background image

 

 

__________________________________________________________________________________________________________________________________ 

European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH           [email protected]              Tel: +44 (0)20 8743 8880 

                                                                                                                                                             www.e2s.com             Fax: +44 (0)20 8740 4200 
Document No. IS 2425-P      Issue B     17-04-02                                Sheet 1 of  4 

 

          INSTRUCTION MANUAL  (ATEX) 

BExA120D and BExA110D 

Flameproof Appello Speech Sounders

 

 
1) Introduction 

 
The  BExA120D  and  BExA110D  are  second  generation 
flameproof Appello Speech Sounders which are certified to the 
European  Standards  EN  50014:  1992  and  EN  50018:  1994 
and meet the requirements of the ATEX directive 94/9/EC. The 
units,  which  have  a  facility  to  record  a  message  of  up  to  16 
seconds  in  duration,  can  be  used  in  hazardous  areas  where 
potentially  flammable  atmospheres  may  be  present.  The 
speech  message  can  be  preceded  by  one  of  nine  different 
alarm  tones  (

see  tone  table  on Page 4

).    The BExA120D  unit 

produces  output  levels  in  the  112dB(A)  range  and  the 
BExA110D unit produces output levels in the 110dB(A) range. 
Both  sounders can  be  used  in  Zone 1  and  Zone 2 areas  with 
gases  in  groups  IIA,  IIB  and  IIC  and  temperature 
Classifications of T1, T2, T3 and T4.

 

 

2)  

Marking

 

 
All  units  have  a  rating  label,  which  carries  the  following 
important information:- 
 
Unit Type No.     

BExA120D   or   BExA110D

 

 
Input Voltage:    DC Units    24V   

            AC Units    230V or 115V 

 

        

Code:                 

EEx d IIC T4 (T

amb.

 –50 to +55

°

C) 

 

Certificate No.

   KEMA  99ATEX6312

 

 

 

 

 

 
W arnings: 

 DO NOT OPEN WHEN AN EXPLOSIVE  

                         

     GAS ATMOSPHERE IS PRESENT 

 

      COVER BOLTS CLASS A4-80 
 

     USE HEAT RESISTING CABLES AND CABLE GLANDS 

 

        (Rated 95ºC) AT AMB. TEMPERATURES OVER 40ºC 

 
Year of Construction / 
Serial No. 

 

i.e.  02 / 1A22000001

 

 

3) 

Type Approval Standards

 

 

The Appello's have an EC Type examination certificate issued 
by KEMA and have been approved to the following standards:- 

 

EN 50014 : 1992  + prA1    General Requirements 
EN 50018 : 1994  + prA1    Flameproof Enclosure ‘d’   
 
 

 

4) 

Installation Requirements

 

 
The units must be installed in accordance with the latest issues 
of the  relevant  parts of  the BS EN  60079 specifications or  the 
equivalent  IEC  specifications  –  Selection,  Installation  and  
maintenance  of  electrical  apparatus  for  use  in  potentially 
explosive  atmospheres  (other  than  mining  applications  or 
explosive processing and manufacture):- 
 
BS EN 60079-14 : 1997 

Electrical Installations in Hazardous 

 

 

 

Areas (other than mines)

 

BS EN 60079-10 : 1996 

Classification of Hazardous Areas

 

 
The  installation  of  the  units  must  also  be  in  accordance  with 
any  local codes that may apply and should only be carried out 
by  a  competent  electrical  engineer  who  has  the  necessary 
training. 

 

5) 

Zones,  Gas  Group,  Category  and  Temperature 
Classification 

 

The  BExA120D and BExA110D  Appello’s have  been  certified 
EEx d IIC T4 (Tamb. –50 to +55ºC). This means that the  units  
can be installed in locations with the following conditions:- 
 

Area Classification: 

 

Zone 1 

Explosive  gas  air  mixture  likely  to  occur  in 
normal operation. 

Zone 2 

Explosive  gas  air  mixture  not  likely  to  occur, 
and if  it does, it will only exist for a short time. 

  

Gas Groupings: 

 

Group IIA 

Propane 

Group IIB 

Ethylene 

Group IIC 

Hydrogen and Acetylene 

 

Equipment Category:

 

2G

 

  

 

Temperature Classification: 

 

T1 

400

o

 C  

T2 

300

o

 C 

T3 

200

o

 C 

T4 

135

o

 C 

 

Ambient Temperature Range: 

 

   

         -50

°

C to +55

°

 

6) 

Location and Mounting

 

 

The location of the Appello Speech Sounders should be made 
with due regard to the area over which the recorded messages 
must be audible. The Appello's should only be fixed to services 
that can carry the weight of the unit. 
 

0344 

Epsilon x: 
Gas Group and 
Category: 

CE Marking: 
Notified Body No. 
 

II  2G 

Reviews: