background image

  Digi-Pas

 

 

 

    

Innovation & Technology Driven

 

 

USER MANUAL 

 

2-Axis Precision Digital Level 

Model: DWL3000XY  

 

 
 
 
 
 

 

 

www.digipas.com

   

 

 

 

 

 

 

           

REVISION 4.40

 

 
 

Note: Contents in this instruction manual is continuously updated, please check Digi-Pas website for latest version. 

Please  take  note  that  the  device  contains 

STRONG MAGNET!

 

® 

Summary of Contents for DWL3000XY

Page 1: ...AL 2 Axis Precision Digital Level Model DWL3000XY www digipas com REVISION 4 40 Note Contents in this instruction manual is continuously updated please check Digi Pas website for latest version Please take note that the device contains STRONG MAGNET ...

Page 2: ...tion which is protected by copyrights All rights are reserved No part of this manual may be photocopied reproduced redistributed or translated to another language without prior written consent of JSB TECH Company The information in this manual was correct at the time of printing stored in CD or uploaded in the Company website However JSB TECH will continue to improve products and reserves the righ...

Page 3: ...ING UP Operating Procedure Mounting Device on Fixture CHAPTER 3 USER INTERFACE Single Axis Mode Interface Dual Axis Mode Interface Main Menu Icon Functions CHAPTER 4 FEATURES AND SETTING Absolute Level Alternate Zero Sync Menu Angle Meter Vibro Meter Setting Menu CHAPTER 5 STORAGE AND CLEANING CHAPTER 6 WARRANTY APPENDIX USER CALIBRATION ...

Page 4: ... 2 0 Cable 5 metre Bluetooth 30 metre Optional PC SYNC Software Basic Edition Professional Edition Optional Operating Temperature 10 C to 50 C Calibrated 14 F to 122 F Calibrated Dimension mm 188 x 62 x 37 Nett Weight Approx 580 gram User Self Calibration Yes Specifications are subject to change without notice Alternative Device power can be obtained from External USB Power Source Note Product per...

Page 5: ...nd display mode Selection the function UNIT Change the unit degree mm M In FT of the measurement Scroll left Buzzer sound alert LCD Colour graphic digital display Battery Compartment of 4 x AAA size 1 5V batteries Observe the polarity of the batteries indicated on the top of the battery cover ON OFF Power On Off Escape from Mode function Aluminium base contain STRONG MAGNET to securely hold on to ...

Page 6: ...1 set 3 AAA batteries 4 pcs 4 USB 2 0 cable 3 Meters 1 pc 5 Basic PC Sync Software 1 pc 6 M5 Domed screw 3 pcs ii List of items included in DWL 3000XY Bluetooth version product package Item No Description Quantity 1 DWL 3000XY Precision Digital Level with Vibrometer Bluetooth version 1 unit 2 Certificate of Calibration 1 set 3 AAA batteries 4 pcs 4 USB 2 0 cable 3 Meters 1 pc 5 Basic PC Sync Softw...

Page 7: ...ce 3 Device ready to use Note For maximum accuracy perform calibration refer to APPENDIX User Calibration or Absolute Level refer to Chapter 4 Absolute Level for more details before measurement Mounting Device On Fixture or Work Piece The two threaded holes are provided for mounting the device onto user defined fixtures machinery To mount the device onto user s defined fixture or work piece Remove...

Page 8: ...asured Please ensure the contact surfaces of the device and measuring plane are clean and free from dust particles The green arrow sign on display indicates the higher side User may freeze the screen by pressing the HOLD button The icon pops up to indicate the screen is paused To resume operation press the hold button once OFF HOLD MAIN MENU MEASUREMENT UNITS MEASUREMENT UNITS BATTERY LEVEL DIGITA...

Page 9: ...nd measuring plane are clean and free from dust particles The Target Ball or Bull Eye move towards the measured position similar to traditional Bubble vials The green arrow sign on display indicates the higher side of plane Once the measurement stabilizes the Target Ball or Bull Eye blinks BATTERY LEVEL MEASUREMENT UNITS MICROMETER VERTICAL Y AXIS DIGITAL READING HORIZONTAL X AXIS DIGITAL READING ...

Page 10: ...OLUTE LEVEL SETTING Enable user to ensure each measurement reading is in accordance to maximum device accuracy specified ALTERNATE ZERO SETTING Enable user to measure relative angles at a common plane with respect to a reference angle Set any angle to 0 00 as a reference TITLES CURSOR ICONS ICONS CURSOR TITLES EXIT MAIN MENU SCROLL RIGHT SELECT ENTER SCROLL LEFT ...

Page 11: ...METER Enables user to obtain real time continuous angle measurements displayed in line graph VIBRO METER Enables user to obtain real time continuous vibration measurements displayed in line graph SETTING MENU Enable user to modify various parameters of the device HELP MENU Enable user to have a quick and easy reference on Device s button configuration For DWL3000XY Bluetooth device the HELP icon i...

Page 12: ... full Please ensure the contact surfaces of the device and measuring plane are clean and free from dust particles Note The device is able to auto detect its position is single axis position or dual axis Turn the device 180 and press MODE button again to start the measurement When completed the above settings the logo is shown to indicate that the device is in the Absolute Level mode BACK TO MAIN M...

Page 13: ...ree from dust particles Note The device is able to auto detect its position is single axis position or 2 axis Single Axis Position The logo is shown to indicate that the device is in Alternate Zero mode A reference line is displayed to indicate the angle Dual Axis Position The logo is shown to indicate the device is in the Alternate Zero mode A reference crosshair is displayed to indicate the real...

Page 14: ...scroll the right button and then press MODE button Reboot the device by turning off the device and then turn on the device again to activate the new setting Once Bluetooth mode is activated the icon will display on the single and dual axis mode screen display BACK TO MAIN MENU MOVE TO RIGHT SELECT ENTER MOVE TO LEFT SYNC via USB SYNC via Bluetooth Cursor Status USB Active Current Status ...

Page 15: ...device and measuring plane are clean and free from dust particles The Angle Meter displays real time continuous angle measurements in line graph User may freeze the screen by pressing the HOLD button The icon pops up to indicate the screen is paused To resume operation press the hold button once BACK TO MAIN MENU HOLD SELECT ENTER MEASUREMNT UNIT BATTERY LEVEL HORIZONTAL DIGITAL READING Time Secon...

Page 16: ...ce and measuring plane are clean and free from dust particles When the device detect the vibration the relative magnitude g is shown on the graph To change the scale and speed of the line graph press the scale selection button or the speed selection button accordingly SPEED OF DATA ACQUISITION BATTERY LEVEL BACK TO PREVIOUS MENU HOLD SCALE SELECTION ZOOM MENU ZOOM MENU TO SCALE MAGNITUDE TIME S ZO...

Page 17: ...ding to user defined time period Auto Dim To set automatic dim according to user defined time period Units To change the measuring unit Degree mm M In FT Buzzer To turn on off the device buzzer Display Brightness To set LCD brightness according to user defined level SETTING PARAMETERS MAIN MENU RIGHT SELECTION DOWN LEFT SELECTION ...

Page 18: ... C or 4 F to 140 F When the device is not in used the batteries are to be removed from the device Cleaning 1 Keep the device dry and clean Remove any moisture or dirt with a soft dry cloth before measurement to obtain the maximum accuracy Do not use harsh chemicals strong detergents or cleaning solvent to clean the device 2 Do not submerge device in liquid while cleaning ...

Page 19: ...pose Limitation of Liability In no event shall DIGIPAS USA LLC hereinafter the Company be liable to you or any third party for any indirect special incidental exemplary or consequential damages of any kind resulting from any breach of warranty or from the performance or use of the product This includes without limitation property damage loss of value of the product or any third party products that...

Page 20: ...180 to Position 2 Press the MODE button again to start the calibration at Position 2 and wait until the countdown reach 0 the LCD screen displays Calibration 3 3 Place the device 90 on the side of Master Square as shown in Position 3 Hold the device firmly and do not move the device during each count down period Press the MODE button again to start the calibration and wait until the countdown reac...

Page 21: ...vice during each count down period Press the MODE button again to start the calibration and wait until the countdown reach 0 the LCD screen displays Calibration 6 6 Turn the device 180 and place on the opposite side of the master square as shown in Position 6 Hold the device firmly and do not move the device during each count down period Press the MODE button again to start the calibration and wai...

Reviews: