manualshive.com logo in svg
background image

Artisan Technology Group 

is your source for quality 

new and certified-used/pre-owned equipment

• 

FAST SHIPPING AND 

DELIVERY

• 

TENS OF THOUSANDS OF 

IN-STOCK ITEMS

•  EQUIPMENT DEMOS
• 

HUNDREDS OF 

MANUFACTURERS 

SUPPORTED

•  LEASING/MONTHLY

 

RENTALS

•  ITAR CERTIFIED

           

SECURE ASSET 

SOLUTIONS

SERVICE CENTER REPAIRS

Experienced engineers and technicians on staff 

at our full-service, in-house repair center

WE BUY USED EQUIPMENT

Sell your excess, underutilized, and idle used equipment 

We also offer credit for buy-backs and trade-ins

www.artisantg.com/WeBuyEquipment

                        

REMOTE INSPECTION

Remotely inspect equipment before purchasing with 

our interactive website at

 

www.instraview.com

LOOKING FOR MORE INFORMATION? 

Visit us on the web at

 

www.artisantg.com

    

for more 

information on price quotations, drivers, technical 

specifications, manuals, and documentation

Contact us:

 

 

(888) 88-SOURCE  |  [email protected]  |  www.artisantg.com

SM

View

Instra

Содержание LOVE CONTROLS DIVISION Iso Verter II 4380

Страница 1: ...CURE ASSET SOLUTIONS SERVICE CENTER REPAIRS Experienced engineers and technicians on staff at our full service in house repair center WE BUY USED E Sell your exce We also offer www artisan REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR Visit us on the information o specifications Contact us 888 88 SOURCE sales artisantg...

Страница 2: ... using the procedure on page 4 WARNING Do not attempt to operate or calibrate this device with the cover removed Potentially lethal voltage is present on some of the internal components Make sure that the cover is firmly in place before plugging into the socket Wiring Wire the mounting socket as shown in the drawing shown in Figure 2 For DIRECT ACTING inputs wire the positive lead to terminal five...

Страница 3: ...ON and turn switch five OFF 5 For ZERO SUPPRESSION eg 4 to 20 mA turn switch four OFF and turn switch five ON 6 For DIRECT ACTING INPUT turn switch six OFF 7 For REVERSE ACTING INPUT turn switch six ON and reverse input wiring RANGE SELECT SWITCH BANK Turn ON the switch for the scale desired All other switches should be OFF If BI POLAR INPUT is selected the scale will be MINUS SELECTION to PLUS SE...

Страница 4: ... mA turn switch six OFF and turn switch seven ON If BIPOLAR or REVERSE ACTION is selected do not use the ZERO SUPPRESSION switch Use the ZERO adjustment to suppress the output 7 Switch eight is always OFF It is not connected to any circuitry If switch eight is turned ON there is no effect on the operation of the device RANGE SELECT SWITCH BANK Turn ON the switch for the scale desired All other swi...

Страница 5: ... low end output 4mA for example 3 Apply the appropriate input for the high end of the scale 4 Adjust the SPAN screw for the desired high end output 20mA for example 5 Repeat as necessary Note Instrument is factory calibrated for 4 to 20 mA Uni Polar Direct Acting Input and 4 to 20 mA Uni Polar Output Any change from this default condition may require field re calibration to ensure accuracy of zero...

Страница 6: ...CURE ASSET SOLUTIONS SERVICE CENTER REPAIRS Experienced engineers and technicians on staff at our full service in house repair center WE BUY USED E Sell your exce We also offer www artisan REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR Visit us on the information o specifications Contact us 888 88 SOURCE sales artisantg...

Отзывы: