Page 1: ...v 20190509 PAGENETDN DIGITAL CONTROL EclerNet Dante Paging Station Control Touch Screen USER MANUAL ...

Page 2: ...lation and wiring 7 5 2 Audio Settings 8 6 OPERATION 9 7 LOCAL CONFIGURATION OF THE UNIT 11 7 1 Screen Configuration menu 12 7 2 Device Configuration menu 14 7 3 Network Configuration menu 15 7 4 Information Tools menu 16 8 CONNECTION TO A UCP SERVER 18 9 PACKAGE CONTENTS 20 10 FUNCTION LIST 20 11 FUNCTION DIAGRAM 21 12 BLOCKS DIAGRAM 22 13 TECHNICAL FEATURES 23 ...

Page 3: ...rked with symbol of may be of sufficient magnitude to constitute a risk of electric shock The external wiring connected to the terminals requires installation by an instructed person or the use of ready made leads or cords WARNING To prevent fire or shock hazard do not expose this equipment to rain or moisture WARNING An apparatus with Class I construction shall be connected to a mains socket outl...

Page 4: ... any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 14 Disconnecting from mains switching off the POWER switch all the functions and light indicators of the amplifier will be stopped but fully disconnecting the device from mains is don...

Page 5: ...rix no matter whether it supports Dante or not MIO4040DN MIMO88 MIMO88SG and MIMO1212SG At the same time it shares the same control features as the WPNETTOUCH and can be programmed to control one or more networked EclerNet devices it can even control a full installation a project combining a multitude of different EclerNet devices MIMO4040DN MIMO88 MIMO88SG MIMO1212SG digital matrices NXA series d...

Page 6: ...on o Dante channel 2 used for AUX input signal transmission Phantom Power available for the MIC input MIC out analogue balanced signal that makes the PAGENETDN unit compatible for paging in combination with devices that don t support Dante in a native way as the MIMO88 MIMO88SG and MIMO1212SG AUX input stereo LINE RCA connectors The incoming signal is converted to mono and sent to the network usin...

Page 7: ...ilable from the Ethernet switch the unit is connected to or by means of the included external Power Supply 12 VDC 2A EXTERNAL PSU CONNECTOR Additionally there are 2 extra audio connectors available AUX IN L R stereo LINE input RCA connectors The incoming signal is converted to mono and sent to the network using Dante channel 2 This input can be used to connect an external audio source like a media...

Page 8: ...00Hz 12dB oct applied to the audio signal captured from the microphone capsule to minimize low frequency and unwanted noise entering into the voice messages path along the audio system MIC IN GAIN preamp gain adjustment for the incoming microphone signal It affects both the resulting Dante ch 1 output and the ANALOGUE AUDIO MIC OUT signal AUX IN GAIN LINE GAIN preamp gain adjustment for the incomi...

Page 9: ...ENET must be properly included in an EclerNet project and configured regarding Dante audio routing and or control features to finally show the UCP paging and control panels that the end user will have available Examples ...

Page 10: ...10 Please refer to EclerNet Manager application user manual chapter PAGENETDN DEVICE for further information ...

Page 11: ...nes available for the WPNETTOUCH device as it really includes a WPNETTOUCH unit in it The same settings are remotely accessible when the unit is under the control of a remote computer running the EclerNet Manager application Local access to the configuration menus can be done by clicking on the SETUP icon from the home page of the unit The available configuration menus are the following ...

Page 12: ...fter 10 seconds of user inactivity on the touch screen The available modes are ON always lit DIMMED and OFF unlit Backlight Intensity brightness intensity of the screen when it is not in sleep mode Auto Zoom Panels when activated the graphic control panels UCPs are automatically resized to match the maximum visible area no matter the original resolution they were created in the EclerNet Manager pr...

Page 13: ...t for the layout of the controls buttons sliders knobs etc on each UCP page during its design the corners must be as free as possible if these OSD buttons will be used for scrolling between pages top ones and always free in the case of the bottom ones icon bar display Scroll by OSD Buttons enables disables the scroll action between pages pressing the top corners even the OSD buttons are hidden Scr...

Page 14: ...lly functional taking control of the hardware devices that are included in it MIMO4040DN MIMO88 NXA units etc and serving the UCP panels it contains to potential UCP clients on the network o Disabled the EclerNet Local Project is deactivated releasing the control over all included hardware MIMO4040DN MIMO88 NXA units etc and consequently also ceasing to serve UCPs for clients Warning In the disabl...

Page 15: ...e the devices controlled by the unit by setting the Enable UCP Server option on NO 7 3 Network Configuration menu This menu allows modifying the network connection parameters of the WPNETTOUCH unit IP address network mask and gateway Note neither the WPNETTOUCH nor any other EclerNet device supports the protocol of dynamic allocation of IP addresses Dynamic Host Configuration Protocol or DHCP so i...

Page 16: ...ress IP Address configured for the WPNETTOUCH unit Local Project name of the project stored in the internal storage space of the WPNETTOUCH unit This project can be uploaded to the WPNETTOUCH unit using EclerNet Manager software app Available Storage internal storage space available to upload a project file which would include User Control Panels data and graphics Ethernet Address MAC address of t...

Page 17: ...ect in memory replacing it with a blank project after warning that the process is irreversible Factory Defaults clears the entire configuration and all data in the unit restoring the factory default settings after warning that the process is irreversible Reboot reboots the unit ...

Page 18: ... the UCP server the unit will connect to as a client The UCP server may be a computer a MIMO4040DN matrix yes it has an embedded UCP server in its engine another WPNETTOUCH WPmSCREEN unit or even the same PAGENETDN WPNETTOUCH unit In any case the UCP server shall host and run an EclerNet Manager project that includes a series of UCPs which can be remotely managed by any UCP client ...

Page 19: ...the Connect button Note in the list of detected server devices the name of the WPNETTOUCH unit under control will appear in green the one matching with the Local IP Address After selecting a server unit or an IP address using either of these two methods pressing the Connect button will confirm the selection and start the process of connecting to the server If this process is successful the UCPs th...

Page 20: ...ooseneck microphone anti pop screen External PSU 24V 12A universal multi AC plug Euroblock 3p aerial connector Quick User Guide and Warranty Card 10 FUNCTION LIST 1 Multi touch screen 2 Gooseneck Microphone 3 XLR connector 4 Power cord hole ...

Page 21: ...21 11 FUNCTION DIAGRAM ...

Page 22: ...22 12 BLOCKS DIAGRAM ...

Page 23: ...e Network Tx channels Latency Connector 2 1 2 5 ms selectable RJ45 AUDIO OUTPUTS Microphone output signal Connector Output level Balanced analog Phoenix connector symmetric 0dBV System CPU RK3128 quad core processor clocked 1 6G RAM 1GB ROM 8GB Screen Size 10 1 IPS Resolution 1280x800 Contrast ratio 1300 Brightness 300cdm2 Screen scale Display area 16 9 218x135mm Backlight LED Touch panel Capaciti...

Page 24: ...24 Dimensions microphone excluded TBD Weight TBD AC Power Adapter 90 264VAC 47 63Hz 12V 2A Accessories included AC power adapter 90 264VAC 47 63Hz 12V 2A multi plug Microphone Ecler eMCN1 ...

Page 25: ...e to production tolerances NEEC AUDIO BARCELONA S L reserves the right to make changes or improvements in design or manufacture that may affect these product specifications Motors 166 168 08038 Barcelona España 34 932238403 information ecler com www ecler com ...

Reviews: