AQT-2000
to verify to yourself that it is effective in your
installation.  Since it is complete with a highly visible
readout indicator it is a very effective way to provide
client demonstrations.      

d)

Order number AQT-SERIAL-KIT.  Cables and

software to permit data from the air quality system to
be downloaded to a PC and graphed.  

2.

COMPONENT FUNCTION

 
a)

The AQT-2000 monitors and controls air

quality.  It senses volatile organic compounds,
VOC’s.  People breath out VOC’s, including
ketones.  Building materials out-gas VOC’s such as
formaldehyde from carpets and chip board.  The
AQT-2000 is therefore a good sensor of air quality
deterioration due to both occupancy and chemicals in
the work place.  
If you choose CONTROLLER while setting up the
AQT-2000 it will respond quickly to any worsening
of air quality but react slowly to improvements in air
quality.  This is to insure that any contaminants are
flushed from the monitored space.  CONTROLLER
should be selected for applications such as portable
classrooms where one AQT-2000 will be directly
connected to a fresh air damper actuator to control air
quality.
If you choose TRANSMITTER it will produce an
analogue voltage or current signal proportional to the
selected range of air quality you wish to monitor .
TRANSMITTER should be selected if several AQT-
2000 monitors will transmit signals to a central
control system which will decide on the appropriate
action to take to control air quality. 

ENERCORP

 

instruments ltd

25 Shorncliffe Rd, Toronto, ON, M9B 3S4, Canada
Tel(416)231-5335

Fax (416)231-7662

Tel(800)ENERCORP

Fax (877)ENERCORP

Reviews: