Drifton high precision dispenser for liquid 

 

Operation Manual (GB) 

 

Drifton 206-DF

 

 

 

   

 

Summary of Contents for 206-DF

Page 1: ...edoereholmen 84 2650 Hvidovre Denmark TEL 0045 5372 8090 FAX 0045 3677 3633 Website www drifton eu www drifton dk E mail info drifton dk Drifton high precision dispenser for liquid Operation Manual GB Drifton 206 DF ...

Page 2: ...testing procedures Review the helpful information we have included which is based on several years of industrial dispensing experience Most questions you will have are answered in this Operation Manual However if you need assistance please do not hesitate to contact Drifton A S at telephone 0045 5372 8090 or info drifton dk or an authorized distributor Our goal is to build not only the finest equi...

Page 3: ...rawing 6 Drifton 206 DF Control Panel 7 Drifton 206 DF Setup for Testing 8 Application Art 9 1 Making Timed Deposits of Medium to Thick Fluids 9 2 Changing Deposit Size Drawing Stripes 9 3 Setting the Deposit Size 9 4 How to Use the Vacuum Control 10 5 Piston Function 11 6 Filling the Syringe Barrel 11 Suggestions on Settings 12 Helpful Hints 12 Troubleshooting Guide 13 Guarantee 14 ...

Page 4: ... dispensers Next We will tell you how to dispense low viscosity fluid using the vacuum control and how to dispense high viscosity liquid Principles Drifton high precision air pressure regulated dispenser ensures a very uniform dispensing of media Due to a high quality solenoid valve it can dispense repeatedly very consistent and fast Drifton dispenser components syringes pistons high precision tip...

Page 5: ... Remove the end cap connect to the adapter assembly twist clockwise to lock 8 Push the black male quick connector on the syringe barrel adapter assembly into the front of the dispenser 9 Remove the tip cap and replace it with an appropriate Drifton tip cap Place the syringe barrel in the barrel holder 10 Initial setup is now complete At this point you are now ready to set up your dispensing flow r...

Page 6: ...Input 7KgF cm2 Air Output 0 1 7KgF cm2 Repeatability 0 01 Min depot 0 005ml Work Frequency 600 times minute Input AC 110V or 220V 50Hz Internal Voltage 24 VDC Input Power Required 15W Weight 3 5Kg Cabinet Dimensions 28 1x21x7cm Approvals CE Drifton 206 DF Connections Drawing Foot pedal switch Power line Air input hose Adapter assembly Male quick connect ...

Page 7: ...F Control Panel Pressure gauge Pressure regulator Vacuum regulator Barrel connector Time setting Interval setting Power switch Power input receptacle Air input connect Foot pedal switch finger switch Air exhaust port ...

Page 8: ...o lock Pressure regulator Turn clockwise increase pressure Turn counterclockwise decrease pressure Third Press power switch to turn on the dispenser Fourth Press the Auto Man button to choose the Man The time display will automatically show the best bits of time example 0 100 seconds then press any one of 1 8 to set the time already almost complete set of quantitative touch the foot switch every t...

Page 9: ...dot size slightly increase output air pressure or increase tip size or both To make stripes press the Man button With the tip in contact with the test sheet press and hold down the foot pedal while making a bead or stripe Remember always bring the tip into contact with the work surface at the illustrated angle after the tip is in position pres the foot pedal release pedal and remove tip by lifting...

Page 10: ... Press the foot pedal Check the dot size Increase or decrease by adjusting pressure or time If you choose not to use the piston please follow these instructions carefully 1 While holding the barrel upright in one hand twist on an orange tip cap Using the small funnel fill about 2 3 full with your fluid 2 Open the safety clip and attach the barrel to the adapter 3 Close the safety clip as tight as ...

Page 11: ... the piston makes it easy and safe to change tips without dripping 5 Press the Man button 6 With the barrel pointing downward over a container unsnap the safety clip Then press the foot pedal to fill the tip Note For best results we strongly recommend that you use a piston as part of your dispensing system 6 Filling the Syringe Barrel Caution Do not completely fill syringe barrels The optimum fill...

Page 12: ...ith very small deposit settings The ideal setup matches air pressure and tip size to create a workable flow rate no splashing but not too slow either 6 With any fluid always give the air pressure time to do its job Moderate time and pressure provides the best results since dispensing pressure remains at its peak for a longer period of time Helpful Hints 1 There are three core variables to the disp...

Page 13: ...ot come loose Check to make sure that the regulator is turned off fully counterclockwise If dispensing high viscosity materials try increasing output air pressure slightly Vacuum level is set to high Barrel adapter safety clip may be clamped shuts Inconsistent dispense output Check the dispensing tip barrel and material for possible contamination or clogs Note Dispensing System Components are disp...

Page 14: ...soever of merchantability or fitness for a particular purpose In no event shall be liable for incidental or consequential damages The following situations are not in the scope of warranty users should pay the maintenance costs 1 The mistake of operation or transport causes damage to the machine by the user 2 Replacement of components or repair of the machine by a repairer which is not designated b...