background image

 

 

 
 

 

Operating Manual 

SERIES 

HWD15 

Battery powered Display Unit with Rotative Encoder (1250 ppr) 

 

 

 

Easy mounting and operation 

 

Battery operation (no wirings required)  

 

Wear-free measuring principle  

 

LCD display with signs, special characters  

and battery status indicator 

 

„° “-Symbol for angular measurement assignable 

 

Fraction display in inch mode possible 

 

Resolution 0.1 mm or 0.01 mm via parameters 

 

Display inch mode „0.001 Inch“ is possible 

 

Tool offset and incremental measurement function 

799000169 / Rev. 0 / 2019-06-07 

Translation of the original operating manual 

Summary of Contents for HWD15 Series

Page 1: ...ring principle LCD display with signs special characters and battery status indicator Symbol for angular measurement assignable Fraction display in inch mode possible Resolution 0 1 mm or 0 01 mm via parameters Display inch mode 0 001 Inch is possible Tool offset and incremental measurement function 799000169 Rev 0 2019 06 07 Translation of the original operating manual ...

Page 2: ...z Str 1 D 78239 Rielasingen Worblingen Technical Support 49 0 7731 9339 0 49 0 7731 2 88 03 info elgo de Document No 799000169 Document Name HWD15 000 MA E_23 19 Document Revision Rev 0 Issue Date 2019 06 07 Copyright 2019 ELGO Electronic GmbH Co KG ...

Page 3: ...n of Transport 6 2 12 Storage 6 3 Product Features 7 3 1 Application Examples 7 4 Technical Data 8 4 1 Identification 8 4 2 Dimensions 8 4 3 Technical Data 8 5 Power Supply Battery Change 9 6 Installation and First Start Up 10 6 1 Operating Area 10 6 2 Mounting on the Shaft 11 6 3 Adaptation to the Spindle Pitch 11 6 4 Display Overview 12 6 5 Key Overview 13 6 6 Parameter Level 14 6 7 Parameter Li...

Page 4: ...anger indicates an immediate danger for the life and health of persons Failure to heed these instructions can result in serious damage to health and even fatal injury WARNING This symbol in connection with the word Warning means a possibly impending danger for the life and health of persons Failure to heed these instructions can result in serious damage to health and even fatal injury CAUTION This...

Page 5: ...ompany is obliged to take appropriate safety measure The initial operation may only be performed by qualified and trained staff Selection and installation of the devices as well as their embedding into the controlling system require qualified knowledge of the applicable laws and normative requirements on the part of the machine manufacturer 2 6 General Causes of Risk This chapter gives an overview...

Page 6: ...ons for Transport Unpacking and Loading CAUTION Transport the package box palette etc professionally Do not throw hit or fold it 2 10 Handling of Packaging Material Notes for proper disposal 2 5 2 11 Inspection of Transport Check the delivery immediately after the receipt for completeness and transport damage In case of externally recognizable transport damages Do not accept the delivery or only a...

Page 7: ...splay can easily be adapted to the respective spindle pitch see 6 3 The device provides a common baby cell good quality So the system operates within 12 months of continuous operation NOTE In the power off mode the movements or adjustments of the magnetic sensor are not covered A referencing has to be performed after the start of operation at a required mechanical posi tion the indicator must be s...

Page 8: ...ctive 12 o clock Keyboard foil with short stroke keys Measurement principle quasi absolute Measurement type rotative Battery supply 1 5 V baby cell Type C LR14 Current consumption 1 mA at 1 5 V Batter service life approx 12 months depending on battery type Resolution encoder 1250 ppr indicator 0 01 mm basic resolution Operation speed max 2 5 m s Rotation speed max 1500 rpm Housing dimensions B x W...

Page 9: ...efer to the markings on the battery case When the battery is changed all data and parameters are retained apart from the current actual value The included quality battery enables the HWD15 to operate continuously for up to 12 months The status of the battery is shown on the LCD display On the front side below the hollow shaft there is the battery case which can be opened without tools by gently pr...

Page 10: ... not be installed close to sources of strong inductive or capacitive interference or strong electrostatic fields CAUTION The electrical connections must be made by suitably qualified personnel in accordance with local regulations The device may be designed for switchboard mounting During work on the switchboard all components must be de energized if there is a danger of touching the energized part...

Page 11: ... 2 Fix the HWD15 on the shaft by tightening the two grub screws B with 2 mm hexagon socket which are attached to the side of the hollow shaft body C 3 Finally fix the two M4 studs bolts A with corresponding nuts 6 3 Adaptation to the Spindle Pitch Calculate the correct pulse multiplication factor for the HWD15 according to the spindle pitch as follows Enter the calculated factor in parameter P08 s...

Page 12: ... 1 3 4 Battery status icons 3 elements Supplementary information For different applications the symbol for the measurement unit can be changed via parameter P02 e g the degree symbol for angle measurements see section 6 7 The normalization of the display value must be carried out manually using the multiplication factor P08 and the decimal place P03 see section 6 7 In the Inch mode an additional f...

Page 13: ... in the Operator Level see 6 9 Function in the Parameter Level see 6 6 Base key for keyboard combination Activate deactivate parameter level Fraction display in the Inch mode Select next digit decades Activate deactivate Incremental Measurement Increase value by 1 Activate deactivate Tool offsets Change of directional sign Key Function in the Initialization Level see 6 8 If the device is activated...

Page 14: ...rs are selected one after the other 6 6 2 Decade Selection Press key once Press this key to move the decade one digit from left to right The selected changeable decade flashes on the display 6 6 3 Change Value Press key once With this key the value in the selected decade is always increased by 1 0 9 or 0 1 6 6 4 Change Sign With this key the sign can be changed for some parameters negative sign is...

Page 15: ...l place 0 4 only for mm mode 2 P05 ABC Key lock A Set key 0 enabled 1 disabled B Incr Abs key 0 enabled 1 disabled C key 0 enabled 1 disabled 000 P07 A Basic resolution only firmware V1 50 and higher A 0 resolution 0 01mm A 1 resolution 0 1mm 0 P08 Pulse multiplication factor 0 0001 9 9999 1 0000 P09 Reference value 9999999 9999999 0 P10 Offset 1 9999999 9999999 0 P11 Offset 2 9999999 9999999 0 P1...

Page 16: ...After finishing the calibration the device will start automatically in the operator level 6 8 2 Load the Default Parameters and simultaneous Calibration REMARK Parameters that have already been changed are overwritten by the default parameters Therefore make a note of your individual settings before loading the defaults Switch off the device remove battery Keep pressing the key While pressing the ...

Page 17: ...ppears in the display Actuating the key again the absolute is activated and the symbol ABS is displayed 6 9 4 Offset Measurement Activation Press key once This key enables disables each of the three adjustable offset dimensions only possible in the absolute mode In each case an offset is added to the display value The activation of an offset level is indicated by the symbols 1 2 or 3 The offset me...

Page 18: ...ed as follows 1 Installation of RC circuits via contactor coils of AC contactors e g 0 1 µF 100 Ω 2 Installation of recovery diodes via DC inductors 3 Installation of RC circuits via the different motor phases in the terminal box of the motor 4 Do not connect protective earth and ground 5 Connect a mains filter ahead of the external power pack 7 2 Re start after Fault Clearance After the fault cle...

Page 19: ...8 Type Designation Series Type Rotative encoder with display battery Version 000 standard version 001 first special version etc Power Supply 001 1 5 V baby cell Type C LR14 integrated battery case with cover HWD15 000 001 ...

Page 20: ... 20 Notes ...

Page 21: ... 21 Notes ...

Page 22: ... 22 Notes ...

Page 23: ... or Absolute Measurement 17 Initialization Level 16 Installation 10 Key Overview 13 Maintenance 18 Mounting on the Shaft 11 Offset Measurement 17 Operating area 10 Operational safety 4 Operator Level 16 Order reference 8 Packaging material 6 Parameter Level 14 Parameter List 15 Power Supply Battery Change 9 Product Features 7 Protection against contact 10 Protective equipment 5 Reference Value Dir...

Page 24: ...e HWD15 000 MA E_23 19 Subject to change 2019 ELGO Electronic GmbH Co KG ELGO Electronic GmbH Co KG Measuring Positioning Control Carl Benz Str 1 D 78239 Rielasingen Fon 49 0 7731 9339 0 Fax 49 0 7731 28803 Internet www elgo de Mail info elgo de ...

Reviews: