1.Simple introduction
ODT-8250 DMT adopts the dual-micro outdoor intruding detector which
includes energy-pile-up logical process ,logic dynamic time split technology.
It is the best choice of outdoor intruding detector for finance industry, business
and garden resident.
ODT-8250 DMT,the part of PIR adopts sophisticate columnar FRESNEL
technology, advanced radian design to improve the efficiency of energy receiving.
And combine the MW and PIR technoloy. MW detecting area and the PR detecting
area are overlap. High sensitivity but do not have any fault arming. The part of the
MW can caculate out the moving objects's speed and volume ans so on.
Cooperating with the advanced patent software technology can help make the
accurate judgement between the real intruder and some other interference resulting
in fault arming. Have a super high performance of detecting and anti-fault arming.
3.Installation
PIR channel
2.Specification
product name
ODT-8250 DMT
input voltage
12 VDC
most current62mA
meeting point rating 3W
125mA
most current
25 VDC
most voltage(DC resistent load);
sharing with the relay use the "C" down-lead's 4.7
1/2W resistant to protect
Remark
Please do not use on the load of capacitance or inductance
temperature rang
-10
C to +50 C.
MW frequency
0D850-F1
10.525GHz
0D850-F2: 10.588GHz
covering range
12m*12m
É Ï ¸ Ç
Ï Â ¸ Ç
P/N:20090801A01
25ft
15ft
5ft
0ft
1.5m
4.5m
7.5m
0ft
10ft
20ft
30ft
40ft
50ft
7.2m
9.6m
0m
2.4m
4.8m
12m
Please do not install the detector in the position of PIR or MW always in the status of alarming (LED is on). After right installation, turn down the LED.
Please do not towards to the direction of car driving.
Avoid installing at the place as the hanging sign and the trees can be blowed by the wind, and the other things at the place of sub-corving zone ,
and the corving zones where the wildness animals can intrude .Please check that the installing place is steady and non vibration.
Warning!!!
Warning!!!
Only after all the connection, then can turn on the power. Please do not place the detector at the area
with the redundant curing wiring. Please do not connect the terminals to the 25VDC power.
SELV
Some countries request the relay should be connected to the circuit with the SELV
Only after all the connection, then can turn on the power. Please do not place the detector at the area
with the redundant curing wiring. Please do not connect the terminals to the 25VDC power.
SELV
Some countries request the relay should be connected to the circuit with the SELV
3.2 Installing step
A. Use the screwdriver to open t
he top and then install
DIP swtich
tapmer switch
MW adjust
cable outlet
cable outlet
wiring hole
used after
the pulling
A. Drill at installing place
B. Induct the wiring to the shell from the back
C.fix the bottom shell in the wall with the
screwdriver
D. Combine the upper and lower lids
descriptions
Can choice the underside
installation, install on the wall with the 45,
bracket installing . And the bracket installing
is the most convenient way.
Back is the bracket installing place
bracket is optical