background image

ENDA EI141 PROGRAMMABLE INDICATOR

 Thank you for choosing 

ENDA EI141

 Programmable Indicator.

SET

 EI141

ENDA

P

ROGRAMMABLE INDICATOR

 

EI141

-

E

-09-160217

Order Code 

:

  

EI

141 

-

           

     

1 - Supply Voltage

     

     

230VAC...230V AC

     

     

24VAC.....24V AC 

     

     

12VAC.....12V AC 

     

     

SM...........9-30V DC /7-24V AC 

1/3

SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.

Şerifali Mah. 

 Y.Dudullu  34775

ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
url : www.enda.com.tr

Barbaros Cad. No:18

ENDA

TM

Please read this document carefully before using this product. The guarantee will be invalidated if the device is damaged by not 
following instructions detailed in the manual. The company shall not be responsible for any damage or losses however caused, 
which may be experienced as a result of the installation or use of this product.  

-

  35x77mm sized.

-

  4 digits display.

-

  Easy to use by front panel keypad.

-

  Display scale can be adjusted between -1999 and 4000.

-

  Decimal point can be adjusted between 1. and 3. digits.

-

  Measurement unit can be displayed.

-

  Selectable four different standard input types (0-20mA, 4-20mA, 0-1V, 0-10V)

-

  User can calibrate the device according to specified input type.

-

  Sampling time can be adjusted in four steps. 

-

  Stores maximum and minimum measurement values.

-

  The maximum or the minimum values can be hold on the display.

-

  Current and voltage calibration can be performed.

-

  Parameter access protection on 3 levels.

-

  Easy connection by removable screw terminal.

-

  CE marked according to European Norms.  

TECHNICAL SPECIFICATIONS 

ENVIRONMENTAL CONDITIONS

 Height

 Max. 2000m

 Ambient

 

/

 S

torage 

T

emperature

 Max. 

R

elative 

H

umidity

0 ... +50

 

°C/-25 ... +70°C  (With no icing) 

Rated 

P

ollution 

D

egree

80% Relative humidity for temperatures up to 31°C, decreasing linearly to 50% at 40°C.

According to EN 60529                Front panel :    IP65
                                                     Rear panel  :    IP20

 Do not use the device in locations subject to corrosive and flammable gases.

1

 Supply

 Power 

C

onsumption

Max. 7VA

2.5mm² screw-terminal connections

 Wiring

 Date 

R

etention 

 EMC

 Safety 

R

equirements

 EN 61326-1: 2013  

EEPROM (Min. 10 years)

 EN 61010-1: 2010 P

 ( ollution degree 2, overvoltage category II, measurement category I)

ELECTRICAL CHARACTERISTICS

 230V AC +10  -20  or 12/24V AC ±10 , 50/60Hz or optional 

.

%

%

%

9-30V DC / 7-24V AC ±10% SMPS

EI141 Can not be used if measurement category II, III or IV  is required.

While the current measuring mode, input impedance becomes 5

Ω

 . Therefore, in current mode, the device must not be connected any 

voltage input. Otherwise, the device is broken. While the device is running in the voltage measurement mode and if required to change 
to current measurement mode, then firstly the voltage inputs must be removed and after that, input type must be changed to one of the 
current measurement  modes.

Input Type

 0-1V DC voltage

 0-10V DC voltage

 0-20mA DC current

 4-20mA DC current

 Input Empedance

Approx. 11k

Ω

  (terminal voltage limits:  min. =  -2V,  max. = 30V)

Approx.

Ω

(terminal voltage limits:  min. =  -2V,  max. = 30V)

 11k   

 

Approx.

Ω

 5       (applicable terminal voltage is max. 50mA.)

Approx.

Ω

(applicable terminal voltage is max. 50mA.)

 5       

0V

±0,5% (of full scale) 

0V

±0,5% (of full scale)

0mA

±0,5% (of full scale)

0mA

±0,5% (of full scale)

 1.1V

 14V

 25mA

 25mA

 Min.

Max.

Measurement 

R

ange

Measurement 

A

ccuracy

HOUSING

 Housing 

T

ype

 Suitable for flush-panel mounting according to DIN 43 700.

 Dimensions

 W77xH35xD71mm 

 Weight

 Approx. 250g (after packing)

 Enclosure 

M

aterial

 Self extinguishing plastics 

 While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used.