1) Introduction 

 
The BExL25E and BExL15E are second generation flameproof 
/  increased  safety  loudspeakers  which  are  certified  to  the 
European  Standards  EN  50014:  1992,  EN  50018:  1994  and 
EN50019:  1994  and  meet  the  requirements  of  the  ATEX 
directive 94/9/EC. The loudspeakers can be used in hazardous 
areas  where  potentially  flammable  atmospheres  may  be 
present. There are three versions of each loudspeaker, 8 ohm, 
16  ohm  or  100V  Line  transformer.  On  100V  line  transformer 
units  there  are  four  output  tappings  for  each  size  of 
loudspeaker.  The  BExL25E  unit  produces output  levels  in  the 
117dB(A)  range  and  the BExL15E  unit  produces output levels 
in  the  112dB(A)  range.  Both  loudspeakers  can  be  used  in 
Zone 1 and Zone 2 areas with gases in groups IIA, IIB and IIC 
and temperature Classifications of T1, T2, T3 and T4. 

 

2)  

Marking

 

 
All  units  have  a  rating  label,  which  carries  the  following 
important information:- 
 
Unit Type No.     

BExL25E   or   BExL15E

 

 
Impedance:        8 ohm or 16 ohm   

            100V Line 

 

        

Code:                 

EEx de IIC T4 (T

amb.

 –50 to +55

°

C) 

 
Certificate No.

   KEMA 99ATEX6312

 

 

 

 

 

 
W arnings: 

 DO NOT OPEN WHEN AN EXPLOSIVE  

                         

     GAS ATMOSPHERE IS PRESENT 

 

      COVER BOLTS CLASS A4-80 
 

     USE HEAT RESISTING CABLES AND CABLE GLANDS 

 

        (Rated 95ºC) AT AMB. TEMPERATURES OVER 40ºC 

 
Year of Construction / 
Serial No.  

 

i.e.   02 / 1L43000001

 

 

 

3) 

Type Approval Standards

 

 

The  loudspeakers  have  an  EC  Type  examination  certificate 
issued  by  KEMA  and  have  been  approved  to  the  following 
standards:- 

 

EN 50014 : 1992  + prA1    General Requirements 
EN 50018 : 1994  + prA1    Flameproof Enclosure ‘d’ 
EN 50019 : 1994  + prA1  Increased Safety ‘e’ 

 

 

 
 

4) 

Installation Requirements

 

 

The  loudspeakers  must  be  installed  in  accordance  with  the  
latest  issues  of  the  relevant  parts  of  the  BS  EN  60079 
specifications  or  the equivalent  IEC specifications  – Selection, 
Installation  and  maintenance of electrical  apparatus  for use in 
potentially  explosive 

atmospheres  (other  than 

mining  

applications or explosive processing and manufacture):- 
 
BS EN 60079-14 : 1997 

Electrical Installations in Hazardous 

 

 

 

Areas (other than mines)

 

BS EN 60079-10 : 1996 

Classification of Hazardous Areas

 

 
The  installation  of  the  units  must  also  be  in  accordance  with 
any  local codes that may apply and should only be carried out 
by  a  competent  electrical  engineer  who  has  the  necessary 
training. 

 

5) 

Zones,  Gas  Group,  Category  and  Temperature 
Classification 

 

The BExL25E and BExL15E loudspeakers have been certified 
EEx de IIC T4 (Tamb. –50 to +55ºC). This means that the units  
can be installed in locations with the following conditions:- 
 

Area Classification: 

 

Zone 1 

Explosive  gas  air  mixture  likely  to  occur  in 
normal operation. 

Zone 2 

Explosive  gas  air  mixture  not  likely  to  occur, 
and if  it does, it will only exist for a short time. 

  

Gas Groupings: 

 

Group IIA 

Propane 

Group IIB 

Ethylene 

Group IIC 

Hydrogen and Acetylene 

 

Equipment Category: 

2G

 

  

 

Temperature Classification: 

 

T1 

400

o

 C  

T2 

300

o

 C 

T3 

200

o

 C 

T4 

135

o

 C 

 

Ambient Temperature Range: 

 

   

         -50

°

C to +55

°

 

6) 

Loudspeaker Location and Mounting

 

 

The  location  of  the  loudspeakers  should  be  made  with  due 
regard  to  the  area  over  which  the  unit  must  be  audible.  The 

0344 

II  2G 

Epsilon x: 
Gas Group and 
Category: 

CE Marking: 
Notified Body No. 
 