background image

INS #

ADX142857  

049-255

Sure-Lites

Installation Instructions for the Sure-Lites SEL Emergency Lights 
without Remote Capacity

 WARNING 

Risk of Fire/Electric Shock

If not qualified, consult an electrician.

  WARNING 

Risk of Electric Shock

Disconnect power at fuse or circuit breaker before 

installing or servicing.

Important Safeguards

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY 
PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING 
THE FOLLOWING.

1. READ AND FOLLOW ALL SAFETY INSTRUCTIONS 

2. Do not use outdoors. 

3. Do not use in hazardous locations, or near gas or electric 

heaters. 

4. Do not let power supply cords touch hot surfaces. 

5. Use caution when servicing batteries. Battery acid can 

cause burns to skin and eyes. If acid is spilled on skin or in 
eyes, flush acid with fresh water and contact a physician 
immediately. 

6. Do not use this equipment for other than the intended use. 

7. Installation is to be performed only by qualified personnel. 

8. Install in accordance with National Electric Code and local 

regulatory agency requirements. 

9. The use of accessory equipment not recommended by the 

manufacturer may cause an unsafe condition. 

10. Equipment should be mounted in locations and at heights 

where it will not readily be subjected to tampering by 
unauthorized personnel. 

11. SAVE THESE INSTRUCTIONS

MAX MOUNTING HEIGHT:
17.24 FT for SEL25 models
25.39 FT for SEL50 models

INSTALLATION

1.  De-energize the circuit at the junction box (J-box) where 

the emergency light is to be installed. 

2.  Open the emergency light by inserting a screwdriver in the 

two slots at the bottom of the unit, then tipping the cover 
up off of the backplate.

3.  To mount to a junction box - Drill out the appropriate 

mounting pattern and the wire pass hole in the backplate 
to fit the J-box being used.

4.  To mount to conduit – Cut out the U shaped knockout on 

the cover using snips, then attach the 1/2” conduit hub to 
the backplate.

5.  Once the backplate is secured, the housing can be held in 

place during installation using the EZ Hang feature. (see 
Fig. 1)

6.  Connect the incoming wires to the fixture’s power supply 

wires using the wire nuts provided. Connect the white 
wire to neutral. If using 120V, connect the black wire to the 
hot lead. If using 277V, connect the orange wire to the hot 
lead.  Cap the unused lead. Secure the emergency light 
to the wall and/or junction box using installer supplied 
hardware. 

7.  Connect the battery to the PCB. See schematic for detail. 
8.  Snap the cover onto the backplate.
9.  Energize AC supply. The test button should illuminate, and 

LED heads will illuminate briefly when the test button is 
pushed.

10. Adjust the heads as needed.  
11. If the fixture is to be powered down for an extended 

period after initial installation, replace the EZ Key. This 
will prevent the battery from discharging when AC power 
is removed. However, it will also prevent the battery 
from charging when AC power is restored, so it must be 
removed once the unit is ready for regular operation.

Reviews: