1

Summary of Contents for ATC-700

Page 1: ...1 ...

Page 2: ...Column Oven ATC 700 User s Manual ATC700MAN_0802 2008 Eicom Corporation All rights reserved ...

Page 3: ...ecifications 3 3 Setup 3 3 1 Parts List 3 3 2 Installation 4 3 3 Parts Names 5 3 4 Power 6 4 Operation 6 4 1 Display Panel 6 4 2 Operations Keys 6 4 3 Display 7 4 4 Main Power ON OFF 7 4 5 Operation 8 5 Error Messages 10 6 Ventilation Duct 10 Limited Warranty 11 ...

Page 4: ...le phase and the electrochemical detector cell Safety Precautions Operation of the ATC 700 should only be performed by personnel trained in laboratory work and who are aware of the possible dangers involved in chemical reagents and other possibilities Read this manual carefully and in full All safety and operating instructions should be read prior to operation In this User s Manual the items that ...

Page 5: ...s includes any liquid that may leak from loose tube fittings If any solution comes into contact with the mechanical or electric parts the ATC 700 will be damaged possibly beyond repair 2 Use of Hazardous Material When using the ATC 700 the use of hazardous materials such as chemical reagents is necessary If you do not handle these materials appropriately it may result in your death or serious inju...

Page 6: ...25 cm Column Clips 2 pcs Dimensions 400W x 400D x 145H mm Weight approx 10 kg Power Supply AC100 240V 50 60Hz 210W 3 Setup 3 1 A list of the parts in the package When you open the box please confirm if the package contains the following accessory parts List of Accessory Parts includedin the ATC 700 package Item Code Qty Remarks User s Manual 1 Main Product ATC 700 1 Ventilation Duct 1 ECD 700 Powe...

Page 7: ...bench top in an indoor laboratory which meets the following requirements 1 The room temperature during the operation needs to be in the range of 15 30C 2 No high humidity environments where condensation may form on the equipment 3 Not exposed to direct sunlight 4 Away from air conditioning or heating vents 5 No vibration 6 Clean environment with a minimum of dust 7 Not near any other device that c...

Page 8: ...splay Vent for fan and Peltier device Main Door Grounded Column Clips Main Power Switch Back View Main Power Receptacle Fuses Ground Terminal Cooling Fan Auxillary Door Open Door Sensor Inlet Outlet Tubing Ports Right Side View Front View Left Side View ...

Page 9: ... Power Voltage AC 100V 240V 10V Frequency 50 60 Hz Consumption 210 W 4 Operation 4 1 Display Panel Display Panel 4 2 Operation Keys Key Name Function Set Enter the setting temperature Arrows Choosing setting temperature 6 Temperature Display Increase Decrease Buttons ...

Page 10: ...et point temperature 4 4 Main Power ON OFF The main power ON OFF is located on the left side as you face the instrument After the initial display the display will show the status Initial Display Status Display Set Point temperature is stored 7 Current Temp Set Point Temp ...

Page 11: ...n power on Status Display appears after initialization To set the temperature up hit key To set the temperature down hit key At the ST Mark will appear When the required temperature is shown at ST hit SET Key PT will match ST when the new temperature is reached ...

Page 12: ...Turn of the main power and wait 15 sec Then turn on again If the error persists please contact us ERROR 3 with beep Peltier Unit Error Turn of the main power and wait 15 sec Then turn on again If the error persists please contact us 6 Ventilation Duct This ventilation duct comes with the ATC 700 and can be installed according you your needs If you need to attach the duct by yourself please contact...

Page 13: ...ns and warnings relating to product s use 2 Repair or alteration by anyone other than Eicom 3 Damage during shipping or transit or any other accidental damage 4 Damage due to use with hazardous voltages 5 Damage due to improper connection of equipment 6 Damage due to any act of God 7 Any other inappropriate usage of parts or consumables that is not authorized by Eicom All rights reserved Use of im...