SYSTEM 7000 

 
 
 
 
 
 
 
 
 
 

 

7941 

 

EIGHT INPUT 

HIGH POWERED  

UHF TRANSMITTER

 

 

 

INSTALLATION AND PROGRAMMING 

INSTRUCTIONS 

Summary of Contents for 7256

Page 1: ...SYSTEM 7000 7941 EIGHT INPUT HIGH POWERED UHF TRANSMITTER INSTALLATION AND PROGRAMMING INSTRUCTIONS ...

Page 2: ...NG CONNECTION DETAILS 6 5 INPUT PROGRAMMING 7 6 ID 15 7 CON 15 8 TYPE 16 9 MODE 17 10 TXD 18 11 QUIT 18 12 LOAD DEFAULT VALUES 19 13 INTERNAL INPUT WIRING 20 14 ADDING AN INPUT HAND PUSH MODE INTO THE IRIS RADIO RECEIVER 21 15 ADDING AN INPUT CONTACT MODE INTO THE IRIS RADIO RECEIVER 23 16 ADDING A RESET INPUT HAND PUSH MODE INTO THE IRIS RADIO RECEIVER 25 17 ASSIGNING TEXT DESCRIPTION FOR AN INPU...

Page 3: ... if the contact is programmed as normally open or removed if normally closed see Figure 4 on page 19 for details On an input activation a signal will be transmitted to the receiver and displayed in the format programmed i e Alarm Zone Area 1 for an input that has been set as an Alarm input and programmed with the text description Zone Area 1 2 Tools Test Equipment 2 1 Only standard hand tools are ...

Page 4: ...ion and requirements Please note both the eight input transmitter and the IRIS receiver will require an external power supply Figure 1 shows a typical IRIS radio system whilst Figure 2 shows an alternative system using a Single Channel 7703 Receiver Figure 1 7941 Half Watt Txer 7941 Half Watt Txer 7941 Half Watt Txer 7256 IRIS Rxer Eight Input Data Transmissions Eight Input Data Transmissions ...

Page 5: ... 2015 EMS Security Group Ltd All rights reserved TSD248 Iss 2 25 06 15 AJM 5 Figure 2 7941 Half Watt Txer 7941 Half Watt Txer 7941 Half Watt Txer 7703 Rxer Eight Input Data Transmissions Eight Input Data Transmissions ...

Page 6: ...r physical connection details are as follows COMPUTER ISOLATED RS 232 PORT PIN 2 TX OUT PIN 3 RX IN PIN 5 COMMON CONNECT 4 2 All Computer to HyperTerminal connections are shown below in Figure 3 Figure 3 TAMPER LOOP 0V 12V DC SUPPLY COMMON CONNECT RX RX RX TX COMMON IN OUT CONNECT ISOLATED RS485 ISOLATED RS232 2 3 5 TO POWER SUPPLY 9 PIN SERIAL CONNECTOR ...

Page 7: ... data or a hand push device which must be used for certain types of transmitted data and does not transmit restore data MODE A full explanation of all input settings and the operation of the inputs if selected is described in more detail in the following paragraphs under their menu commands headings 5 2 The inputs have their settings defaulted to the following parameters Inputs 1 8 ID A0001 A0008 ...

Page 8: ...SYSTEM 7000 2015 EMS Security Group Ltd All rights reserved TSD248 Iss 2 25 06 15 AJM 8 Now enter your desired connection description Then click on the OK button and the screen will change to the following ...

Page 9: ...STEM 7000 2015 EMS Security Group Ltd All rights reserved TSD248 Iss 2 25 06 15 AJM 9 Now select the Comm Port required as below Then click on the OK button and the screen will change to the following screen ...

Page 10: ...7000 2015 EMS Security Group Ltd All rights reserved TSD248 Iss 2 25 06 15 AJM 10 Now select the following settings Once completed click on the Apply button and then the OK button The screen will change to display ...

Page 11: ...EMS SYSTEM 7000 2015 EMS Security Group Ltd All rights reserved TSD248 Iss 2 25 06 15 AJM 11 Now select Call and Disconnect and the screen will change to display ...

Page 12: ... 7000 2015 EMS Security Group Ltd All rights reserved TSD248 Iss 2 25 06 15 AJM 12 Now select File and Properties The screen will change to display Now select the Settings tab and the screen will change as below ...

Page 13: ...015 EMS Security Group Ltd All rights reserved TSD248 Iss 2 25 06 15 AJM 13 The Settings should be set as follows Once the settings are as above click on the ASCII Setup button and check that the settings are as follows ...

Page 14: ...he settings are as above click on the OK button then on the next window click on the OK We can now establish a connection by selecting Call and Call as below Once completed HyperTerminal is configured Please Note To prevent future reconfiguration the HyperTerminal session can be saved for future use ...

Page 15: ...ready programmed into the IRIS unit 6 3 To change the inputs identification number from the command menu type id and press the enter key The display will then show Input No 1 ID code hex is A0001 Change Y N To change the ID press Y and then the enter key the display will now show New ID Code hex Enter the new ID code and press enter If the hex number is a valid number the display will change to sh...

Page 16: ...nput requires it s mode setting programmed to hand push and should be added into the IRIS as an opposed action hand push 8 6 LOCAL If selected on triggering this input a local alarm transmission will be sent to the IRIS receiver This input can have it s mode setting set to either hand push or contact and can be added into the IRIS as an opposed action hand push or N O contact operated transmitter ...

Page 17: ...peration of the input The unit has two modes contact and hand push The default for all inputs is set to contact 9 2 If contact is selected the input should be added into the IRIS receiver as a N 0 contact operated transmitter this will then cause the input to transmit data on both an activation of the input and the reinstating of the input This will be shown on the IRIS when its being reset as it ...

Page 18: ...transmit three bursts of call in data To enter this function type txd from the command menu and press the enter key The display will then show Transmit Call Ins Call in 08EA0000 Call in 08EA0000 Call in 08EA0000 Call in 08EA0001 Call in 08EA0001 This is call in data for input 1 Call in 08EA0001 This is then repeated for all active inputs showing each of the inputs ID s in three transmitting bursts...

Page 19: ...systems inputs Default values for the inputs are as follows Inputs 1 8 ID A0001 A0008 Con Normally Open Type Alarm Mode Contact 12 2 To change all of the inputs to their default settings type load defaults and press the enter key The display will now show Load Default Values Y N Press the Y key and then enter the display will then change to show Please Wait The system will then return to the comma...

Page 20: ...EMS SYSTEM 7000 2015 EMS Security Group Ltd All rights reserved TSD248 Iss 2 25 06 15 AJM 20 13 Internal Input Wiring Connection Drawing Figure 4 ...

Page 21: ...the engineering default PIN 221100 and then press the button the screen will now display Main Menu Pins Access System Support 2 Help 13 27 14 5 Press the button until screen displays Time and Date Radio Setup Output Setup 2 Help 16 37 14 6 Press the 1 button and the screen will display Radio Setup Add Transmitter Txer Details 2 Help 16 37 14 7 Press the 1 button and the screen will display Add Tra...

Page 22: ...e the screen will change to display Operate Transmitter Again or press Escape to cancel 16 38 14 12 Using the same operation once again generate a transmission after a short period of time the screen will change to display Hand Push 001 Added Push any key 16 38 14 13 You may now add additional inputs by repeating the actions detailed If no further inputs are to be added then escape from this menu ...

Page 23: ...e screen will now display Enter Your PIN For Menus _ Done Del 13 26 15 4 Enter the engineering default PIN 221100 then press the button and the screen will display Main Menu Pins Access System Support 2 Help 13 27 15 5 Press the button until the screen displays Time and Date Radio Setup Output Setup 2 Help 16 37 15 6 Press the 1 button and the screen will display Radio Setup Add Transmitter Txer D...

Page 24: ...ng upon N O or N C input and the screen will display Reset Transmitter NOW 16 38 15 12 After a short period of time the screen will change to display Operate Transmitter Again or press Escape to cancel 16 38 15 13 Using the same operation once again generate a transmission after a short period of time the screen will change to display Contact 001 Added Push any key 16 38 15 14 You may now add addi...

Page 25: ... should now display System Clear 01 10 93 13 26 16 2 Turn the control keyswitch to the RESET position The screen will now display SYSTEM RESET 13 26 16 3 Press the 0 key and the screen will display Enter Your PIN For Menus _ Done Del 13 26 16 4 Enter the engineering default PIN 221100 and press the button and the screen will now display Main Menu Pins Access System Support 2 Help 13 27 16 5 Press ...

Page 26: ...ease all buttons NOW 16 38 16 11 After a short period of time the screen will change to display Operate Transmitter Again or press Escape to cancel 16 38 16 12 Using the same operation once again generate a transmission after a short period of time the screen will change to display Interrogator 001 Added Push any key 16 38 16 13 You may now add additional inputs by repeating the actions detailed I...

Page 27: ...reen will display Txer Details Name by Number Name by Tx 2 Help 16 37 17 6 Press the button and the screen will display Name by Number Name by Tx View Names 2 Help 16 37 17 7 Press the 1 button and the screen will display Operate Transmitter NOW or press Escape to cancel 16 38 17 8 Generate a transmission by activating the input that requires re texting and the screen will display Release all butt...

Page 28: ... a blank space into the new device name being entered 3 Exits to the previous menu 4 Moves the alphabet wheel of characters to the Left by one character space at a time 5 Enters the character in the centre directly above the character selector 6 Moves the alphabet wheel of characters to the Right by one character space at a time 7 Moves the flashing cursor to the left through the new device name b...