background image

 

 

 

 

 

 

 

 

 

LogMaster-800

 

8-Channel Stand Alone Voice Logger

 

 

 

User’s Manual

 

First Edition 

 
 
 
 

C

2018 Eletech Enterprise Co., Ltd 

All Rights Reserved

 

Summary of Contents for LogMaster-800

Page 1: ...LogMaster 800 8 Channel Stand Alone Voice Logger User s Manual First Edition C 2018 Eletech Enterprise Co Ltd All Rights Reserved ...

Page 2: ...Master 800 User s Manual 1 TABLE OF CONTENTS Introduction 2 Package Contents 3 Panel Descriptions 4 Typical Connection 5 Touch Panel 6 Web Access 12 Telephone Access Flowchart 23 System Specifications 124 ...

Page 3: ...aster 800 can be searched and reviewed from a remote PC via the network using just a web browser such as Internet Explorer Chrome or Firefox System configuration and management are also done in the same manner requiring no proprietary software In addition to web based remote access the record data can also be accessed via the built in LCD touch screen This feature makes the logger ideal for locati...

Page 4: ...CRIPTION 1 LOGMASTER 800 8 RJ 11 Telephone Cord 4 RJ 11 Y splitter Connector 1 RJ 45 Network Cable 1 Power Adapter 1 External Start Manual Start Cable 1 Installation CD If any item is missing or broken upon opening of the package please contact your dealer immediately ...

Page 5: ...ady Orange Flashing Off Network Activity No Network Activity Orange Flashing Off Writing Data Not Writing Data Green Solid Off Phone Access In Use Phone Access Not In Use L1 L8 Red Solid Off Channel Recording Channel Not Recording Volume Volume dial for the internal speaker Earphone 1 8 mono phone jack for private listening USB Record data can be selectively saved to a USB drive connected to this ...

Page 6: ...onnections for two analog phone lines or other analog audio sources Use the included Y splitter to connect the lines EXT START Connection for an optional external trigger button SMDR Reserved for future use TEL Connection for an optional analog line used for phone access DC 5V Connection for the power adaptor 4 Typical Connection ...

Page 7: ...tem automatically moves to the menu one layer up Main Menu About Get system information such as device name IP address firmware version system status and time Use the Status button to display channels status Long Idle The channel has not recorded anything for longer than the Long Idle time default 1440 minutes OK The channel is working properly Disconnect No phone line is connected to this channel...

Page 8: ...h Local Phone VOX and Manual Alarm Set the Long Idle time and the Long Recording time Long Idle When a channel has not recorded anything for longer than this setting its icon on the main menu will turn red indicating potential hardware issues Long Recording When a channel has made recording s longer than this setting its icon on the main menu will turn red indicating potential hardware issues ...

Page 9: ...ddress Subnet Mask Gateway and DNS server Password The default password for the Settings menu is 999 If a new password is set and later lost use the reset button to restore the default password Reboot Reboot the system Shutdown Shut down the system ...

Page 10: ...LogMaster 800 User s Manual 9 Date Time Set system clock NTP server IP and synchronization interval Close Quit and return to the Main menu ...

Page 11: ...to monitor the call in real time Only one channel can be monitored at one time Search Select the target channel and enter the search date time Tap OK to retrieve the search result The logger will search and play the file closest to the search date time Save Save the file to an external USB drive Loop Loop play the file Prev Move to the previous file Next Move to the next file ...

Page 12: ... User s Manual 11 Password The default password for the Monitor Search menu is 123 If a new password is set and later lost use the reset button to restore the default password Close Quit and return to the Main menu ...

Page 13: ...b Access Device Login Open the web browser and go to the logger s IP address e g http 192 168 1 100 Enter the user name default admin and the password default 123 Then click the Login button A screen similar to the following will appear ...

Page 14: ... enter the Record Data Search window Channel Select the target channel or choose All to search all channels Time Period Select today last 3 7 30 days or specify a time period Click Search to start searching Click the speaker icon to play the corresponding record ...

Page 15: ...rd one time then stop Repeat Play the target record repeatedly Play All Time Backward Play the entire list from the last file to the first file Play All Time Forward Play the entire list from the first file to the last file Download Click to download this record ...

Page 16: ...LogMaster 800 User s Manual 15 Device Monitoring Click it to enter the Device Monitoring window The window shows storage NTP synchronization and line status System errors are listed in the error log ...

Page 17: ...tiple records The default value is 1800 seconds 30 minutes and the maximum value is 3600 seconds one hour Record Gain This adjustment helps to boost weak signals on the line A higher value means a stronger boost You can also select AGC and let the system automatically adjust the gain for each call AGC Check the box to enable AGC Automatic Gain Control which is default and recommended When the AGC ...

Page 18: ... is too short phone calls are more likely to be broken into two or more records If the Stop Delay is too long consecutive phone calls are more likely to be saved as one record if they occur within short intervals Typically a value between 3000 to 5000 milliseconds works the best Voltage Threshold This setting applies only when the Local Phone record mode is enabled When the line voltage drops belo...

Page 19: ...ce Settings window Keep Records For Days This function is currently not implemented Recycle When Less Than Storage recycling starts when the free space drops below this threshold level The system deletes the oldest records in order to make room for new records Default is 20 ...

Page 20: ...nc interval and time zone The logger will automatically synchronize its time with the NTP server Alert Settings Line Idle Alert Time When a channel has not recorded anything for longer than this setting the logger will generate a warning indicating potential hardware issues Long Recording Alert Time When a channel keeps recording for longer than this setting the logger will generate a warning indi...

Page 21: ...agement For changing the password Click it to enter the Account Management window Changing the password from default is highly recommended If the new password should be lost use the device s hardware reset button to restore the default password ...

Page 22: ...For firmware update Click Choose File and select the target firmware bin file on your local hard disk Enter Super User Password 999 this password can be changed via the logger then click Start Upgrade A window similar to the following will appear ...

Page 23: ...LogMaster 800 User s Manual 22 Select English Language for English version Click Device Reboot to confirm the firmware upgrade The upgrade will be done in about 1 minute ...

Page 24: ... press 1 for channel 1 Then press the key to confirm or the key to cancel The following recording is found plays date time length of the recording Please enter the date and time Then press the key to confirm or the key to cancel Hang up To play the recording press 7 To stop playing press 9 To cancel press To play the previous recording press 4 To play the next recording press 6 The entry is invali...

Page 25: ...l 40 dbm to 9 dbm AGC 40 dB S N Ratio 45 dB Caller ID DTMF FSK Record Mode Loop Voltage Voice VOX and manual control Recording Time 4160 hours 32GB SDHC card USB Up to 64GB for data exporting LCD Touch screen 5 TFT Resolution 480 272 Warnings Screen Display line disconnect idle too long and record too long Live Monitoring On device only one channel at a time Search Play On device via telephone lin...

Reviews: