background image

MP60 LED Fresnel CW 

User Manual

Order codes: 

ELUM106 - Black Housing 

ELUM106A - White Housing

Summary of Contents for ELUM106

Page 1: ...MP60 LED Fresnel CW User Manual Order codes ELUM106 Black Housing ELUM106A White Housing ...

Page 2: ... in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available mains supply voltage is between 100 240V AC 50 6...

Page 3: ... 60W cool white COB LED 6500K Manually adjustable beam angle 10 50 6930 Lux 2m full on 1 8kHz refresh rate DMX channels 1 or 2 selectable 0 100 dimming 4 dimming curves in both LED and halogen profiles Linear square law inverse square law and S curve 4 push button menu with LCD display Captive power connection 3 Pin XLR input output Filter frame and barn doors included MP60 LED Fresnel CW Specific...

Page 4: ... 02 09 11 12 08 04 06 07 10 Technical specifications 01 Earth point 02 LCD display 03 Function buttons 04 3 Pin DMX input 05 3 Pin DMX output 06 Captive power connection 07 Fuse T1A 250V 08 Adjustable zoom knob 09 Barn doors 10 Filter frame 11 Hanging bracket 12 Hanging bracket adjustable knob In the box 1 x fixture 1 x user manual ...

Page 5: ...g mode Manual DIMMER00 Manual DIMMER99 Manual DIMMER DimCurve Linear DimCurve Square Dimmer curves DimCurve S Curve DimCurve INV Squa DimCurve LED Halogen selection LampCurv LED LampCurv Halogen LampCurv Display timeout on 30 seconds Display timeout off Reset factory settings Display ON Display OFF Display Fixture Time Version Temp MENU Default Yes Fixture time Software version Temperature ...

Page 6: ... the MENU button To access the DMX channel mode press the MENU button on the front of the unit to show Channel on the LCD display Now press the ENTER button and use the UP and DOWN buttons to choose one of the 1 or 2 DMX channel modes Press the ENTER button to confirm the setting To exit out of any of the above options press the MENU button Operating instructions Channel Value Function 1 000 255 M...

Page 7: ... the MENU button on the rear of the unit to show DimCurve on the LCD display Press the ENTER button and use the UP and DOWN buttons to set the dimming curve required Linear LELinear dimming curve Square LED Square dimming curve INV Squa LED Inverse Square dimming curve S Curve LED S Curve dimming curve Press the ENTER button to confirm the setting To choose between Halogen and LED dimmer curves pr...

Page 8: ...g DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addres...

Page 9: ... 5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion Termination reduces signal transmission problems and interference It is always ad...

Page 10: ...possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmental...

Page 11: ...www prolight co uk MP60 LED Fresnel CW User Manual 11 ...

Page 12: ...www prolight co uk MP60 LED Fresnel CW User Manual 12 ...

Reviews: