TechMaster

Control Console

Owner's Manual

Dove Lighting Systems, Inc.

3563 Sueldo Street Unit E

San Luis Obispo, Ca 93401

+1 805 541 8292 fax +1 805 541 8293

[email protected] / www.dovesystems.com

Summary of Contents for TechMaster

Page 1: ...1 TechMaster Control Console Owner s Manual Dove Lighting Systems Inc 3563 Sueldo Street Unit E San Luis Obispo Ca 93401 1 805 541 8292 fax 1 805 541 8293 dove dovesystems com www dovesystems com ...

Page 2: ...2 TABLE OF CONTENTS 1 RECEIVING YOUR EQUIPMENT 2 FEATURES 3 SETUP AND CONNECTION 4 OPERATION 5 EXPANDING THE SYSTEM 6 TROUBLESHOOTING 7 OBTAINING SERVICE 8 WARRANTY INFORMATION ...

Page 3: ... is very important The TechMaster has been designed to make it as simple as possible The TechMaster must be connected to the dimmer pack through a control cable The cable uses five pin XLR connectors for standard DMX control The connectors are wired according to the diagram at right Plug the male end of the control cable into the female connector on the TechMaster Plug the female end of the contro...

Page 4: ...e switch and apply power after changing the switch In single scene mode the number of control channels is doubled For example on the TM TS12 24 the top row is channels 1 12 and the bottom row is channels 13 24 The hold button adds a virtual second scene so the operator can crossfade from one look to another even in single scene mode Here is an example 1 Remove power from controller 2 Set the SS 2S...

Page 5: ...it again turning off the red LED As long as no other buttons were hit in the chase record the old recorded chase is maintained To restore the default chase all channels in order press the chase record button then press the chase mode button The default chase will be loaded and start executing A chase can include up to 255 steps The chase is held in capacitor backed RAM The programmed chase is held...

Page 6: ...PM Pacific time for phone sup port at 805 541 8292 Please have a specific description of the problem preferably from personnel who were on site at the time If at all possible bring the telephone into the theatre and have the equipment at hand Do not open the unit for examination Dove Systems cannot provide phone support replacement parts or schematics for component level testing The TechMaster is ...

Page 7: ...ipment will be replaced or put in proper operat ing condition free of all charges except transportation The correction of any defects by re pair or replacement by the manufacturer shall constitute fulfillment of all obligations to the purchaser Manufacturer does not assume responsibility for unauthorized repairs to its appa ratus even though defective Manufacturer shall not be liable for any conse...

Reviews: