background image

 

 

 

USER'S MANUAL

  

 

 

 

DG-NAS1000

Rugged Railway NAS with POE Support

Summary of Contents for DG-NAS1000

Page 1: ...USER S MANUAL DG NAS1000 Rugged Railway NAS with POE Support ...

Page 2: ...a visualizzare in questo punto utilizzare la scheda Home Trademarks All trademarks both marked and unmarked appearing in this document are the property of their respective owners Revision History Revision Description Date 1 0 First release February 2013 ...

Page 3: ...1 Contents of the box 12 Product specifications 13 Front panel Layout 14 System installation and use 16 Unpacking 17 Usage 17 Warnings about electrical and power connections 17 Installation notes 18 Installation procedure 19 How to connect the system to the Ethernet network 22 How to access the system 22 Physical characteristics 23 Operating characteristics 23 Environmental specifications 23 Mecha...

Page 4: ... This page has been intentionally left blank ...

Page 5: ...oughout this manual The following alerts indicate potentially dangerous situations SYMBOL MEANING DANGER Information highlighting potential electrical shock hazards Personal injury or death could occur Damage to the system connected peripheral devices or software could occur Appropriate safety precautions should always be used these should meet the requirements set out for the environment that the...

Page 6: ...r to the system thoroughly review all installation operation and safety instructions Failure to install the system power supply correctly or to follow all operating instructions correctly may create an electrical shock hazard which can result in personal injury or loss of life and or damage to equipment or other property To avoid injuries always disconnect power and discharge circuits before touch...

Page 7: ... air circulation Do not block any ventilation openings Maintenance DANGER Never open dismantle or repair the device For your maintenance or repair requirement please contact a qualified Dragontech engineer If the device does not function correctly and you are unable to find a solution feel free to contact the Dragontech Technical Support Team If the equipment does not work properly especially if s...

Page 8: ...he use of the following symbol attached to the equipment packaging instruction literature or the guarantee sheet states that the device has been marketed after August 13th 2005 and implies that you must separate all of its components when possible and dispose of them in accordance with local waste disposal legislations Because of the substances present in the equipment improper use or disposal of ...

Page 9: ...sporting any module or system for any reason it should be packed using anti static material and placed in a sturdy box with enough packing material to adequately cushion it Warning Any product returned to Dragontech Systems that is damaged due to inappropriate packaging will not be covered by the warranty Device labelling On the rear side of the device you will find a label displaying the followin...

Page 10: ... This page has been intentionally left blank ...

Page 11: ... mounting brackets or inserted inside a security enclosure that has a locking mechanism and allows you to install the system while avoiding unauthorized removal The rugged design of NAS1000 systems allows their deployment in railway applications prone to harsh environmental conditions Figure 2 rear and front views 1 Network Attached Storage NAS is file level computer data storage connected to a co...

Page 12: ... 00 NAS POE 500 GB in RAID 1 or 1 TB aggregated HDD NAS 0200 01 NAS POE 100 GB in RAID 1 or 200 GB aggregated HDD coming enclosed within a Key locked Enclosure NAS 1000 01 NAS POE 500 GB in RAID 1 or 1 TB aggregated HDD coming enclosed within a Key locked Enclosure NAS CBL 01 M12 Male to M12 Male Connection Cable length 2 m NAS CBL 02 M12 Male to RJ45 Male Connection Cable length 2 m DragonTech ...

Page 13: ...n Class 0 IEEE 802 3af compliant Maximum Weight 3 Kg Maximum Power Consumption 12 W Overall Dimensions in millimetres W x H x L NAS 0200 00 and NAS 1000 00 models 171 0 x 59 5 x 285 0 NAS 0200 01 and NAS 1000 01 models 171 0 x 83 0 x 293 0 Cooling Fans Not required Passive heat sink provided Operating Temperature NAS 0200 00 and NAS 0200 01 models 25 C to 55 C 70 C for 10 minutes NAS 1000 00 and N...

Page 14: ...y 5 Spare 6 CPU power ON M12 connector layout and functionality Function 10 100 Mbps Ethernet with Power over Ethernet ETH1 Connector type Female box mounting Type 4 pin M 12 D Code Part Lumberg 0986 EFC 152 PIN FUNCTION PoE 1 TX Transmit Data 2 Rx Receive Data 3 TX Transmit Data 4 RX Receive Data Housing Shield 2 1 3 4 Handle M12 LED indicators 1 3 5 2 4 6 DragonTech ...

Page 15: ... This page has been intentionally left blank ...

Page 16: ...recautions as well as using good technical judgment whenever installing or using the device described in this manual WARNING The installation of the product described in this manual can be only performed by qualified personnel and must be carried out in accordance with the standards WARNING To avoid ESD Electro Static Discharge damage always use appropriate antistatic precautions i e use an antist...

Page 17: ...r other road users Optical disturbances Indicator control Brake lights Reversing lights Light bars for emergency system Warning indicators Lamps or Displays related to functions in clauses a or b that may be observed in the direct view of the driver Acoustic disturbances Anti theft alarm Horns Functions related to vehicle data bus functionality Data transmission on vehicle data bus systems which a...

Page 18: ... The device can operate in vertical transversal and longitudinal orientations WARNING Verify that the addition of the system does not cause instability or damage to the mounting location Firmly secure the system Be aware of potentially hazardous situation when mounting the system e g falling down If required use stiffeners to reinforce the mounting area NOTE When the unit is mounted ensure adequat...

Page 19: ...00 01 and NAS 1000 01 installation can be made using the two mounting brackets attached to the key locked enclosure How to install the NAS 0200 00 and NAS 1000 00 models NAS 0200 00 an d N AS 1000 00 m odels c ome pr ovided with t wo m ounting br ackets attached t he system Four M5 screws and washers can be used to secure the brackets in place Bracket 171 0 5 5 5 5 5 5 15 0 59 5 32 0 47 0 248 5 20...

Page 20: ... 01 and NAS 1000 01 models NAS 0200 01 and NAS 1000 01 models come enclosed within a key locked enclosure provided with two mounting brackets Four M5 screws and washers can be used to secure the brackets in place Bracket DragonTech ...

Page 21: ... Pull the handle and slide the system from the enclosure How to reinstall the system in the key locked enclosure 1 The security door must be open 2 Using the handle slide the system along the guiderails to insert it into the enclosure 3 Close the security door and close the latch of the locking mechanism Handle Locking mechanism Guiderail DragonTech ...

Page 22: ...tely turns itself ON How to access the system The NAS1000 will have the following fixed IP address 192 168 0 11 It is possible to access the NAS1000 as follows 1 Map a network drive using the folder 192 168 0 111 PUBLIC 2 Using a web browser Type the address 192 168 0 111 PUBLIC username admin password admin to configure the NAS1000 shared folders and users 3 Using a Secure Shell SSH protocol to e...

Page 23: ...perating Temperature Range NAS 0200 00 25 C 55 C 70 C for 10 minutes NAS 0200 01 25 C 55 C 70 C for 10 minutes NAS 1000 00 10 C 55 C 70 C for 10 minutes NAS 1000 01 10 C 55 C 70 C for 10 minutes Storage temperature range All 40 C 85 C Vibration The mechanical strength of the unit must meet the requirement of the category 1 class B defined in EN 50155 EMC Immunity and Emissions must meet the requir...

Page 24: ...nical characteristics Note All dimensions are in millimetres unless otherwise stated NAS 0200 00 and NAS 1000 00 models 171 0 5 5 5 5 5 5 15 0 59 5 32 0 47 0 248 5 207 0 254 0 221 5 285 0 153 0 129 0 DragonTech ...

Page 25: ...25 NAS 0200 01 and NAS 1000 01 models DragonTech ...

Page 26: ... This page has been intentionally left blank ...

Page 27: ... cable Performance criteria A Immunity to conducted disturbances inducted by radio frequency fields EN 50121 3 2 EN 61000 4 3 Test executed on Ethernet cable from 0 15 MHz to 80 MHz Performance criteria A Radiated radio frequency electromagnetic field immunity test EN 50121 3 2 EN 61000 4 3 Field strength 20V m from 80MHz to 1GHz 10V m from 1 4GHz to 2 1GHz and 5V m from 2 1GHz to 2 5GHz Performan...

Page 28: ...Dragontech Systems Ltd 508 5 F Mirror Tower 61 Mody Road TST East Kowloon Hong Kong www dragontech hk sales dragontech hk ...

Reviews: