background image

USER GUIDE 

Your ECOGATE System works fully 
automatically. After initially powering up 
the greenBOX, it will open blast gate #1 
and sequentially close all other blast gates.  

HOW AUTOMATIC MODE 

WORKS? 

If you switch any workstation ON, the 
greenBOX will open the appropriate blast 
gate and switch the dust collector ON. 
Turning workstations OFF will similarly 
close the appropriate gates. One gate (the 
last gate used) will remain open, however, 
to ensure trouble-free vacuum operation. 
Upon turning OFF the last operating 
workstation, the greenBOX will switch the 
dust collector OFF as well. 

FRONT PANEL INDICATORS 

If any blast gates (1-8) are open, then the 
corresponding indicator (1-8) will be ON 
to reflect this status. During blast gate 
movement the corresponding LED indica-
tor flashes. 

Whether the dust collector is ON or OFF 
is indicated by the LED marked “Dust 
collector”. The LED marked “Power” in-
dicates that a power supply is present. 

USING THE “REMOTE 

CONTROL” ROCKER SWITCH 

This switch operates blast gate #8 and op-
erates the dust collector in conjunction 
with a floor sweep or hand-held tools. 

MANUAL MODE 

Press the “AUTO-MANUAL” button to 
enter the greenBOX into the MANUAL 
mode. The “Manual ON” red LED indi-
cator will start flashing. In the manual 
mode the dust collector is permanently 
ON. 

In manual mode you can control all con-
nected blast gates via the corresponding 
buttons marked “1-8”. The first press of 
the button will open the blast gate. The 
second press of the same button will close 
the blast gate. 

 

VOLTAGE SELECTOR & FUSE 

Under the front cover (at the top of the 
box on the bottom printed board, under 
the power terminals) there is a voltage se-
lector. On this selector there is a small 
window where the selected voltage (115 or 
230V) is visible. To select the voltage, use a 
small flat screwdriver and move the switch 
so that you see the desired voltage in the 
small window. 

You must also change the fuse – the cor-
rect value for 115V is 

T0.250 A 

(

5 x 20 

mm), and for 230V the correct value is 

T0.125

 

A

. Both fuses are delivered with 

the unit. 

ECOGATE, INC. 

1821 Tyburn St., Glendale, CA 91204, 

Tel: 818-547-4007, Fax: 818-547-4005 

Email [email protected] 

www.ecogate.com 

© ECOGATE, INC.  1999-2003 

FULLY AUTOMATIC DUST 

COLLECTING SYSTEMS 

 

Short Form User And 
Installation Guide, Version 4 

 

 

 

Please read 

User and Installation Guide 

before 

ECOGATE System installation and operating. You 

are individually responsible for adhering to all safety 
regulations and codes (National Electric Code).

Reviews: