background image

NVE5

15

32-

00

 11/

16

Countdown timer 16A with displayEKO05986, EKO05987, EKO05988, EKO05989© Schneider-Electric 2014NVE51532-0011/16

¼

DANGER 
Risk of serious damage to property and per-

sonal injury, e.g. from fire or electric shock, 

due to incorrect electrical installation.

Safe electrical installation can only be ensured if 

the person in question can prove basic knowl-

edge in the following areas:
• Connecting to installation networks
• Connecting several electrical devices
• Laying electric cables
These skills and experience are normally only 

possessed by skilled professionals who are 

trained in the field of electrical installation technol-

ogy. If these minimum requirements are not met 

or are disregarded in any way, you will be solely li-

able for any damage to property or personal inju-

ry.

You can use the countdown timer 16A with display (re-

ferred to below as the 

timer

) to switch loads on for an ad-

justable time. The device will switch the loads back off 

once the set overtravel time has elapsed. The overtravel 

time can range from one minute to eight hours.
A 2-pole switch can be used to switch off the timer and 

the connected loads.
The operating keys are used for setting and operation. 

You can also connect an external push-button. The ex-

ternal push-button can be used to start or end the over-

travel time from a different location.

Countdown timer 16A with display

Operating instructions

EKO05986, EKO05987, EKO05988, EKO05989

For your safety

Getting to know the timer

en

Wiring the timer

Mounting the timer

1

Install the timer in a flush-mounted box.

2

Place the frame on the insert.

3

Press in the snap ring until it presses against the 

frame.

4

Press on the central plate until it audibly clicks into 

place.

Removing the covers

1

Using a suitable screwdriver, press on the marked 

points to loosen the engagement of the central 

plate.

2

Tilt the central plate forward and remove it.

3

Lift out the snap ring using a suitable screwdriver 

and remove it.

4

Remove the frame.

Mounting the timer

A

External push-button

B

Load

L

N

N

A

B

L

N

L

no connection

Start

Use the push-button for two-pole switch-on of the timer.

Timer on / display in OFF status

|

In order to be able to use an additionally connect-

ed external push-button, the function must be set 

after commissioning. Afterwards, the overtravel 

time can be started and ended externally (see 

chapter "Changing settings").

Displays and operating elements

A

Switch

Top:

Timer switched off

Bottom:

Timer switched on

B

Overtravel time

Display dimmed

Overtravel time ended, 

load off 

--

0 minutes

Display bright

Overtravel time activated, 

load on

01.; 02.; 03.; ...20.

1; 2; 3; ...20 minutes

20.; 30.; 40.; 50.

20; 30; 40; 50 minutes

1.0; 1.5; 2.0; ...8.0

1; 1.5; 2; ...8 hours

C

Operating keys

Press briefly:

Overtravel time:

• "-" reduce in steps
• "+" increase in steps

Press and hold:

Overtravel time:

• "-"  reduce  steplessly
• "+" increase steplessly

Press both push-

buttons (> 3 s):

Enter settings menu

Commissioning the timer

A

Switch pushed down

B

Overtravel time not activated, 

display dimmed

B

A

C

B

A

Reviews: