background image

            CREATED ON: August 23, 2021

 

 

 

Instruction Manual

 

 

 

H3CT-5U V2.0 

  

Preset Production Counter 

  

 

EAPL

 

 

 

     Introduction 

        H3CT- 5U

 

V2.0

 is an Up Counter with hold mode. 

        Apply rated voltage to source terminals and connect the sensor       
        input, display shows “00000” and starts counting the input pulses.  
        Once process value reaches set value 1C/O relay contacts   
        changes over to NO and remain in this state till the power is  
        interrupted or reset signal is applied.  
 
        

HOLD MODE:

 Continues counting after resumption of interrupted     

        Power. 
 
        

RESTART MODE:

 Counting starts from the beginning after the    

        Resumption of interrupted power.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Box Accessories

 

One (1) H3CT-5U V2.0 
One (1) Instruction Manual 

     

 
 
 
 

 
 
 
 
 

 

Function 

Up Counter with hold mode 

Rated supply Voltage 

85V to 270V AC/DC 

Rated frequency 

50/60Hz± 5% for AC only 

Power consumption                         

AC Approx. 8VA. 
DC Approx. 5W. 

Control Output                                 

RLY 1 - 1 C/ O 
Rated for 5A @ 250 VAC/ 30VDC(NO) 
3A @ 250VAC / 30VDC (NC) 

Display                             

5 digit 7 segment LED,0.30”

       

 

Count speed 

100Hz max.(min I/P pulse width 5msec) 

Range 

0 to 99,999 counts 

Resetting time 

250msec minimum 

Recovery Time                                

2 Sec minimum 

Ambient temperature                       

Operation : -10°C to +55°C 

Storage    : -25°C to +80°C 

Humidity 

MAX 95% RH @ 40ºC 

Service life (under no load) 

10

6

 operations minimum 

Electrical life (under full

 

load) 

 

10

5

 operations minimum 

Insulation resistance 

>100M ohm @ 500V DC 

 

Dielectric strength 

 
a) 2.5KV AC, 50Hz for 1 minute. 
(Between  current carrying& non-
current

 

carrying parts) 

b) 1.5KV AC, 50Hz for 1 minute.

                                                                      

(Between contacts & control circuit) 
c) 750V AC, 50Hz for 1 minute.

                                 

(Between non-continuous relay 
contacts)

 

Electrical connection 

Screw type terminals with self lifting 
clamps 

Dimension 

48 x 48 x 95.5mm (W x H x D) 

Sensor type                                              

Proximity NPN / PNP and Limit Switch. 

 

Technical Specification:

 

 

 
 
Safety Precautions

 

Read and follow all the safety precautions and instructions 

before installing and working with the equipment. 

                         !  

DANGER 

HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC 

FLASH 

 

Apply appropriate personal protective equipment(PPE) and 

follow safety work practices 

 

Only qualified electrical workers should install this equipment. 

Such work should be performed only after reading this entire 

set of instructions. 

 

If the equipment is not used in the manner specified by the 

manufacturer, the protection provided by the equipment 

may be impaired. 

 

NEVER work alone. 

 

The successful operation of this equipment depends upon 

proper handling, installation and operation. Neglecting 

fundamental installation requirements may lead to personal 

injury as well as damage to electrical equipment or other 

property. 

 

NEVER bypass external fusing. 

Failure to follow these instructions will result in death or serious 

injury. 

 

EAPL is not responsible for any consequential damages arising 

out of use of our products, though the technology is cautiously 

chosen and implemented like any other well designed good 

electric device.  

Tools and Fasteners 

Kindly use star – type screw driver for tightening the screws. 

NOTE:

 Installation should include a disconnecting device, like 

switch or circuit breaker, with clear ON/OFF markings, to turn-

off the auxiliary supply (control power).The disconnecting 

device should be within the reach of the equipment and the 

operator. 

 
 
 

OD RH YN 610002 REV 02/23-08-2021 

Page 1 of 2 

Reviews: