background image

EMPAVA APPLIANCE INC.
Add: 15253 Don Julian Rd, City of Industry, CA 91745
Tel: 888-682-8882
www.empava.com

RANGE HOOD

Installation and Operation

Manual

Summary of Contents for EMPV-30RH05

Page 1: ...EMPAVA APPLIANCE INC Add 15253 Don Julian Rd City of Industry CA 91745 Tel 888 682 8882 www empava com RANGE HOOD Installation and Operation Manual ...

Page 2: ... Electron Equipment WEEE directive WEEE should be separately collected and treated If at any time in future you need to dispose of this product please do NOT dispose of this product with household waste Please send this product to WEEE collecting points where available Model No EMPV 30RH05 EMPV 30RH06 Total power 204W Motor power 200W Led Light 2x2W Voltage 120V Frequency 60Hz Filter Steel Baffle ...

Page 3: ...MAIN PARTS NAME Hook Inner duct cover Outer duct cover Vent pipe Blower box Filter Hook Inner duct cover Outer duct cover Vent pipe Blower box Air outlet Glass Filter EMPV 30RH05 EMPV 30RH06 ...

Page 4: ... minimum 27 56 to maximum 31 5 Fig 2 3 In order to get the best performance do not extend the vent pipe too long and try to make the bend of the vent pipe less and straight make sure the vent pipe connection is firm and air proof Fig 3 4 After hanging the range hood on the wall make sure the hood is level and vertical Fig 4 5 The air Outlet is not allowed to connect to chimney flues or combustion ga...

Page 5: ...e air outlet like this picture And use one ST3 9x10 screw to fix the vent pipe Step 2 Matching the hook to the holes of the inner duct cover and fix it well with M4 screws Step 3 Insert the inner duct cover into the outer duct cover Step 4 Matching the holes of the outer duct cover and blower box fix the outer duct cover to the blower box using 8pcs M4 10 screw provided with the fixing tool as the...

Page 6: ...evel using 10mm drill 3 Press the expanding tube provided into the holes 4 Matching the inner duct cover with the holes tighten the inner duct cover with two 5x50 metal screw provided Step 8 Extend the air outlet of the exhaust pipe out of door Try to make the bend of the exhaust pipe is no more than 120 Step5 A ccording to the size of hook key holes 10mm in diameter and 75 85mm in depth Press the...

Page 7: ...hen working press once to enter into delay turn off mode for 3 minutes Press again to increase delay turn off time from 3 59 minutes No operation for 5 seconds the hood will be turn off in 3 minutes Press again to turn off immediately C In standby mode press to change to speed 1 D In standby mode press to change to speed 2 3 E Speeds In standby mode press once to start high speed F Power on off In...

Page 8: ...ith soft brush Replace the filter after it s dry 4 Clean the motor fan and other inside parts once half year or according to use status by QUALIFIED PERSON 5 DO NOT clean motor with water or other liquid To replace Led light Pic 1 Сaution LED light can not replace a new bulb just replace a new LED light assembly Make sure all the control switches are off and the range hood is unplugged Please follow...

Page 9: ... rating Do not connect the air outlet to chimney flues or combustion gas ducts Do not leave naked flames under the hood In case of any damage to power cable replace the broken cable with a new one by qualified person Do clean the hood correctly in accordance with instruction stated or it might cause the possibility of fire accident ...

Page 10: ......

Page 11: ... This Fan With Any Solid State Speed Control Device AVERTISSEMENT NE CONVIENT PAS A DES REGULATEURS DE VITESSE A SEMI CONDUCTEURS GROUNDING INSTRUCTIONS This appliance must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current This appliance is equipped with a cord having a grounding wire with a gro...

Page 12: ...roken replace motor assembly c The fan motor was not properly installed check and make sure it is firmly installed Noise vibration Something dropped into the blower check and clean blower Weak suction a The distance from the range hood to cooking surface is too far make sure the distance between bottom of the hood to cooking surface is minimum 24 to maximum 27 b Windows doors and drafts can effect t...

Reviews: