background image

H.R.UV-C

Installation & Operating Manual

HR-55

HRP-55 

HR-110
HRP

-1

1

0

Summary of Contents for HR-110

Page 1: ...H R UV C Installation Operating Manual HR 55 HRP 55 HR 110 HRP 110...

Page 2: ...y and turn off the water supply before carrying out maintenance Always disconnect all pool appliances from the mains electricity supply before servicing Power must be supplied through a Residual Curre...

Page 3: ...ailable in 55W single tube and 110W double tube formats supplied complete with flow switch and either an analogue lamp life indicator and reset switch or digital lamp life countdown with intelligent d...

Page 4: ...www elecro co uk 1 ENGLISH Fig 2 110W Double Tube Unit 3 Note Digital Model Shown...

Page 5: ...mounted on a flat vertical surface horizontally or vertically It must not be submerged in water or placed in a position where water may collect around the unit To prevent the unit inadvertently being...

Page 6: ...own in the next pages in fig 5 and 6 or horizontally as shown in fig 7 NOTE When mounting the UV it is essential to leave a clearance space of at least 1 metre from one side of the unit to allow acces...

Page 7: ...2 www elecro co uk ENGLISH Washer x4 Screw x4 Raw plug x5 Fig 5 6 55W Single Tube Unit...

Page 8: ...www elecro co uk 2 Fig 6 7 110W Double Tube Unit Washer x5 Raw plug x5 Screw x5...

Page 9: ...ntal mounting 55W Single Tube Unit Horizontal mounting Water must enter low and exit high Water must enter low and exit high Factory Default Optional reverse flow explained on page 10 Factory Default...

Page 10: ...For connection to 63 mm or 2 diameter pipe Insert 63 mm diameter pipe up to this stop Insert 2 diameter pipe up to this stop A D H E S I V E ABS PVC Insert 50 mm diameter pipe up to this stop Insert 1...

Page 11: ...is lifted by more than 5mm from its housing and turned with force If the flow switch has been rotated it is important to ensure that it is finally locked in the correct orientation perpendicular at ri...

Page 12: ...fter this set period of time At initial Power On of the H R UV C the LED indicator will light in Red colour for one second to indicate that the time setting is 9 000 hours and immediately change colou...

Page 13: ...2 www elecro co uk ENGLISH 12 Fig 9 LAMP LIFE INDICATOR RESET SWITCH...

Page 14: ...suction tube to the dosing pump This is how the completed assembly will look STEP ONE Components required Tubing Foot Valve Strainer STEP TWO Unscrew securing cap anti clockwise Lamp Life Indicator I...

Page 15: ...3 STEP FOUR Once all components are looped through the tubing tighten securing cap STEP FIVE Lastly unscrew the retaining gland and insert tube over the connection point Tighten the retaining gland Pl...

Page 16: ...the unit The factory default setting for the language is English To change to another language press the buttons until the de sired language appears press OK to select and save Fig 12 Fig 11 DIGITAL D...

Page 17: ...e unit is receiving sufficient flow See page 10 for flow requirements UV Lamp Life www elecro co uk The digital controller has four programmable functions UV Lamp Life Shock Dose Dose Chemical Set Tim...

Page 18: ...button to confirm the display will then show H2O2 START You now need to enter the time that you would like the dosing to take place NOTE the time must be entered in the 24 Hour format and the dosing w...

Page 19: ...volume see page 26 27 at the rear of this manual NOTE The above table is based on dosing Hydrogen Peroxide H O with a 32 concentration and a water temperature of 28 C For a concentration of 12 the abo...

Page 20: ...hen show CL 2 DOSE you now need to repeat the above process to programme the CL 2 DOSE volume and CL 2 START time NOTE the time must be entered in the 24 Hour format and the dosing will take place at...

Page 21: ...our format The display will now revert to showing the UV lamp life remaining and the current time Shock Dose The shock dose feature enables the operator to shock dose the pool immediately with a chose...

Page 22: ...guide you how to replace the dosing tube STEP ONE Unscrew the two screws securing the plastic cover and remove Rotate the grey connection caps to release the tubing STEP TWO Remove the connection poin...

Page 23: ...Once securely in place cut the excess tie and dispose of STEP FIVE Place dosing tube into position on the left hand side Carefully rotate the cam clockwise whilst feeding the pipe back into place STEP...

Page 24: ...blue lamp holder shroud then pull the white plastic electrical end caps from the lamp end Gently slide the lamp out ensuing that no pressure is applied to the glass quartz sleeve Next unscrew the two...

Page 25: ...it to release any trapped air Failure to release the trapped air may cause the lamp holder to disconnect from the lamp end Reconnect and turn on the water supply to check for leaks before reconnecting...

Page 26: ...ntial negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product The recycling of materials will help to conserve natura...

Page 27: ...as a sloping bottom then take the deepest measurement D2 and the shallowest D1 If there are different levels then you need to do several calculations of area for each depth and add them up at the end...

Page 28: ...graph paper using a square on the paper to represent a metre or foot square of pool When you have finished count the squares For partial squares count anything over half as one and ignore any under a...

Page 29: ...bic Metres to Litres Multiply by 1000 Cubic Feet to Cubic Metres Multiply by 0 0283168 UK Gallons to Litres Multiply by 4 54609 Litres to Cubic Metres Multiply by 0 001 Cubic Metres to UK Gallons Mult...

Page 30: ......

Page 31: ......

Page 32: ...11 Gunnels Wood Park Stevenage Hertfordshire SG1 2BH United Kingdom t 44 0 1438 749 474 f 44 0 1438 361 329 e sales elecro co uk www elecro co uk Copyright 2017...

Reviews: