background image

Earthquake Sound Corporation • 2727 McCone Avenue Hayward, CA 94545 • Ph: (510) 732-1000 Fax (510) 732-1095

www.earthquakesound.com

TremorX Installation

&

Reference Manual

TremorX

TremorX10-4/10-8
TremorX12-4/12-8
TremorX15-4/15-8

Summary of Contents for Thermo-rX-10-4

Page 1: ...ke Sound Corporation 2727 McCone Avenue Hayward CA 94545 Ph 510 732 1000 Fax 510 732 1095 www earthquakesound com TremorX Installation Reference Manual TremorX TremorX10 4 10 8 TremorX12 4 12 8 TremorX15 4 15 8 ...

Page 2: ... and development to provide you with the highest quality mobile audio products This owners manual is designed to better acquaint you with Earthquake products and to guide you through all phases of system design and application It is imperative that you read this manual in its entirety Earthquake technicians and staff are looking forward to answering any questions you might have TREMORX10 8 TREMORX...

Page 3: ...E 4 OHM coils the total load would be 1 3 ohm If using SINGLE 6 OHM coils the total load would be 2 ohm If using SINGLE 8 OHM coils the total load would be 2 7 ohm If using SINGLE 2 OHM coils the total load would be 0 5 ohm If using SINGLE 4 OHM coils the total load would be 1 0 ohm If using SINGLE 6 OHM coils the total load would be 1 5 ohm If using SINGLE 8 OHM coils the total load would be 2 oh...

Page 4: ...FER ENCLOSURE DESIGNS Dimensions shown are external Dimensions using 3 4 MDF 4 15 12 15 1 2 11 TremorX10 1Bass head design for competition 2 Port tuned design for deep bass 12 16 11 2 Port 4 diameter 8 1 2 long TremorX10 3 Sealed design for tight bass 12 12 11 1 4 TremorX 10 5 3 4 10 3 8 9 5 5 5 8 TremorX10 4 TremorX10 8 6 3 8 12 3 8 11 5 1 2 6 1 8 TremorX12 4 TremorX12 8 PORT 2 x12 5 x9 Internal ...

Page 5: ...s are subject to change without notice TREMORX ENCLOSURE DESIGNS EARTHQUAKE SOUND TREMORX SUBWOOFER ENCLOSURE DESIGNS Dimensions shown are external Dimensions using 3 4 MDF 5 1Bass head design for competition 2 Port tuned design for deep bass 3 Sealed design for tight bass TremorX15 4 8 TremorX15 4 8 6 1 2 15 13 3 4 6 3 8 7 TremorX15 4 TremorX15 8 PORT 6 x16 5 x16 5 Internal dimensions PORT 2 x16 ...

Page 6: ...technicians might be able to resolve the problem over the phone thus deemed to have no problem s will not be covered by the five 5 year limited eliminating the need to ship the product warranty Customer will be charged a minimum of one 1 hour of labor at the ongoing rates plus shipping charges back to customer F Shipping Instructions C Earthquake will repair or replace at our option all defective ...

Page 7: ..._____________________________________ __________________________________________________________ CITY _______________ STATE ____________ ZIP _______ PHONE ____ ____ ______ FAX ____ ____ ______ SIGNATURE _____________________ DATE ____________ YOUR COMMENTS _________________________________________ _________________________________________________________ ___________________________________________...

Page 8: ...ications without notice Copyright Earthquake Sound Corporation Earthquake Sound Corporation 2727 McCone Avenue Hayward CA 94545 Phone 510 732 1000 Fax 510 732 1095 Earthquake Sound Corporation 2727 McCone Ave Hayward CA 94545 www earthquakesound com From Postage Stamp ...

Reviews: