background image

For domestic household use only.

INSTRUCTION MANUAL

Air Circulator Fan

Model: DCAC30HC

08/55014/0 Issue 3

Summary of Contents for DCAC30HC

Page 1: ...For domestic household use only INSTRUCTION MANUAL Air Circulator Fan Model DCAC30HC 08 55014 0 Issue 3 ...

Page 2: ... and cause burns Particular attention has to be given where children and vulnerable people are present If the supply cord is damaged it must only be replaced by the manufacturers service agent or a similarly qualified person in order to avoid a hazard This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and ...

Page 3: ...here are visible signs of damage to the heater The heater must not be located immediately below a power outlet WARNING To avoid danger of suffocation please remove all packaging materials particularly plastic and EPS and keep these away from vulnerable people children and babies NEVER drop or insert any object or fingers into any openings Do not use the appliance in locations where paint petrol or...

Page 4: ... Unfortunately it is not obvious when a button or coin battery is stuck in a child s oesophagus food pipe There are no specific symptoms associated with this The child might cough gag or drool a lot appear to have a stomach upset or virus be sick point to their throat or stomach have a pain in their abdomen chest or throat be tired or lethargic be quieter or more clingy than usual or otherwise not...

Page 5: ...extension leads or power boards Where there is risk of fire or close to a naked flame Where the power cable may be damaged On a slope or uneven surface Where it may be damaged by chemicals If there is a risk of water falling on the unit Where there is a risk of interference by foreign objects This product is not made for DIY repair 5 ...

Page 6: ...ling Heat settings 2 Timer 12 hours Air movement 15m3 min Air speed 6m s Vertical oscillation 70o Horizontal oscillation 80o Noise level MAX 55dB A Weight net 3 9kg Dimensions w x d x h 318 x 275 x 404 2mm Specification For greater precision please always refer to the rating label placed on the product 6 ...

Page 7: ...e air with fresh air from an open window Air circulators are the safe all year round temperature regulation solution you ve been looking for Where To Position During Summer pointing the air circulator towards a wall halfway between the floor and the ceiling as well as using the highest setting will set up a high speed air circulation pattern This will cool down the room in an efficient manner Poin...

Page 8: ...ront Shell 2 Front Grille 3 Cover 4 Post 5 PC Panel 6 Upper Base Cover 7 Lower Base Cover 8 RearShell 9 HandleCover 10 FixingBlock 11 Dust Screen Left 12 Dust Screen Right 13 Power Cord 14 Manual On Off Switch 8 ...

Page 9: ... 8 T emp TimerFunction 9 T emp TimerIncrease 10 LED Display 2 3 4 5 6 7 8 9 10 On Off button Timer increase decrease button Heating speed button Horizontal Oscillation button Display On Off button Temperature increase decrease button Cooling speed button Vertical Oscillation button To remove the cover of the remote remove the screw Be aware a small screw driver is needed for this action 9 ...

Page 10: ... warmer and more concentrated See Fig 1 below When in cooling mode we recommend pushing the handles backwards to open the air outlet This will make the air inlet volume larger and the noise will be significantly reduced See Fig 2 below Pull forward Push back Heating mode Please pull both left right handle cover forward As shown in the figure Cooling mode Please push both left right handle cover bac...

Page 11: ...up Press this button 3 to switch the speed in the following sequence 1 2 3 4 5 1 etc The corresponding indicator LED lights up accordingly TIMER SETTING After pressing the Temp Timer Function button 8 the timer LED light comes on and the unit enters the timer setting function You can adjust the timer by pressing the 9 or 7 button to the desired working time The adjustment does not cycle The timer ...

Page 12: ...function Press it for the first time to turn on the low level heating air the low level heating indicator lights up and the low level heating air runs at level 2 speed b Press the Heating Air Speed button 4 again to turn on the high level heating air the high level heater indicator lights up and the high level heating wire switches on after 10 seconds when the high level heating air is turned on i...

Page 13: ...n are described as follows a The swing angle is 70 When switching directions the device first pauses for 2 seconds and then swings to the other direction b When the device is powered on for the first time the vertical oscillation function turns on the motor first finds the origin swings up 30 pauses 9 seconds swings down 70 pauses 15 seconds if the swing angle is not 30 or 70 the motor still needs...

Page 14: ...screen on the left and right sides and then take out the filter for cleaning 4 Wipe the surface of the unit with a soft damp cloth Mild detergent can be used for any stubborn marks IMPORTANT The control panel and other parts must not come into contact with water or any other liquids Storage If not using the unit for an extended period of time After cleaning please Turn the unit off unplug and take...

Page 15: ...formation regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the ground water polluting the food chain and damaging health and well being Warranty Please refer to the warranty card in the box for warranty information For any troubleshooting advice please contact the relative Customer Care Centre below Glen Di...

Page 16: ... Supplied by Glen Dimplex Australia 8 Lakeview Drive Scoresby Victoria 3179 Glen Dimplex Australia All rights reserved Material contained in this publication may not be reproduced in whole or in part without prior permission in writing of Glen Dimplex Australia DCAC30HC REV 3 16 ...

Reviews: