Page 1: ...BP7358 1 U L Model No CF160 READ AND SAVE THESE INSTRUCTIONS Net Weight 30 6 Lbs RUSTICO Ceiling Fan Owner s Manual CF160RTI00 Rustic Iron with Washed Oak Honey Maple Blades Model Number BP7358 RUSTICO CF160 9 19 07 11 23 AM Page 1 ...

Page 2: ...light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The longer downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for a 9 foot ceiling The shorter downrod must be used for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accident...

Page 3: ...property damage WARNING a Fan motor housing assembly b One upper glass c One ceiling cover d One decorative cover e Five fan blades f Five blade flanges g One hanger bracket h One hanger ball downrod assembly i One 3 1 2 downrod j One decorative cap k One finial nut l One lower glass m One decorative scroll assembly n One light fitter adapter o One light fitter assembly p One remote control transm...

Page 4: ...h buttons turn the lights on and off and controls the light intensities The red indicator light will illuminate while any button is pressed indicating that the battery is good Preset Memory Feature Your remote control receiver is equipped with a preset memory feature The receiv er will remember the light intensity and fan speed when the light and fan are turned off from the wall switch When the wa...

Page 5: ...ircuit breaker box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING How to Assemble Your Ceiling Fan 1 Place the motor housing assembly on a flat surface with the top of the motor facing upwards Place the upper glass over the motor housing assembly aligning the slots ...

Page 6: ...il the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull up on the downrod to make sure the clevis pin is properly installed 4 Remove and discard the three shipping retainers securing the motor hub in the motor housing NOTE Take care not to scratch the fan housing when installing the blade as...

Page 7: ...ace the ceiling cover over the down rod Then reinstall the hanger ball Figure 8 on the downrod as follows Route the four 80 motor leads through the hanger ball and slide the hanger ball over the downrod Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up DOWNROD MOTOR COUPLING HAI...

Page 8: ...nger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall WARNING Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard WARNING To avoid possible fire or shock do not pinch wires between the hanger bal...

Page 9: ...ect the receiver wires to the supply wires and the fan motor wires as follows a Securely connect the green grounding wires from the hanger ball and the hanger bracket to the supply grounding conductor this may be a bare wire or a wire with green insulation b Securely connect the supply white neutral wire to the receiver white AC IN N wire c Securely connect the supply black wire hot wire to the re...

Page 10: ...15 WALL CONTROL BLACK BLACK WHITE BLACK BLACK WHITE HANGER BALL GREEN WIRE GROUND FROM HANGER BALL AND HANGER BRACKET TWO CONDUCTOR CABLE WITH GROUND BLACK HOT WHITE GROUND TO 120 VOLT SUPPLY WHITE BLUE BLUE ORANGE ORANGE WHITE Figure 13 3 Push the wires and connectors up into the outlet box while inserting the receiv er fully into the hanger bracket Position the antenna wire on top of the receive...

Page 11: ... 8 Connect the white wire from the light fitter to the white wire from the motor Figure 16 Connect the black wire from the light fitter to the black wire from the motor Make sure connectors are fully engaged 9 Position the adapter light fitter assem bly over the adapter plate and secure using three 8 32 x 12mm pan head screws Figure 17 BLACK WIRE WHITE WIRE LIGHT FITTER ADAPTER PLATE ADAPTER Figur...

Page 12: ...light on press and release the DN button The light will turn on at the light intensity previously selected 6 To turn the uplight on press and release the UP button The light will turn on at the light intensity previously selected 7 To vary the intensity of the light hold the DN or UP button down until the desired light intensity is reached then release the button Red light should turn on when any ...

Page 13: ... in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accor dance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception whi...

Page 14: ...inst each other or against the interior wall of the switch housing WARNING Make sure main power is turned off 4 Screws holding blades to 4 Tighten screws securely flanges are loose 5 Loose screws in motor housing 5 Check to make sure all screws in motor housing are snug not over tight 3 Fan wobbles 1 Setscrew in motor coupling is 1 Raise coupling cover and tighten excessively not tightened securel...

Page 15: ...3 Flange Set full set for one fan 762723 RTI 24 Harness Assembly Wiring 762704 25 Adapter Fitter 762703 RTI 26 Fitter Assembly Light 763206 27 Glass Lower 762702 28 Glass Upper 762701 29 Cap Decorative 762706 RTI 30 Nut Finial 762707 RTI 31 Downrod 3 1 2 761631 42 32 Receiver Remote Control 762670 2 33 Transmitter Remote Control 762402 Owner s Manual BP7358 1 Before discarding packaging material b...

Page 16: ...or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover any defects malfunctions or failures caused by Repairs by persons not authorized by Emer...