background image

X2000 SwimCross™ System

O W N E R'S  M A N U A L  50H Z

by Endless Pools

®

Summary of Contents for X2000 SwimCross

Page 1: ...X2000 SwimCross System OWNER S MANUAL 50HZ by Endless Pools...

Page 2: ...________________ DATE INSTALLED ______________________________________ DEALER _____________________________________________ ADDRESS ____________________________________________ TELEPHONE _____________...

Page 3: ...ALL OFF MEMORY ON 16 SPA SIDE CONTROL PANEL 17 SETTINGS 17 INVERT SCREEN 19 TEMPERATURE CONTROL 19 JETS CONTROL 19 LIGHT CONTROL 20 FILTER CYCLES 20 POLLING 20 ALL OFF MEMORY ON 20 WI FI IN TOUCH OPT...

Page 4: ...qualified service personnel Do not attach an external antennae to an exercise system audio system unless installed by a licensed electrician in accordance with your National Electric Code WARNING To...

Page 5: ...high blood pressure circulatory system problems or diabetes should consult a physician before using exercise system UNCLEAN WATER Keep the water clean and sanitized with correct chemical care The reco...

Page 6: ...of the control box by the exercise system owner will void the warranty If you have an operational problem carefully go through the steps outlined in the Troubleshooting section If you are not able to...

Page 7: ...to a source of water Do not use the exercise system above a finished living area due to the risk of water damage The exercise system is not designed for in floor installation However it is compatible...

Page 8: ...When a small reach is needed for the final placement of your system a boom truck is ideal Atelehandler vehicle can off load traverse property and place your system in a more challenging situation or...

Page 9: ...concrete pad or structurally sound deck able to support the dead weight found in the specification chart on the back page WARNING The X2000 Model must not be shimmed in any manner 10 cm 226 cm 610 cm...

Page 10: ...our exercise system has been filled with water turn it on and test all of the circuit breakers IMPORTANT If breaker immediately trips verify that the wires are correctly connected Breaker should be te...

Page 11: ...nds then push the breaker switch to the OFF down position to ensure that it has completely disengaged then push the breaker switch to the ON up position If you don t wait 30 seconds the fitness system...

Page 12: ...he T spacer then remove the T spacer Loosen the 4 screws on the right side corner spacer but do not remove 3 Lift panel and slide left until panel is no longer behind corner 4 While holding panel firs...

Page 13: ...side Water Feature Levers adjust the amount of water that flows from the water features Jet pump 1 must be on for water feature to work 4 Swim side Water Feature Levers adjust the amount of water that...

Page 14: ...ystem is equipped with two air valves The air valves will add or remove air to the hydromassage jet system Rotate valve to see which hydromassage jets are affected QUICK START UP INSTRUCTIONS BEFORE Y...

Page 15: ...of the spa side is complete To turn off the jets press the jets button on the spa side control panel If you do not feel a steady stream of water from your jets refer to the instructions for priming th...

Page 16: ...confirm When in Economy mode the heating set point will be reduced by 11 C 20 F which means that the heating system will not come on during the set time unless the temperature falls 11 C 20 F below th...

Page 17: ...ttons to choose the setting that you want to adjust and select it by pressing middle left lit button Use the or buttons to change the parameters and middle left lit button to move between parameters P...

Page 18: ...and condition of your exercise system and on outside temperatures The set temperature of the swim side water will automatically be 29 5 C 85 F the first time power is applied This is the setting prog...

Page 19: ...e devices See Wi Fi in the spa side Settings section to connect your swim side to your home Wi Fi network For instruction on how to download theApp to your device search gecko in touch in yourApp stor...

Page 20: ...ing set point will be reduced by 20 F 11 C which means that the heating system will not come on during the set time unless the temperature falls 20 F 11 C below the set temperature The filtration sche...

Page 21: ...he time format change the year date and time Use the or buttons to choose the setting that you want to adjust and select it by pressing middle left lit button Use the or buttons to change the paramete...

Page 22: ...atures The set temperature of the spa side water will automatically be 38 0 C 100 F the first time power is applied This is the setting programmed at the factory After the spa side has been set up and...

Page 23: ...d for 1 minute purge cycle back to back FILTER CYCLE SUSPENSION The filter cycle will be suspended every time a jet pump or light is activated manually during the filter cycle time The suspension will...

Page 24: ...ir proper containers Don t inhale fumes or allow chemicals to come in contact with your eyes nose or mouth Wash your hands immediately after use Follow the emergency advice on the product label in cas...

Page 25: ...er iron and manganese will increase Minimize evaporation by keeping the cover on the exercise system whenever possible High iron or copper content in the water may produce green or brown stains on the...

Page 26: ...FAC chlorine does not have an odor whereas combined spent chlorine chloramines has a strong chlorine odor that can be eliminated by shocking the water IMPORTANT There are several forms of stabilized...

Page 27: ...quires changing due to the buildup of soap in the water Typically soap will cause the exercise system water to foam when the jets are used Soap is introduced into the exercise system water from two so...

Page 28: ...to keep your exercise system filter cartridges clean and free of particles to ensure proper water flow Clean filters enables the hydrotherapy system to function properly and allows for more efficient...

Page 29: ...side the exercise system remains at the selected temperature The energy efficiency of the exercise system may also decrease during these cold periods as the heater will cycle more frequently As an add...

Page 30: ...ners out of the reach of children and use care when applying EXERCISE SYSTEM CABINET All exercise systems use the exclusive all climate cabinet designed for years of performance The unique design is m...

Page 31: ...following factors Thermal overload Although mass produced not all thermal overload cutoffs are exactly the same Some are more sensitive than others and will shut the pump off at lower temperatures Hi...

Page 32: ...r Overused or old water Clean filters Shock exercise system with sanitizer Add sanitizer Adjust pH and or alkalinity to recommended range Run jets pump s and clean filters Drain and refill the exercis...

Page 33: ...cartridge Jet blocked Clogged suction or skimmer basket Open air valve Open any closed water valves Clean filter cartridge Remove jet face eyeball and clean orifice Clean suction cover or skimmer bas...

Page 34: ......

Page 35: ......

Page 36: ...5V 3N 24A 50HZ Three phase 24 amp phase GFCI protected circuit F o o t p r i n t d i m e n s i o n s S w i m s i d e e f f e c t i v e f i l t e r a r e a H e i g h t S w i m s i d e h e a t e r W a t...

Reviews: