Installation/Care/Use Manual

SwirlFlo

®

 Refrigerated Fountains with FLEXI-GUARD

®

To assure you install this model easily and correctly, PLEASE READ

THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLA-

TION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH

PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After

installation, leave these instructions inside the fountain for future reference.

IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON

FIG. 2

FIG. 1

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES

IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE

BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELEC-

TROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER.

THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS

PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN

FROM THE BUILDING PLUMBING SYSTEM.

IMPORTANT!  INSTALLER PLEASE NOTE.

Installer

NOTE: WATER FLOW

            DIRECTION

BUILDING WATER

            INLET

    SERVICE STOP

(NOT FURNISHED)

1/4" O.D. TUBE

WATER INLET

TO COOLER

3/8" O.D. UNPLATED

COPPER TUBE CONNECT

COLD WATER SUPPLY

NOTE:  WHEN INSTALLING

REPLACEMENT BUBBLER

AND PEDESTAL, TIGHTEN

NUT (ITEM 5 OR 53) ONLY

TO HOLD PARTS SNUG

IN POSITION.  DO NOT

OVER TIGHTEN.

FIG. 3

2

3

4

5

1

36

35

SEE FIG. 4 OR 5

37, 39, 41

38, 40, 41

42

SEE FIG. 11

44

44

FIG. 4

45

46

BASIN

47

48

ERPA2-8RAC, LPTEA8RAC

FIG. 5

51

52

53

ERPA2-8C, LPTEA8C

Summary of Contents for ERPA2-8C

Page 1: ...OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN CREATING AN ELEC TROLYSIS WHICH CAUSESAMETALLIC TASTE ORAN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION ISAVOIDABLE BY USING THE PROPER MATERIALSAS INDICATED ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYST...

Page 2: ... ERPAVR2 8C ERPAVR2 8RAC LPTEA8C LPTEA8RAC FIG 6 PAGE 2 LEGEND A 3 8 O D TUBE CONNECT CHILLER WATER OUTLET B 3 8 O D TUBE CONNECT CHILLER WATER INLET SHUT OFF VALVE BY OTHERS C 1 1 4 TRAP NOT FURNISHED D ELECTRICAL INLET LPTEA8C LPTEA8RAC ...

Page 3: ...S MAY RESULT See Figure 6 LPTEA MODEL Make connections between remote chiller and fountain Outlet port is marked on the chiller 3 8 O D copper tube Install a 3 8 x 3 8 union provided on the marked chiller outlet port Insert the 3 8 unplated copper water line provided into the union Install a 1 4 x 3 8 union provided on the 3 8 copper tube and connect to the 1 4 copper tubing coming from the founta...

Page 4: ...ong Cover Plate Long Bronzetone Speed Nut Basin Swirlflow Basin Swirlflow Bronztone Strainer Screw 10 24 X 62 HHMS Strainer Ferrule Assembly Strainer Ferrule Assy Bronzetone Gasket Tailpipe Gasket Tailpipe Waste Arm Tube Water In Poly Tubing 48 Cut To Length Bubbler VR Model Only Gasket VR Model Only Bubbler Nipple VR Model Only Bolt 5 16 18 x 1 75 Lg Nut Hex 5 16 18 Spacer 51349C 56044C 40322C 45...

Reviews: