background image

Installation Manual

❖Accessories

Bracket for machine
Electrical cable

Emergency cable
Air hose

Air regulator
Bolts
①for the bracket
②for the machine
③pass line adjusting

④Bonding

Mark tube, Terminal

Sticker

Air connector
⑤Apron plate

❖Method of Input

Power

Turn on "Power" switch

Set ⇔ Run

You can input a set value  when "Set" lamp is lit.

Numeric value that can be changed item or number will be blink.

+/-  

Using the switches, you can change the value.

If you need to continue inputting, repeat the ③, ④.

After setting

Set ⇔ Run

Sync

Sync

Feed

Release

Usually, the Release mode does not display.

Press the both switches of  Sync Feed and
Sync Release switches, then the controller will
be able to receive the sync press cam signals.

Signal(Feed/Release), Scale for
pass line(on the bracket)

1-TS8-03, 2-NTS8-02

Only when changing settings item, the Release mode is supposed to display on the
"Feed Length" after displaying digit of lowest of "Feed Length"

← → 

Using the switches, you can move the cursor position.

Push "Set ⇔ Run" switch, when "Run" lamp is lit, the setting
finishes.

Exclusive type

DIMAC

Model J06

8*5:6M

2-M12*30

Exclusive type

Description of good

J06

4-M8*15

1-M12*120

Net 4ml

Assortment

P6:8M

8M

Fixture for the air regulator

With air filter

2-M6*12

1

Summary of Contents for J06

Page 1: ...nc Feed Release Usually the Release mode does not display Press the both switches of Sync Feed and Sync Release switches then the controller will be able to receive the sync press cam signals Signal Feed Release Scale for pass line on the bracket 1 TS8 03 2 NTS8 02 Only when changing settings item the Release mode is supposed to display on the Feed Length after displaying digit of lowest of Feed L...

Page 2: ...nting position Top view Mounting position 2 6 3 7 4 8 5 9 1 not use a h for J15 h g f e d c b a J06 70 Balance of confirmation Assembly drawing of the bracket 88 138 100 h Bolster 153 203 173 223 58 108 128 178 63 113 48 98 78 128 Bolster 9 8 7 6 5 4 3 2 1 h 75 h 100 178 228 108 158 73 123 98 148 133 183 158 208 h 0 h 25 h 50 113 163 188 238 138 188 123 173 148 198 h 125 33 83 203 253 163 213 CAUT...

Page 3: ...GER To cover each cable which is not using connection CAUTION Yellow Press cont processing Need to short if not using Need to short the circuit of press processing select S5 S6 if you don t use the circuit To the stop continuous on the press circuit Work shortage sensor output To the stop continuous on the press circuit Continuous stop signal output To the stop continuous on the press circuit Red ...

Page 4: ...side the connecting cover Connecting cover Air piping TS8 03 NTS8 02 To solenoid valve Approximate air pressure 0 3 0 5 MPa Maximum air pressure 0 5 MPa NTS8 02 Air passes in specific direction CAUTION DANGER Need to fix three external cables in prepared nylon band 4 ...

Page 5: ...he press cam signal Release timer setting It can be input from 0 001sec to 0 05 sec Input time period the release carry out Input the release strat using the press cam signal The delay time will vary depending in the springs pressure NOTE Need to set the ON of the feed signal to the feed completed angles when using option Overrun Function Set the ON to the release start angle and set the OFF to th...

Page 6: ...nsor Setting mistake Motor connection anomaly Initial setting mistake Contact failure Number State Content Note Setting mistake of the motor capacity J06 After releasing the Emergency stop switch turn off the power Model number ENG STOP Turn on Sync Feed and Sync Release after turn on Reset switch Turning off Sync Feed the work shortage sensor will disabled I F 7 7 7 7 7 7 666666 Contents CC When ...