manualshive.com logo in svg
background image

 

 
 

 
 
 

 

BEETLE /iSCAN EASY eXpress

+

 

Self-Checkout System 

 
 
 
 
 
 
 
 
 
 
 

Integration Manual (January 2018) 

Содержание BEETLE/iSCAN EASY eXpress Plus

Страница 1: ...BEETLE iSCAN EASY eXpress Self Checkout System Integration Manual January 2018...

Страница 2: ...xdorf International GmbH 2018 All rights including rights to full or partial translation reprinting and transmission or copying by any means are reserved Offenders are liable to payment of damages All...

Страница 3: ...eXpress 16 9 1 4 Pole with 19 BEETLE iScan EASY eXpress and optional basket shelves on both sides pole light coupon box and bottom plate 16 9 1 5 Pole with 19 BEETLE iScan EASY eXpress and optinal bas...

Страница 4: ......

Страница 5: ...n Manual 1 1 Notes Find further informations in the BEETLE iSCAN Express installation manual on the Diebold Nixdorf Internets Use an angled power cord when installing the unit in the table adapter or...

Страница 6: ...g m3 85 r h 25 g m3 Temperature change 0 5 K min max 7 5K 30 min Barometric pressure 70 kPa 106 kPa 70kPa corresponds to an installation at approximately 2000 meters above sea level Installa tion env...

Страница 7: ...BEETLE iSCAN EASY eXpress Integration Manual 3 3 Dimensions mm 3 1 Back Side 15 and 19 Version...

Страница 8: ...Integration Manual BEETLE iSCAN EASY eXpress 4 3 2 15 Version...

Страница 9: ...BEETLE iSCAN EASY eXpress Integration Manual 5 3 3 15 Version with Table Stand...

Страница 10: ...Integration Manual BEETLE iSCAN EASY eXpress 6 3 4 19 Version 3 5 19 Version with table Stand...

Страница 11: ...BEETLE iSCAN EASY eXpress Integration Manual 7 3 6 Bottom side 3 7 Device with open door Service area...

Страница 12: ...ss may be installed vertically or at an angle of up to 23 from the ver tical Danger of entering liquids When mounted vertically in a restaurant environment a suitable device must be used to prevent dr...

Страница 13: ...ngs of the unit free to ensure good ventilation This avoids excessive tem perature rise Even if you want to install the device it is imperative that you maintain the minimum distances indi cated below...

Страница 14: ...Y eXpress 10 Observe the specified minimum clearances for reliable ventilation Always keep the ventilation slots clear of obstructions to ensure proper air circulation and prevent overheating 15 Versi...

Страница 15: ...iSCAN EASY eXpress Integration Manual 11 6 System suspension 4 positions for fastening with screws with a diameter of 6mm 4 positions for fas tening with hook a additional fixation with screws is nec...

Страница 16: ...de of the device there is an opening on the right and left side which is closed by covers One of the apertures allows cable entry with edge protection The apertures can be exchanged for each other Cov...

Страница 17: ...ons such as holders for hand held scanners advertising media etc on both sides of the body When installing it is important to ensure that the opening of the door and access to the locking system are n...

Страница 18: ...Integration Manual BEETLE iSCAN EASY eXpress 14...

Страница 19: ...BEETLE iSCAN EASY eXpress Integration Manual 15 9 Pole and Wall mounting 9 1 Dimensions 9 1 1 Optional bottom plate 9 1 2 Pole bottom hole pattern...

Страница 20: ...on Manual BEETLE iSCAN EASY eXpress 16 9 1 3 Pole with 15 BEETLE iScan EASY eXpress 9 1 4 Pole with 19 BEETLE iScan EASY eXpress and optional basket shelves on both sides pole light coupon box and bot...

Страница 21: ...BEETLE iSCAN EASY eXpress Integration Manual 17 9 1 5 Pole with 19 BEETLE iScan EASY eXpress and optinal basket scale front 9 1 6 Wallmount with 15 BEETLE iScan EASY eXpress...

Страница 22: ...Integration Manual BEETLE iSCAN EASY eXpress 18 9 1 7 Wallmount with 19 BEETLE iScan EASY eXpress...

Страница 23: ...t by a trained technician after the assessment and evaluation of the constructional conditions on site Mounting kit contains 4x impact anchor M10 4x hexagon head screw DIN 933 M10x60 8 8 4x washer 10...

Страница 24: ...be on solid ground 4 Mark the 4 holes as bearing points Do not mark or drill bearing points on the floor cable outlet Caution The kiosk needs to be screwed to the floor to avoid the kiosk to tip over...

Страница 25: ...through the opening in the base plate posi tioned above the floor cable out let Now align the base plate in the position over the drilled holes with the dowels Fix the pole securely to the ground wit...

Страница 26: ...is on the pole by placing the openings in the housing onto the hooks and the upper screws of the pole 1 Then unlock the sys tem and open the door Then screw in the missing two M6x10 pan head screws 2...

Страница 27: ...cables into the housing of the EASY eXpress and secure them with cable ties like cable tie PLP1 5S M to the pole on the inside hole pattern For connection of the cables to the EASY eXpress please see...

Страница 28: ...r M10 4x hexagon head screw DIN 933 M10x60 8 8 4x washer 10 5x2 0 1 Position the bottom plate above the floor cable outlet ensuring that cables can be guided through the hole in the middle of the bott...

Страница 29: ...be screwed to the floor to avoid un wanted moving on e g flat surfaces Drill the 4 holes use a 12mm rock drill into the floor ground and insert the impact anchors Make sure that the depth of the bear...

Страница 30: ...se plate in the position over the drilled holes with the dowels Fix the pole securely to the ground with hexa gon head screws M10x60 8 8 Follow steps 6 10 of previous chapter 9 3 Self Checkout with ov...

Страница 31: ...BEETLE iSCAN EASY eXpress Integration Manual 27 Slide all necessary cables power cable LAN cable etc through the opening at the bottom of the pole Follow step 7 10 of chapter 12 1...

Страница 32: ...ditions on site For the integration of the BEETLE iScan EASY eXpress in the wallmount 2 persons are required The wearing of safety shoes is obligatory 9 4 2 Hole pattern for wallmount dimensions in mm...

Страница 33: ...rough the key holes and push it down to align all 4 holes in the wallmount to the dowels in the wall Screw in the two missing screws at the upper end of the wallmount and tighten all four screws secur...

Страница 34: ...LE iScan EASY eXpress in the wallmount and push it to the top end first and then let it slide down till it sits on the hooks and the both screws of the wallmount Open the BEETLE iScan EASY eXpress and...

Страница 35: ...BEETLE iSCAN EASY eXpress Integration Manual 31 10 Block diagram Optional components are marked green...

Страница 36: ......

Страница 37: ...Diebold Nixdorf D 33094 Paderborn Order No 01750301911A...

Отзывы: