background image

Visit our Website for more information on this product

www.diversitech.ca

1200 55

th

 Avenue, Montreal, Quebec H8T 3J8

Tel:  1.800.361.3733  |  Fax: 1.514.631.9480  |   [email protected]

READ AND SAVE THESE INSTRUCTIONS

    FRED SR2 C

     FRED SR1 C

FRED SR2

FRED SR

Operation & Maintenance Manual

FRED SR | SR2 | SR1 C | SR2 C

Summary of Contents for FRED SR

Page 1: ...oduct www diversitech ca 1200 55th Avenue Montreal Quebec H8T 3J8 Tel 1 800 361 3733 Fax 1 514 631 9480 info diversitech ca READ AND SAVE THESE INSTRUCTIONS FRED SR2 C FRED SR1 C FRED SR2 FRED SR Oper...

Page 2: ...s 8 4 3 Pre Use Checklist 8 4 4 Principles of Operation 9 4 5 Failure Event 9 4 6 ICS 360 Injection Cleaning System 10 SECTION 5 MAINTENANCE TROUBLESHOOTING 10 5 1 To Maintain this Product Safely 10 5...

Page 3: ...of any and all components power switch must be off and the power source disconnected It is your responsibility to follow all applicable ANSI OSHA UL CSA National Local Fire Codes and other regulatory...

Page 4: ...combustible fumes or dusts are present until a qualified person has indicated it is safe to do so Never use or install equipment where the potential for combustible fumes or dusts are present without...

Page 5: ...6 5 5 0 10 13 FRED SR2 Portable Fume Collector with two externally articulated manual capture arms FRED SR2 2500 5 0 3P 60Hz 13 0 6 5 5 0 10 13 FRED SR2 C Fume Collector with two externally articulate...

Page 6: ...15 33 13 60 34 18 5 13 6 32 5 128 33 13 60 60 18 5 FRED SR Portable Fume Collector with Fume Tracker hands free capture arm FRED SR T 10 7 32 5 115 33 13 60 34 18 5 13 7 32 5 128 33 13 75 34 18 5 FRED...

Page 7: ...ulations 3 3 Tools Required 1 7 16 Socket or Wrench 2 9 16 Socket or Wrench 3 Torque Wrench The tools above are required for unit assembly 1 Immediately upon receiving the unit carefully examine the c...

Page 8: ...ion Inform all potential users of this equipment where they may find and review this manual The machine controls are basic and consist solely of a power switch with ON and OFF positions If the machine...

Page 9: ...Cleaning System If for some reason during operation there is an accident a blockage occurs the Minihelic displays abnormal pressure differences or the machine begins to act abnormally the operator sh...

Page 10: ...r before performing any maintenance on unit including filter inspection The input power to this unit is high voltage and touching any live electrical parts can cause fatal shocks or severe burns Do no...

Page 11: ...plication As Required Replace Filter 1 Replace Filter Every 12 months Inspect Basic Components 1 Clean unreadable labels and exterior surfaces 2 Capture Arm Check for tears in flex hoses and fitting o...

Page 12: ...Hood inlet Capture tubes Unit Operates Properly Call for Service 1 800 361 3733 support diversitech ca Call for Service 1 800 361 3733 support diversitech ca Call for Service 1 800 361 3733 support d...

Page 13: ...ansformer wiring may differ depending on voltage configuration Units in brackets refer to imperial system values 1 5 HP 120v TEFC Motor 60 Hz Disconnect power before performing any maintenance on unit...

Page 14: ...er wiring may differ depending on voltage configuration Units in brackets refer to imperial system values 3HP 230 460 575v TEFC Motor 3600 RPM 60 Hz Disconnect power before performing any maintenance...

Page 15: ...CH INC MODEL N FRED SR SERIAL N SERVICE LOCATION CONTROL N 15 Only use manufacturer approved replacement parts on this unit Diversitech Inc authorizes this page to be photocopied or otherwise reproduc...

Page 16: ...Vent Hood STEP 1 Unpack capture arm hood and base STEP 2 Attach swivel base to mounting plate APPENDIX 3 ARM TO BLOWER DIRECT INSTALLATION 3 1 Unpack capture arm hood and base 3 2 Attach swivel base t...

Page 17: ...ture arm to swivel base STEP 3 Attach capture arm to swivel base Insert Spacers 3 between Capture Arm Mounting Bracket Thread Bolts 3 with Washers 3 through Mounting Bracket and Spacers Mount Capture...

Page 18: ...Quantity Hardware 1 Fred SR Assembly 2 Hose Clamps 1 Flex Hose 18 STEP 4 Install flex hose 3 4 Install flex hose Mount Flex Hose to Swivel Base and Capture Arm Tighten Both Hose Clamps...

Page 19: ...p 8 1 4 Washer Quantity Hardware 1 Swivel Base 1 J Bracket 3 1 4 Bolt Socket Cap 6 1 4 Washer 3 1 4 Lock Nut Socket Cap Mount J Bracket to Swivel Base Tighten all Bolts 8 with Washers 8 and Nuts 3 Toq...

Page 20: ...ssembly 2 Hose Clamps 1 Flex Hose Mount Flex Hose to Swivel Base and capture Arm Tighten Both Hose Clamps STEP 5 Install Flex Hose 4 5 Install Flex Hose Insert J Bracket between Capture Arm Mounting B...

Page 21: ...TICKERS The machine is marked with a wet filtration safety sticker to remind the operator of safe working practices The machine is marked with safety stickers in appropriate places to remind the opera...

Page 22: ...22 NOTES...

Page 23: ...NOTES 23...

Page 24: ...se or use above rated capacities FREIGHT CLAIMS Shipments must be inspected upon arrival All Diversitech units are sold ex plant Therefore it is the receiver s responsibility to file any freight claim...

Reviews: