background image

Quality –

 

Built In

 

 

 

 

ASSEMBLY INSTRUCTIONS

 

 

MK3B 

 

 

BASE SIZE 3380mm x 3380mm

 

Summary of Contents for MK3B

Page 1: ...Quality Built In ASSEMBLY INSTRUCTIONS MK3B BASE SIZE 3380mm x 3380mm ...

Page 2: ... checklist If you are making your own floor refer to Raised Base Plate section now Do not attempt to build your shed in high winds Beware of sharp edges Protect your eyes and ears Use electric tools with care Use a Safety Trip Switch It is easier and quicker if this shed is erected by two people Your shed must be level Achieve this by either levelling the ground or by using blocks If you shed is t...

Page 3: ...ed Window Frame Glaze Beads Glass Louvre Window Frame Glass Window Hardware Pack 3 700m Roof Sheets Security Double Door Hardware Pack Alarm MA20 Shed light Bolt Down Kit Peg Down Kit 1 850m Flat Roof Sheet Jack Studs 140 x 45mm Roof Sheets 1 850m Clear Roof Panel 1 175m Ridge Flashing Clear Roof Hardware Pack 1 4 3 700m 1 Jack Studs 60 x 45mm 0 200m KIWI MK3B PARTS LIST 1 Duratuf Riveter ...

Page 4: ......

Page 5: ... in remaining two studs using 785m Nogs to get correct po sition Position Nogs centrally between Plates and nail in place Step 3 End Wall Select one 3 380m Base Plate Green one 3 380m Top Plate Red three Studs Yellow and two 789m Nogs Lay out Plates and one Stud on a flat surface and nail Stud centrally between Plates Nail re maining Studs to Plates using 789m Nogs to get the cor rect position Pos...

Page 6: ...k Stud and skew nail in place using two 75mm nails each end Pre drilling holes before nailing will prevent timber from splitting Step 6 Place intermediate Roof Beams by using Roofing Nogs to determine correct position see fig 2 Nail intermediate Roof Beams in place Nail 70 x 45mm Roofing Nogs in place End Wall Step 7 Place Frame in correct position checking the shed is square and level Dynabolt Fr...

Page 7: ... Tack on a wall sheet means to use minimum nails hammered partly in to hold Wall Sheets in position Should a Wall Sheet need to be re positioned the nails can easily be prized out If a window is required identify Wall Sheet s with window hole pre cut Lean up Wall Sheets where window s are to be located Note When fitting Gable End Sheets ensure they overlap correctly fig 1 The overlap direction may...

Page 8: ...op Plate tack in place Repeat with remaining two sheets Step 4 Nailing Off Nail one 30mm Clout each side of the Rib two per Pan into the Top Plates and Bottom Plates Nail Wall Sheets to mid wall Nogs one per pan Nail each corner Wall Sheet to Studs using two 30mm Clouts evenly spaced Gable Ends When nailing Gable Wall Sheets to the Top Plate use a String Line At the top of the gable nail one 30mm ...

Page 9: ...rill holes in each corner and nail Window Frame to framing using 50mm nails Step 4 If the Window is in the gable end tempo rarily position the Over Panel above Win dow Frame Following the same angle as the gable mark and cut to suit Step 5 Rivet Over Panel to the Window Frame with rivets 588mm Step 1 Lay out the two window studs 883mm and Nog 634mm on a flat surface Position Nog and nail in place ...

Page 10: ...ottom Plates and hard against Stud Attach Door Jamb Flashing with three rivets into Rib on the outside and three 30mm clouts into studs on the inside Repeat with the other Door Jamb Step 3 Fit Corner Flashing 101 over corner Ribs with the top flush with the top of the Top Plate Rivet in place with six rivets three each side Repeat with other three Corner Flashings When fitting Corner Flashings on ...

Page 11: ...E BRACK Step 5 Bottom Door Guide Slide the Door to the corner of the shed Place the Door Guide 108 over the Guide Brackets on the door and align the end of the Door Guide flush with outside of the right hand corner flashing Step 6 Lift the door guide up approximately 3mm so that the Door will Slide freely Pre drill a hole through the door guide and the end rib of the cladding and screw in place us...

Page 12: ...osition first Roof Sheet centrally over Ridge Beam on the right hand end of shed with the LIP on the left hand side For sheds with a Clear Roof Panel go to the next page Position the next Roof Sheet Ensure it overlaps correctly then rivet together one rivet in the centre and one 600mm and 1200mm down from the centre on both sides Fit remaining Roof Sheet Step 3 Centralize Roof at the other end and...

Page 13: ...rews Screw one 50mm roofing screw into ridge beam through each rib on overlap one screw per sheet Mould the soft edge on the flashing down into the pans of the roof sheet to prevent roof leaks Step 4 Continue to fasten roof sheets as per step 4 on previous page pg11 Note When screwing through the clear panel pre drill a 6mm hole TOP PLATE JACK STUD RIDGE BEAM 30mm CLOUT RIDGE FLASHING ROOFING SCRE...

Page 14: ...ends Posi tion Spouting C103 on the shed and rivet to barge Flashing at each end Repeat with other Spouting Step 2 Centralise Barge Flashing on gable end and rivet in place one rivet into every second Rib Fit two rivets through top of Barge into Rib Repeat with other Barge Flashing Check Spoutings are straight then rivet to Roof one rivet every second Rib ...

Page 15: ... Plate This will stop water flowing in between the Base Plate and Floor The Floor should be made 15mm smaller than Base Size Note Although it is not essential fitting Damp Proof Course in between the Base Plate and the Floor will give added protection against moisture CLEAN UP Remove all swarf drill filings with a soft brush or rag Hose down roof and walls thoroughly For Coloursteel sheds use touc...

Page 16: ...arried out in accordance with instructions below Should the cladding fail to perform as specified above the liability of Riverlea Group Ltd shall in all cases be limited to replacing or repairing the defective product The balance of the original warranty will cover any repaired or replaced material Riverlea Group Ltd will not be liable for any consequential loss or damage labour or transport charg...

Page 17: ......

Page 18: ......

Reviews: