background image

EiA200 Series

Z-Wave CO Alarms 

CARBO

N

MONOXIDE

ALARM

ALARM

FAULT

POWER

Quick Start

This device is a Z-Wave sensor reporting Carbon Monoxide Danger. Pressing the ‘Inclusion Button’ for one second adds (includes) and removes 

(excludes) the device from/to the Z-Wave network.
Please refer to the chapters below for detailed information about all aspects of the product.

Model & Description:

Alarm Model

Description

EiA207RFZ

Z-Wave Carbon Monoxide Alarm

EiA207DRFZ

Z-Wave Carbon Monoxide Alarm with Display

Product description

This product combines a certified Carbon Monoxide Alarm with a plug-in Z-Wave module to form a wirelessly reporting Carbon Monoxide Alarm. This 

enables the Alarm to be wirelessly linked to a third party controller. When any of the linked products are triggered by Carbon Monoxide the Alarm 

will transmit a message to the Main controller. The Carbon Monoxide Alarm is certified to UL2034 single or multiple station Carbon Monoxide Alarm 

is also Z-Wave alliance and FCC certified.
This premium quality Carbon Monoxide Alarm is equipped with a large test button, which is conveniently accessible even when mounted on the ceiling. 

Three colored LEDs on the device indicate Alarm, Fault and Power indicator.
The device is a secure Z-Wave Plus device and can be used in a wireless Z-Wave network. It supports secure communication only when the central 

controller also supports secure communication. Even if included securely the device is able to communicate unsecured with devices included unsecure 

using the association groups 2 and 3. 

Quick Installation Guidelines

Please refer to the installation guide of the Carbon Monoxide Alarm for information about how and where the Carbon Monoxide Alarm should be 

installed. Please note that the Carbon Monoxide Alarm will also work stand-alone even if the Z-Wave network is not present.
•  The first step is to insert the 2x AAA batteries provided (see Figure 1), then fix the mounting base in the desired location as per the installation guide 

for Carbon Monoxide Alarms.

• Include the Sensor into your existing Z-Wave based Smart Home Network using the ‘Inclusion button’ (see Figure 2). The green LED will blink briefly.
• Place the Alarm on the mounting base and turn clockwise. Now the Alarm is armed.

Battery Replacement

See EiA200 Series Installation guide for battery replacement instructions.

Inclusion

Button

Antenna

LED