background image

 

 

 

 

 

 

 

 
 

 
 

 

                  VLCD-5 

VLCD-5 Display Instrument   

  Operation Manual 

 

 

 

 
 
 
 
 
 

 

Summary of Contents for VLCD-5

Page 1: ...VLCD 5 VLCD 5 Display Instrument Operation Manual...

Page 2: ...1 Specification 1 Installation 2 Function Description 3 Operation Flow 4 5 1 Button Definition 4 5 2 Operation and setting 4 5 3 Accessorial function 5 5 4 Hiding function and show 6 5 5 Failure code...

Page 3: ...peed of electric bicycle record the trip distance Specification Type VLCD 5 Working voltage DC 11V 60V Max working current 70mA 11V 32mA 50V Display type 21 4 21 4 segment LCD sampling 1 12 1 12 pulse...

Page 4: ...h male and operate on the 4 pin plug female On the plug 1 Orange RX 2 Brown TX 3 White Weak current 4 Green Power 5 Black Earth 6 Purple Brake VLCD wire system VLCD 5 controller 4 core push male Mater...

Page 5: ...4 9 Select wheel diameter Select wheel diameter among14 32 inch default option is 26 inch 4 10 Magnetic Steel number Select the magnetic steel number of the speed sensor default value is 1 4 11 Speed...

Page 6: ...minutes 2 OFF ECO TOUR SPEED TURBO 5 ECO There are 4 levels of power assist none low medium high Press this button to adjust the power assist from low to high Default is medium assist ECO TOUR SPEED T...

Page 7: ...dograph ODO Under the condition of in odometer press the three buttons at the same time for 2s and the odograph reset Odometer Trip distance TRIP In the trip distance state press the button 2s Reset c...

Page 8: ...n startup screen then all the items including normal functions and special functions shows up Then wait for about a second until the screen changes Then go quickly through the modes menue steps There...

Page 9: ...The number represents one turn of the wheel the pulse signal output Magnetic steel number selection Speed units selection km h mil h Use the button to enter the speed units interface press button to s...

Page 10: ...admustment selectin not available yet Use the button to enter the power adjustment selection press or buttons to switch between 6 35 Default is 25 This function not available reserved for next version...

Page 11: ...ition the diagnosis codes will be displayed The fault detection will be launched automatically when rotating the handle and it will stop when the handle is reset ERR 02 Motor hall fault or motor short...

Reviews: