European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH           [email protected]              Tel: +44 (0)208 743 8880 

                                                                                                                                                             www.e2s.com             Fax: +44 (0)208 740 4200 
Document No. D211-00-671-IS     Issue:  A                        29-11-19               Sheet 1 of 11 

INSTRUCTION & SERVICE MANUAL 

D2xC2LD3 ALARM HORN AND LED 

For Use In Hazardous Locations 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

1) 

Warnings 

 DO NOT OPEN WHEN AN EXPLOSIVE 

ATMOSPHERE IS PRESENT 

 DO NOT OPEN WHEN ENERGISED 

 POTENTIAL ELECTROSTATIC CHARGING 

HAZARD - CLEAN ONLY WITH A DAMP 
CLOTH 

 DO NOT PAINT 

 

Avertissement: 

 NE PAS OUVRIR UN PRESENCE 

D’ATMOSPHERE EXPLOSIVE 

 NE PAS OUVRIR ENERGIE 

 DANGER POTENTIEL CHARGE 

ÉLECTROSTATIQUE - NETTOYER 
UNIQUEMENT AVEC UN CHIFFON HUMIDE 

 NE PAS PENINTURER 

 

2) 

Rating & Marking Information 

 

2.1  Public Mode Fire Alarm Ratings 

 
The  D2xC2LD3DC024  is  certified  for  use  as  a  public  mode 
audible  and  visual  alarm  device  in  accordance  with  UL464 
Tenth  Edition  /  CAN/ULC-S525  Fourth  Edition  and  UL1638 
Fifth Edition / CAN/ULC-S526 Fourth Edition. 
 
For  use  in  public-mode  fire  alarm  systems  the  equipment 
must  be installed  without  the wire  guard  or  plastic lens  cover 
on the beacon. 
 
For light output ratings of the beacon see section 12. 
 
The  sounder  section  produces  a  sound  pressure  level  above 
75dB(A) at 10 feet: 
 
For  Fire  Alarm  applications,  the  Sounder  Volume  must  be  at 
the highest setting, (see volume control section). 

 

The sounder section produces a sound pressure level above 
75dB(A) at 10 feet. 
 
For Fire Alarm applications, the Sounder Volume must be at 
the highest setting, (see volume control section).  

For fire alarm use, the temporal pattern tone No. 12 as per the 
tone table provided in these instructions must be selected. This 
tone produces a minimum sound pressure level of:  
 
CAN/ULC-S525: 100.4dB(A)* at 10 feet.  

(*Tested in an anechoic room)  

UL464: 92.2dB(A)

† 

at 10 feet.  

(

Tested in a reverberation room)

 

 
Testing of synchronization requirements of UL1971 & UL1638 / 
CAN/ULC-S526  were  conducted  by  UL  using  a  total  of  6  units 
connected to the same wire run. Auto-synchronization does not 
require  the  use  of  any  external  sync  modules  or  protocols. 
Providing the correct cable has been selected (see section 6) an 
unlimited  number  of  units  will  remain  synchronized  when 
powered from the same source. 
 

2.2  Private Mode Fire Alarm Ratings 

 
The  D2xC2LD3DC024  is  approved  for  use  as  an  Audible  and 
Visual  Appliance for  use  in  Private  Mode  Fire  Alarm  System  in 
accordance  with  UL464  Tenth  Edition  /  CAN/ULC-S525  Fourth 
Edition  and  UL1638  Fifth  Edition  /  CAN/ULC-S526  Fourth 
Edition. 
 
For use in private-mode fire alarm systems the equipment must 
be  installed  without  the  wire  guard  or  plastic  lens  cover  on  the 
beacon. 
 
For light output ratings see section 12. 

 

2.3  NEC & CEC Class / Division Ratings for US / Canada 

 
The  D2xC2LD3  LED  beacon  complies  with  the  following 
standards: 
 

UL1971 Ed. 3 2018 

 

UL1638 Ed. 5 2017 / CAN/ULC-S526 Ed. 4 
UL464 Ed. 10 2017 / CAN/ULC-S525 Ed. 4 
CSA C22.2 No. 205-17 
ANSI/ISA 12.12.01-2015 
CSA C22.2 No. 213-16 

 
The D2xC2LD3 LED beacon is rated as follows: 
 

Class I Div 2 ABCD T4 Ta -40°C to +50°C 
Class II Div 2 FG T6 Ta -40°C to +50°C 
Class III Div 1&2 Ta -40°C to +50°C 

 
The certification approval has validated continuous use up to 
38°C and are for transient use up to 50°C ambient. 
 
Installation must be carried out in compliance with the National 
Electric Code / Canadian Electric Code 
 

2.4  NEC Class / Zone ratings US 

 
The  D2xC2LD3  LED  beacon  complies  with  the  following 
standards: 
 

UL 60079-0-2017 
UL 60079-15-2017 
UL 60079-31-2015 

 
The D2xC2LD3 LED beacon is rated as follows: 
 

Summary of Contents for D2xC2LD3

Page 1: ...rovided in these instructions must be selected This tone produces a minimum sound pressure level of CAN ULC S525 100 4dB A at 10 feet Tested in an anechoic room UL464 92 2dB A at 10 feet Tested in a reverberation room Testing of synchronization requirements of UL1971 UL1638 CAN ULC S526 were conducted by UL using a total of 6 units connected to the same wire run Auto synchronization does not requi...

Page 2: ... the latest issue of the following standards EN60079 14 IEC60079 14 Explosive atmospheres Electrical installations design selection and erection EN60079 10 1 IEC60079 10 1 Explosive atmospheres Classification of areas Explosive gas atmospheres EN60079 10 2 IEC60079 10 2 Explosive atmospheres Classification of areas Explosive dust atmospheres 2 7 Ingress Protection Ratings The product is rated for ...

Page 3: ...rop depends on The total current draw of the devices installed on this cable run The wire size and total length of the cable run determining the total resistance of this cable run The minimum output voltage supplied by the power supply The voltage drop and input voltage at the point of use can be calculated as follows Total Wire resistance Wire resistance 1000ft x length of cable run x 2 length of...

Page 4: ...k a ve supply line to the S2 terminal Stage three S3 operation Power ve and ve link a ve supply line to the S3 terminal Stage four S4 operation Power ve and ve link a ve supply line to both the S2 S3 terminals Strobe will continue to flash during alarm horn S2 S3 S4 stages Fig 4 Terminals 9 Earthing The beacon bas has both internal and external earth points please see fig 5 The sounder PCBA also h...

Page 5: ...tput set the potentiometer fully clockwise Fig 8 Location of field controls 11 2 Tone Selection The DxC2 alarm horns have 64 different tones The tones are selected by operation of the tone setting DIP switches see Fig 9 10 on the PCB The alarm horns can also be switched to sound the second third and fourth stage alarm tones The tone table Table 1 shows the switch positions for the 64 tone and whic...

Page 6: ...he equipment should only be carried out by suitably qualified personnel in accordance with the current relevant standards IEC EN60079 19 Explosive atmospheres Equipment repair overhaul and reclamation IEC EN60079 17 Explosive atmospheres Electrical installations inspection and maintenance To avoid a possible ELECTROSTACTIC CHARGE the unit must only be cleaned with a damp cloth Units must not be op...

Page 7: ...0 75 90 90 30 45 60 75 Fig 12 Horizontal dispersion angles for wall mounting Table 3 Horizontal Light Output Dispersion for Wall Mounting Viewing Angle Of Rating Intensity cd at 1Hz flash rate Intensity cd at 1 33Hz flash rate Intensity cd at 1 5Hz flash rate Intensity cd at 2Hz flash rate 0º 100 77 4 74 5 74 6 79 3 5º 90 69 6 67 0 67 2 71 4 10º 90 69 6 67 0 67 2 71 4 15º 90 69 6 67 0 67 2 71 4 20...

Page 8: ...5 74 6 79 3 5º 90 69 6 67 0 67 2 71 4 10º 90 69 6 67 0 67 2 71 4 15º 90 69 6 67 0 67 2 71 4 20º 90 69 6 67 0 67 2 71 4 25º 90 69 6 67 0 67 2 71 4 30º 75 58 0 55 8 56 0 59 5 35º 75 58 0 55 8 56 0 59 5 40º 75 58 0 55 8 56 0 59 5 45º 75 58 0 55 8 56 0 59 5 50º 55 42 6 41 0 41 0 43 6 55º 45 34 8 33 5 33 6 35 7 60º 40 30 9 29 8 29 9 31 7 65º 35 27 1 26 1 26 1 27 8 70º 35 27 1 26 1 26 1 27 8 75º 30 23 2...

Page 9: ... nominal rms current at nominal voltage max rms current at worst case voltage in voltage range 14 2 Surge current for Fire Alarm system use Table 7a Beacon Surge Currents Model Nom Voltage Voltage Range Flash Rate Setting Init Peak Surge Current Init RMS Surge Current D2xC2LD3DC024 24Vdc Regulated 16 33Vdc 1Hz 60fpm 1 18A 950mA 1 33Hz 80fpm 1 22A 998mA 1 5Hz 90fpm 1 2A 990mA 2Hz 120fpm 1 22A 980mA...

Page 10: ...0 5s off x3 1s gap ISO 8201 Temporal Pattern 0 1 0 1 0 0 44 1 8 12 1000Hz 0 5s on 0 5s off x3 1s gap ISO 8201 Temporal Pattern 1 1 0 1 0 0 44 1 8 13 422 775Hz 0 85 on 0 5 off x3 1s gap NFPA Temporal Coded 0 0 1 1 0 0 44 1 8 14 1000 2000Hz 1Hz Singapore 1 0 1 1 0 0 23 3 35 15 300Hz Continuous 0 1 1 1 0 0 44 24 35 16 440Hz Continuous 1 1 1 1 0 0 44 24 35 17 470Hz Continuous 0 0 0 0 1 0 44 24 35 18 5...

Page 11: ... 44 24 12 49 560 1055Hz 0 18Hz Sweeping 0 0 0 0 1 1 44 24 12 50 560 1055Hz 3 3Hz Sweeping 1 0 0 0 1 1 44 24 12 51 600 1250Hz 0 125Hz Sweeping 0 1 0 0 1 1 44 24 12 52 660 1200Hz 1Hz Sweeping 1 1 0 0 1 1 64 24 12 53 800 1000Hz 1Hz Sweeping 0 0 1 0 1 1 56 24 12 54 800 1000Hz 7Hz Sweeping 1 0 1 0 1 1 57 24 12 55 800 1000Hz 50Hz Sweeping 0 1 1 0 1 1 54 24 12 56 2400 2900Hz 7Hz Sweeping 1 1 1 0 1 1 57 2...