GETTING STARTED

GETTING STARTED

GETTING STARTED

GETTING STARTED    
7-day chart rotation 
0 to 100

o

F  

 
QUICK START

QUICK START

QUICK START

QUICK START    

1.

1.

1.

1.

 

Remove the protective pen cap(s). 
 

2.

2.

2.

2.

 

Connect Probe(s): 

a.

 

KT8P0/2/3: Make sure the KTC probe is connected firmly to the Replaceable 
Sensor and that the Replaceable Sensor is plugged in firmly to the chart recorder.  

b.

 

KT856: Make sure both KTC probes are plugged in firmly to the chart recorder. 
 

3.

3.

3.

3.

 

Insert batteries and plug in AC adapter (See Figure 3).  KT8P0:4 AA batteries required; 
KT8P2/3 & KT856: 4 AA batteries backup power only (See page 5 for backup life).  Unit 
will power on. 

 

4.

4.

4.

4.

 

The instrument will move pen(s) to the appropriate readings. 

 

5.

5.

5.

5.

 

Install the chart that matches the Dip Switch settings (See p.4). 
 
Press the PEN

PEN

PEN

PEN    HOME

HOME

HOME

HOME key to move the pen(s) to the outside of the chart.  The pen(s) is 

automatically raised off the chart. 
 
Remove the old chart, place the new chart on the Chart Hub being certain that the edge 
of the chart slides under the Chart Guide Clips located at the outside of the chart. 
 

6.

6.

6.

6.

 

Set the appropriate time.  There are two ways to adjust the chart and set the appropriate 
time: 

 

a.

 

Set the chart time manually by inserting a coin into the groove in the chart hub 
and turning clockwise until the correct hour (and day if applicable) on the chart is 
referenced to the timing arrow (just to the right of the pen tip on the dial).  Press 
Pen

Pen

Pen

Pen    Home

Home

Home

Home to move the pen(s) back onto the chart. 

 

The following feature should be used for fine adjustments only. 

 
b.

 

To adjust the chart time, press and hold Adjust

Adjust

Adjust

Adjust----Up

Up

Up

Up and Adjust

Adjust

Adjust

Adjust----Down

Down

Down

Down buttons 

located on the back of the unit next to the dip switch (see Figure 3). 

 

The green LED will blink rapidly for about five seconds, then the LED will remain 
solid green.  While in this state the Adjust

Adjust

Adjust

Adjust----Up

Up

Up

Up button will move the chart 

backward (counter clockwise) and the Adjust

Adjust

Adjust

Adjust----Down

Down

Down

Down button will move the chart 

forward (clockwise). 
 
Rotate the chart until the correct hour (and day if applicable) on the chart is 
referenced to the timing arrow.  Once you have set your chart, press the Pen 

Pen 

Pen 

Pen 

Home 

Home 

Home 

Home button to exit Chart Adjust Mode.  The unit will take one minute to exit the 
Chart Adjust Mode once Pen

Pen

Pen

Pen    Home

Home

Home

Home is pressed.  Press Pen

Pen

Pen

Pen    Home

Home

Home

Home to move the 

pen(s) back onto the chart. 
 

c.

 

Place the KT8 recorder on a flat vibration-free surface.  Be sure it is in a vertical 
position and level.  For best performance and longevity, the location should be a 
clean environment, free from dust and corrosive fumes.  Do not exceed 
temperature specifications.  Wall Mount:

Wall Mount:

Wall Mount:

Wall Mount:  Keyhole slots are provided on the KT8 

recorder for wall mounting. 

 

Summary of Contents for KT8P0

Page 1: ...t time manually by inserting a coin into the groove in the chart hub and turning clockwise until the correct hour and day if applicable on the chart is referenced to the timing arrow just to the right of the pen tip on the dial Press Pen Pen Pen Pen Home Home Home Home to move the pen s back onto the chart The following feature should be used for fine adjustments only b To adjust the chart time pr...

Page 2: ... the pen s are located on the outside edge of the chart press the Pen Pen Pen Pen Home Home Home Home to move pen s to recording position If the pen s are located on the chart press the Pen Pen Pen Pen Home Home Home Home key to move the pen s to the outside edge of the chart A A A Alarm larm larm larm Optional Optional Optional Optional Pen 1 Red Pen Pen 2 Blue Pen F Channel Indicator Low Battery...

Page 3: ...en Pen Pen Home Home Home Home button will scroll through the five options until the A A A Alarm larm larm larm button is pressed to exit from alarm adjust Each press of the Pe Pe Pe Pen n n n Home Home Home Home or Alarm Alarm Alarm Alarm button will store the new settings The unit will take one minute to exit Alarm Set Mode once the Alarm Alarm Alarm Alarm button is pressed 4 4 4 4 If the alarm ...

Page 4: ...ng Time 1 down 2 up 1 down 2 down 1 up 2 up o F 3 down o C 3 up Temperature Ranges Temperature Ranges Temperature Ranges Temperature Ranges 4 down 5 down 6 down 4 down 5 down 6 up 4 down 5 up 6 up 4 up 5 down 6 down 4 down 5 up 6 down 4 up 5 up 6 up 4 up 5 down 6 up 4 up 5 up 6 down All the KT8 recorders feature usre selectable recording times Note Remember to install the correct chart to match co...

Page 5: ...n Home Pen Home Pen Home Pen Home and On Off On Off On Off On Off buttons until the LED is solid green Release the Pen Home Pen Home Pen Home Pen Home and On Off On Off On Off On Off buttons The LED will flash amber and green for one second then the LED will turn off Note Note Note Note Press Pen Home Pen Home Pen Home Pen Home first so the unit will not turn off 2 The pen s will move to the outer...

Page 6: ...T856 calibration can be adjusted at one point This will not adjust the span and is not as accurate as replacing the Replaceable Sensor with a newly calibrated one or returning the KT856 for recalibration 1 To activate Calibration mode turn the unit on and press and hold both the On Off On Off On Off On Off and the Adjust Adjust Adjust Adjust Down Down Down Down button until the LED is solid green ...

Page 7: ...her range or vice versa Pen s not inserted on pen arm s all the way To adjust pen s to match chart see Pen Home Adjust in the Need to Know section of this manual Why does the display read PROB Why does the display read PROB Why does the display read PROB Why does the display read PROB Check the sensor pod and KTC probe s Make sure it is properly plugged into the unit Is the unit locked up This can...

Page 8: ...l number serial number and a PO number ready before calling Replaceable Sensor Certificate of Validation Replaceable Sensor Certificate of Validation Replaceable Sensor Certificate of Validation Replaceable Sensor Certificate of Validation Dickson ensures that the Replaceable Sensors Instruments listed below were developed tested and validated together Replaceable Sensor Model R400 Instrument Mode...

Reviews: