ELECTRIC FRYERS 

 

 

 

 

Kasap Tip Dik Buzdolapları 

 

 

 

 

 

 

 

CONTENTS 

GENERAL INFORMATION 

Page  2

 

A1 

PRODUCT DESCRIPTION 

Page 

A2 

TECHNICAL INFORMATION 

Page 

A3 

TRANSPORTATION 

Page 

A4 

UNPACKING 

Page 

INSTALLATION 

 

 

 

 

Page  4 

SAFETY INSTRUCTIONS 

 

 

 

Page  5

 

OPERATION   

 

 

 

 

Page  6

 

CLEANING & MAINTENANCE  

 

 

Page  7 

TROUBLESHOOTING   

 

 

 

Page  8 

SPARE PART LIST- EXPLODING DRAWING   

Page  9 

ELECTRIC CIRCUIT SCHEMA  

 

 

Page  17

 

 

 

Summary of Contents for EMP.7FE010

Page 1: ...ESCRIPTION Page 3 A2 TECHNICAL INFORMATION Page 3 A3 TRANSPORTATION Page 4 A4 UNPACKING Page 4 B INSTALLATION Page 4 C SAFETY INSTRUCTIONS Page 5 D OPERATION Page 6 E CLEANING MAINTENANCE Page 7 F TROUBLESHOOTING Page 8 G SPARE PART LIST EXPLODING DRAWING Page 9 H ELECTRIC CIRCUIT SCHEMA Page 17 ...

Page 2: ...cause of disobeying instructions and regulations wrong connections Unauthorized intervention to appliance invalidates the warranty 1 This instruction manual should be kept in a safe place for future reference 2 Installation should be made in accordance with ordinances and security rules of that country by a qualified service personnel 3 This appliance has to be used by trained person 4 Please turn...

Page 3: ... kg Packaging Dimensions mm EMP 7FE010 400x730x285 23 480x800x590 EMP 7FE020 800x730x285 51 780x830x1050 EMP 9FE010 400x900x850 61 430x950x1050 EMP 9FE020 800x900x850 138 830x950x1050 A2 TECHNICAL INFORMATION Product Code Electric Entrance Cable mm Power KW Capacity lt EMP 7FE010 400 V AC 3N PE 5x4 11 18 EMP 7FE020 400 V AC 3N PE 5x4 22 2x18 EMP 9FE010 400 V AC 3N PE 5x4 12 24 EMP 9FE020 400 V AC ...

Page 4: ...n who will serve for installation and service for the appliance must be professional on this subject and must have installation and service licenses by the company Connection to Electric Power Supply must be done by authorized person Please be sure that the voltage connected to appliance must be equal with the voltage which is on appliance s label This appliance must be connected to an earthed out...

Page 5: ...se the appliance without suitable protective equipments Because of any reason if there is a fire or flame flare where the appliance is used turn off all gas valves and electric contactor switch quickly and use fire extinguisher Never use water to extinguish the fire All the damages because of not having earthing connection will not be on warranty Level of oil mustn t be less than minimum level Oth...

Page 6: ...rt to work and indicator lamp that is on thermostat signals When the oil temperature reaches indicator temperature heaters are disabled through the agency of limit thermostat When the oil temperature is lower than indicator temperature the limit thermostat steps in and heaters start to work Put the materials that will be fried into the tank in the basket during oil heating After putting the materi...

Page 7: ...se electric motor may get damaged While cleaning the inside of the fryer lift the heater handle unsettle the heaters that are in the tank and take them to vertical position Take off the baskets and filter that are in the tank PERIODIC CLEANING AND MAINTENANCE Maintenance should be done by qualified person Get the periodic maintenance of the appliance once in every 15 days Clean the oil tank in per...

Page 8: ...PPLIANCE STOPPED 1 If the oil temperature reaches to 230ºC while the appliance is operating limit thermostat will stop the circuit In this situation the appliance can not be operated Leave the oil to be cooled to operate again Then take off the thermostat switch that is on front panel and press the red button with a thin tool 2 The appliance can stop due to low voltage In this situation check the ...

Page 9: ...9 ELECTRIC FRYERS Kasap Tip Dik Buzdolapları G SPARE PART LIST EXPLODING DRAWING EMP 7FE010 ...

Page 10: ...NGE RING Y EMP 7FE010 012 13 BUTTON Y EMP 7FE010 013 14 EVACUATION HOSE Y EMP 7FE010 014 15 VALVE Y EMP 7FE010 015 16 SWITCH Y EMP 7FE010 016 17 CHROME HINGE RING Y EMP 7FE010 017 18 LOCK SPRING Y EMP 7FE010 018 19 RESISTANCE CONNECTION SHEETMETAL RIGHT Y EMP 7FE010 019 20 LOCK CONNECTION YELLOW NUT Y EMP 7FE010 020 21 FEET Y EMP 7FE010 021 22 THERMOSTAT 135 180 Y EMP 7FE010 022 23 LOCK HANDLE Y E...

Page 11: ...11 ELECTRIC FRYERS Kasap Tip Dik Buzdolapları G SPARE PART LIST EXPLODING DRAWING EMP 9FE010 ...

Page 12: ...NGE GROUP Y EMP 9FE010 014 15 VALVE Y EMP 9FE010 015 16 SWITCH Y EMP 9FE010 016 17 CHROME HINGE RING Y EMP 9FE010 017 18 LOCK SPRING Y EMP 9FE010 018 19 RESISTANCE CONNECTION MIDDLE BOTTOM SHEETMETAL Y EMP 9FE010 019 20 LOCK CONNECTION YELLOW NUT Y EMP 9FE010 020 21 FEET Y EMP 9FE010 021 22 THERMOSTAT 135 180 Y EMP 9FE010 022 23 LOCK HANDLE Y EMP 9FE010 023 24 BUTTON BUFFER Y EMP 9FE010 024 25 THE...

Page 13: ...13 ELECTRIC FRYERS Kasap Tip Dik Buzdolapları G SPARE PART LIST EXPLODING DRAWING EMP 7FE020 ...

Page 14: ...BUTTON Y EMP 7FE020 013 14 DRAINAGE PIPE Y EMP 7FE020 014 15 VALVE Y EMP 7FE020 015 16 SWITCH Y EMP 7FE020 016 17 CHROME HINGE RING Y EMP 7FE020 017 18 LOCK SPRING Y EMP 7FE020 018 19 RESISTANCE CONNECTION SHEETMETAL RIGHT Y EMP 7FE020 019 20 LOCK CONNECTION YELLOW NUT Y EMP 7FE020 020 21 FEET Y EMP 7FE020 021 22 THERMOSTAT 135 180 Y EMP 7FE020 022 23 LOCK HANDLE Y EMP 7FE020 023 24 BUTTON BUFFER ...

Page 15: ...15 ELECTRIC FRYERS Kasap Tip Dik Buzdolapları G SPARE PART LIST EXPLODING DRAWING EMP 9FE020 ...

Page 16: ...VALVE Y EMP 9FE020 015 16 SWITCH Y EMP 9FE020 016 17 CHROME HINGE RING Y EMP 9FE020 017 18 LOCK SPRING Y EMP 9FE020 018 19 RESISTANCE CONNECTION SHEETMETAL RIGHT Y EMP 9FE020 019 20 LOCK CONNECTION YELLOW NUT Y EMP 9FE020 020 21 FEET Y EMP 9FE020 021 22 THERMOSTAT 135 180 Y EMP 9FE020 022 23 LOCK HANDLE Y EMP 9FE020 023 24 BUTTON BUFFER Y EMP 9FE020 024 25 THERMOCUPL CONNECTION SHEETMETAL Y EMP 9F...

Page 17: ...17 ELECTRIC FRYERS Kasap Tip Dik Buzdolapları H ELECTRIC CIRCUIT SCHEMA EMP 7FE010 T1 LS C1 L1 R1 Thermostat 135 180ºC Limit Switch Contactor Thermostat signal lamp Resistance ...

Page 18: ...CTRIC FRYERS ELEKTRİKLİ FRİTÖZLER Kasap Tip Dik Buzdolapları H ELECTRIC CIRCUIT SCHEMA EMP 7FE020 T1 T2 LS1 LS2 C1 C2 L1 L2 R1 R2 Thermostat 135 180ºC Limit Switch Contactor Thermostat signal lamp Resistance ...

Page 19: ...19 ELECTRIC FRYERS Kasap Tip Dik Buzdolapları H ELECTRIC CIRCUIT SCHEMA EMP 9FE010 T1 LT LS C1 L1 R1 Thermostat 135 180ºC Limit thermostat 230ºC Limit Switch Contactor Thermostat signal lamp Resistance ...

Page 20: ...Lİ FRİTÖZLER Kasap Tip Dik Buzdolapları H ELECTRIC CIRCUIT SCHEMA EMP 9FE020 T1 T2 LT1 LT2 LS1 LS2 C1 C2 L1 L2 R1 R2 Thermostat 135 180ºC Limit thermostat 230ºC Limit Switch Contactor Thermostat signal lamp Resistance 4000W 230V ...

Reviews: